Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Ulus Travma Acil Cerrahi Derg ; 29(8): 920-928, 2023 Aug.
Article in English | MEDLINE | ID: mdl-37563900

ABSTRACT

BACKGROUND: Ankle sprain is a frequent reason for presentation to the emergency department. Current treatment modalities include Protection, Optimal Loading, Ice, Compression, and Elevation (POLICE) and Protection, Rest, Ice, Compression, and Elevation (PRICE). This study aimed to compare the effects of PRICE and POLICE treatment protocols. METHODS: This randomized controlled study was conducted between October 15, 2020, and October 15, 2021, at Ankara University's Department of Emergency Medicine. Double-blind randomization was used to assign patients to either the POLICE or PRICE treatment groups. RESULTS: In total, 109 patients were included. In the POLICE group, the median difference between the American Orthopedic Foot and Ankle Scores on admission and the 14th day following the injury was 34.5 (IQR: 27.25-41.75), while that of the PRICE group was 24 (IQR: 15.5-35). In the POLICE group, the median value of the difference in the Foot and Ankle Disability Index scores on admission and the 14th day following the injury was 42 (IQR: 35.25-50), while that of the PRICE group was 31 (IQR: 22-41.5). CONCLUSION: The POLICE treatment protocol provided more effective and faster recovery than the PRICE treatment protocol.


Subject(s)
Ankle Injuries , Sprains and Strains , Humans , Ankle , Ice , Police , Clinical Protocols , Randomized Controlled Trials as Topic
2.
Heliyon ; 8(9): e10553, 2022 Sep.
Article in English | MEDLINE | ID: mdl-36119864

ABSTRACT

Objectives: Second victim experience defines the healthcare professionals involved in unexpected adverse patient events. The Second Victim Experience and Support Tool (SVEST) is a tool used to measure the second victim experience and the desired support resources. This study aims to carry out a cross-cultural adaptation of the SVEST and to evaluate the psychometric properties of the Turkish version (T-SVEST). Methods: The T-SVEST was translated and adapted according to World Health Organization guidelines. 221 healthcare professionals including physicians, residents and nurses working at the emergency department, completed the survey. â€‹Cronbach's â€‹α â€‹values were assessed for reliability, and construct validity was assessed through confirmatory factor analysis in order to evaluate model fit. Results: The global Cronbach's α score of the T-SVEST was 0.90. The final version of the TSVEST including 24 items was consistent with values between 0.83 and 0.89. The most consistent dimension was turnover intentions with a Cronbach's value of 0.89, it was followed by institutional support (Cronbach α = 0.88). After applying modifications suggested by â€‹confirmatory factor analysis, a final model including 9 factor-structure (7 dimensions and 2 outcome variables) and 24 items was significantly improved with acceptable â€‹comparative fit index, â€‹Tucker-Lewis index â€‹and â€‹root mean square error of approximation. Conclusion: The Turkish version of the SVEST is a reliable and valid instrument that can be used to identify second victims and help implement support resources.

3.
Altern Ther Health Med ; 26(2): 62-64, 2020 Mar.
Article in English | MEDLINE | ID: mdl-31221937

ABSTRACT

CONTEXT: Trigger point injections (TPIs) and acupuncture are common procedures in management of chronic back pain and usually are considered safe. Needling into cervical and thoracic regions can be associated with life-threatening complications. OBJECTIVE: The team intended to make practitioners aware of the potential for hemopneumothorax after TPI. DESIGN: The research team describes a case of hemopneumothorax after TPI. SETTING: The case study took place in the Department of Emergency Medicine at the Ankara University School of Medicine (Ankara, Turkey). PARTICIPANT: The participant was a 45-y-old woman, who had been admitted to the emergency department at the School of Medicine with dyspnea and dizziness after TPI for fibromyalgia. RESULTS: Computerized tomography of the thorax showed a significant hemopneumothorax at the right hemithorax and a collapsed right lung, markedly in the right, lower lobe. The hemopneumothorax was successfully treated with chest-tube and video-assisted thoracoscopic surgery. CONCLUSIONS: Health care professionals need to be aware of hemopneumothorax when performing TPI on the chest wall.


Subject(s)
Dizziness/etiology , Dyspnea/etiology , Hemopneumothorax/diagnostic imaging , Lung/physiopathology , Tomography, X-Ray Computed/methods , Trigger Points , Dyspnea/surgery , Female , Fibromyalgia/drug therapy , Hemopneumothorax/etiology , Hemopneumothorax/surgery , Humans , Lung/diagnostic imaging , Middle Aged , Postoperative Complications/surgery , Thoracic Surgery, Video-Assisted , Treatment Outcome , Turkey
4.
Clin Anat ; 31(4): 593-597, 2018 May.
Article in English | MEDLINE | ID: mdl-28940706

ABSTRACT

Intraosseous access is a method for providing vascular access in resuscitation of critically ill and injured patients when traditional intravenous access is difficult or impossible. There is a lack of detailed description for the landmark for the insertion point in the literature. The aim of this study was to determine the exact location for intraosseous access. Radiographic computed tomography (CT) images of a total of 50 dry tibia bones were obtained. With 5-mm intervals, for all transverse images and by selecting transverse section, measurements were taken from the thickness of the cortex at anterior margin and mid-line medial surface, distance from anterior margin, and mid-line medial surface of the tibia to the posterior wall of medullar cavity, distance from anterior margin and mid-line medial surface of the tibia to the posterior surface of the tibia. The thinner part of the cortex of the tibia and the larger width of the medullar cavity is at 0.5 cm below the tibial tuberosity in the midline of the medial surface. The application region for proximal tibia access and landmark and most suitable insertion point for intraosseous infusion should be at level 0.5 cm below the tibial tuberosity in the midline of the medial surface. It was recommended that standard length for intraosseous canule should be 17 mm except for the thickness of skin. In conclusion, presented study provides certain localization for intraosseous access and standard length for intraosseous canule and this will be more effective in using this technique. Clin. Anat. 31:593-597, 2018. © 2017 Wiley Periodicals, Inc.


Subject(s)
Anatomic Landmarks/diagnostic imaging , Tibia/diagnostic imaging , Adult , Anatomic Landmarks/anatomy & histology , Anatomic Landmarks/surgery , Humans , Tibia/anatomy & histology , Tibia/surgery , Tomography, X-Ray Computed
5.
Am J Emerg Med ; 35(6): 855-859, 2017 Jun.
Article in English | MEDLINE | ID: mdl-28139307

ABSTRACT

STUDY OBJECTIVE: Our aim was to determine the efficiency of ultrasound (US) scanning in patients with wrist trauma admitted to the emergency department and to compare US diagnostic usage with other radiological imaging methods. METHODS: Patients who presented to the emergency department with wrist injury and who met the inclusion criteria and exclusion criteria were eligible. For all patients, US evaluation of the whole wrist was performed by an emergency physician before other radiological imaging methods (radiographies, computed tomography (CT) and magnetic resonance (MR) imaging). All of the patients included in the study underwent US, radiography, CT, and MR. RESULTS: During the study, 122 patients were admitted with a wrist injury. After filtering for the exclusion criteria, 80 patients were included in the study. The sensitivity of US scanning in detecting fractures was 95.31% (95% confidence interval [CI]: 87.1-98.39), the specificity was 93.75% (95% CI: 71.67-98.89), and the positive predictive value was 98.39% (95% CI: 91.72-99.85), and the negative predictive value was 83.33% (95% CI: 72.98-90.41). The sensitivity of US scanning in detecting tendon and ligamentous structural injury was 66.67% (95% CI: 41.71-84.82), the specificity was 100% (95% CI: 94.42-100), the positive predictive value was 100% (95% CI: 94.29-99.89), and the negative predictive was 92.86% (95% CI: 84.25-97.14). CONCLUSION: US scanning is an effective method that can be applied in the emergency department to adult patients to diagnose distal forearm and carpal bones fractures. In soft tissue injuries, US and MR examinations produce similar results.


Subject(s)
Fractures, Bone/diagnostic imaging , Point-of-Care Systems/statistics & numerical data , Ultrasonography , Wrist Injuries/diagnostic imaging , Adolescent , Adult , Aged , Aged, 80 and over , Cross-Sectional Studies , Emergency Service, Hospital , Female , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Tomography, X-Ray Computed , Turkey , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...