Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
Gastrointest Endosc ; 75(2): 254-60, 2012 Feb.
Article in English | MEDLINE | ID: mdl-22153875

ABSTRACT

BACKGROUND: Training simulators have been used for decades with success; however, a standardized educational strategy for diagnostic EGD is still lacking. OBJECTIVE: Development of a training strategy for diagnostic upper endoscopy. STUDY DESIGN: Prospective, randomized trial. SETTINGS: A total of 28 medical and surgical residents without endoscopic experience were enrolled. Basic skills evaluations were performed following a structured program involving theoretical lectures and a hands-on course in diagnostic EGD. Subsequently, stratified randomization to clinical plus simulator training (group 1, n = 10), clinical training only (group 2, n = 9), or simulator training only (group 3, n = 9) was performed. Ten sessions of simulator training were conducted for groups 1 and 3 during the 4-month program. Group 2 underwent standard training in endoscopy without supplemental simulator training. The final evaluation was performed on the simulator and by observation of 3 clinical cases. Skills and procedural times were recorded by blinded and unblinded evaluators. MAIN OUTCOME MEASUREMENTS: Time to reach the duodenum, pylorus, or esophagus. RESULTS: All trainees demonstrated a significant reduction in procedure time during a simple manual skills test (P < .05) and significantly better skills scores (P = .006, P = .042 and P = .017) in the simulator independent of the training strategy. Group 1 showed shorter times to intubate the esophagus (61 ± 26 seconds vs 85 ± 30 seconds and 95 ± 36 seconds) and the pylorus (183 ± 65 seconds vs 207 ± 61 seconds and 247 ± 66 seconds) during the clinical evaluation. Blinded assessment of EGD skills showed significantly better results for group 1 compared with group 3. Blinded and unblinded evaluations were not statistically different. LIMITATIONS: Small sample size. CONCLUSIONS: Structured simulator training supplementing clinical training in upper endoscopy appears to be superior to clinical training alone. Simulator training alone does not seem to be sufficient to improve endoscopic skills.


Subject(s)
Computer Simulation , Endoscopy, Digestive System/education , Gastroenterology/education , Internship and Residency , Clinical Competence , Fellowships and Scholarships , Humans , Internship and Residency/methods , Learning Curve , Motor Skills , Prospective Studies , Time Factors
2.
Med Sci Monit ; 17(1): MT1-6, 2011 Jan.
Article in English | MEDLINE | ID: mdl-21169916

ABSTRACT

BACKGROUND: Hemoclip application in GI-hemorrhage has proven to be effective. Clinical experience shows that multiple clips are frequently necessary. In 2005, an easily reloadable clip-applicator was introduced. We evaluated the hemodynamic efficacy of this new device. MATERIAL/METHODS: We prospectively compared the new clipping device (Olympus HX 110/610) in a validated experimental setting using the compactEASIE®-simulator for GI bleeding. The artificial blood circulation system in the simulator was connected to a pressure transducer. Four investigators of different endoscopic experience (1000-6000 endoscopies) treated 12 bleeding sources each, with up to 6 clips for each bleeding location. Pressures were recorded to objectify the additive effects of sequential clip application on the reduction in vessel diameter. The intervention was abandoned if a maximum measurable pressure of 300 mmHg was achieved. RESULTS: Hemoclip application led to a significant increase of peak pressure (91±100 mmHg, p<0.001) and mean pressure (95±99 mmHg, p<0.001), representing a significant reduction in vessel diameter. Pooled data showed a significant stepwise increase in mean and maximum system pressure, resulting in reduction of vessel diameter up to the fifth hemoclip. On average, 5 clips (range 1-6) were used. More experienced endoscopists achieved a higher increase in mean pressure (167 and 118 mmHg vs 72 and 23 mmHg, p<0.05). Mean reloading time was 39 seconds (19-49 sec). CONCLUSIONS: Sequential application of multiple hemoclips led to an increasing effect, comparable to the results of previous clinical trials. The number of hemoclips applied correlated inversely, but not significantly, with the endoscopist´s experience. Expensive single-use clips appear dispensable in view of the short reloading time.


Subject(s)
Endoscopy, Gastrointestinal/instrumentation , Gastrointestinal Hemorrhage/therapy , Hemostatic Techniques/instrumentation , Animals , Blood Pressure , Endoscopy, Gastrointestinal/methods , Humans , Prospective Studies , Sus scrofa
SELECTION OF CITATIONS
SEARCH DETAIL