Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 14 de 14
Filter
2.
In Vivo ; 35(6): 3369-3375, 2021.
Article in English | MEDLINE | ID: mdl-34697171

ABSTRACT

BACKGROUND/AIM: Patients after kidney transplants are at risk of cardiovascular morbidity. An elevated resistance index (RI) is associated with renal graft failure, while a decreased RI can be due to a renal artery stenosis. The RI can also be measured in the carotid artery. Whether a correlation between intrarenal RI after kidney transplant in adult patients and the RI of the internal carotid artery exists is still unclear. PATIENTS AND METHODS: In this prospective cross-sectional study, RI of kidney transplants and of the internal carotid artery were measured with duplex sonography. Carotid intima-media thickness as well as the Framingham risk score and the Augmentation index, all known markers of atherosclerosis, were assessed. Correlations between the RI in Carotid artery and the RI of the kidney transplant were based on Spearmen test with the level of significance set at p<0.05. RESULTS: Ninety-eight consecutive patients [60% male, mean age of 48.7 (±15.6)] were included. The mean interval after transplantation was 27.5 (±8.5) months and mean serum creatinine was 308 (±220.3) mmol/ml The RI of the internal carotid artery and the renal transplant were significantly correlated (p<0.05). A correlation between the RIs and the Augmentation Index was found. CONCLUSION: The RI of the kidney transplant is correlated with the RI of the carotid artery and to markers of general atherosclerosis. This observation may be helpful to identify patients after kidney transplant with higher risk for cardiovascular events and gain indirect information on transplant renal artery stenosis.


Subject(s)
Atherosclerosis , Kidney Transplantation , Adult , Atherosclerosis/diagnostic imaging , Atherosclerosis/etiology , Carotid Intima-Media Thickness , Cross-Sectional Studies , Female , Humans , Kidney/diagnostic imaging , Kidney Transplantation/adverse effects , Male , Prospective Studies
3.
In Vivo ; 35(6): 3527-3535, 2021.
Article in English | MEDLINE | ID: mdl-34697191

ABSTRACT

BACKGROUND/AIM: Spongiform venous malformations (sVMs) get symptomatic in >90% of cases during a person's lifetime. Misdiagnosis is still common and treatment often incomplete, making this disease a lifelong issue for patients with a relevant impact on their quality of life. PATIENTS AND METHODS: Medical records and imaging studies of patients with VMs from April 2002 to January 2017 were reviewed for confirmation of diagnosis and classification of the VMs. Only sVMs were included. Subjective data were obtained from the survey related to indication, response, and complications. We analyzed the frequency of correct diagnosis and Quality of Life by an SF12-based questionnaire for sVM-related issues in Swiss patients. RESULTS: A total of 80 patients were included in the study. Forty-six (58%) patients were females. Patients were 11.6-77 years old with a median age of 28.1 years. The correct diagnosis according to the ISSVA-classification after having been seen at our Institution was 87%. Thirty-one (39%) patients responded to the survey. Sixteen (51%) were female. Twenty-eight (90%) patients felt that their sVM-related state of health improved within a year. Twelve (39%) patients reported that they could not work as good as normal because of slight to modest impairment by the sVM, while 19 (61%) patients were unimpaired. Mental impairment was found in 8 (26%) patients, while 23 (74%) patients felt no impairment. Eight (26%) patients reported that they were impaired within social contacts due to their sVM. Only 9 (29%) patients reported that venous malformation was diagnosed around birth. Twenty-three (74%) patients received a wrong diagnosis. Patients that were treated, reported close to complete relief of symptoms in 26% (8 patients) while also 26% (8 patients) reported no change of symptoms after therapy. CONCLUSION: Swiss sVM patients also suffer from misdiagnosis and late diagnosis. They are impacted in their daily life by their disease.


Subject(s)
Quality of Life , Vascular Malformations , Adolescent , Adult , Aged , Child , Diagnostic Imaging , Female , Humans , Middle Aged , Surveys and Questionnaires , Switzerland/epidemiology , Vascular Malformations/diagnosis , Young Adult
4.
Ann Vasc Surg ; 68: 451-459, 2020 Oct.
Article in English | MEDLINE | ID: mdl-32278869

ABSTRACT

BACKGROUND: Hemodynamics has been known to play a major role in the development of intimal hyperplasia leading to arteriovenous fistula failure. The goal of our study is to investigate the influence of different angles of side-to-end radiocephalic anastomosis on the hemodynamic parameters that promote intimal dysfunction and therefore intimal hyperplasia. METHODS: Realistic three-dimensional meshes were reconstructed using ultrasound measurements from distal side-to-end radiocephalic fistulas. The velocity at the proximal and distal radial inflows and at specific locations along the anastomosis and cephalic vein was measured through duplex ultrasound performed by a single examiner. A computational parametric study, virtually changing the inner angle of anastomosis, was performed. For this purpose, we used advanced computational models that include suitable tools to capture the pulsatile and turbulent nature of the blood flow found in arteriovenous fistulas. The results were analyzed in terms of velocity fields, wall shear stress distribution, and oscillatory shear index. RESULTS: Results show that the regions with high oscillatory shear index, which are more prone to the development of hyperplasia, are greater and progressively shift toward the anastomosis area and the proximal vein segment with the decrease of the inner angle of anastomosis. These results are specific to distal radiocephalic fistulas because they are subject to proximal and distal radial inflow. CONCLUSIONS: The results of this study show that inner anastomosis angles approaching 60-70° seem to yield the best hemodynamic conditions for maturation and long-term patency of distal radiocephalic fistulas. Inner angles greater than 90°, representing the smooth loop technique, did not show a clear hemodynamic advantage.


Subject(s)
Arteriovenous Shunt, Surgical , Forearm/blood supply , Hemodynamics , Models, Cardiovascular , Patient-Specific Modeling , Radial Artery/surgery , Veins/surgery , Arteriovenous Shunt, Surgical/adverse effects , Blood Flow Velocity , Humans , Hyperplasia , Neointima , Radial Artery/diagnostic imaging , Radial Artery/physiopathology , Stress, Mechanical , Treatment Outcome , Ultrasonography, Doppler, Duplex , Vascular Patency , Veins/diagnostic imaging , Veins/physiopathology
5.
Ann Vasc Surg ; 62: 206-212, 2020 Jan.
Article in English | MEDLINE | ID: mdl-31449938

ABSTRACT

BACKGROUND: We describe the long-term follow-up of patients treated for infrarenal abdominal aortic aneurysms and penetrating ulcers by placement of tubular aortic endografts at our institution from 2010 to present. METHODS: This is a retrospective study using clinical data of patients treated from 2010 to present by placement of either a single aortic tubular endograft or by two overlapping endografts, using the "trombone technique." Aortic dimensions were measured from the preoperative computed tomography scans using three-dimensional reconstruction. The primary outcome was aortic reintervention. Secondary outcomes were aorta-related mortality, endoleaks, and postoperative complications. RESULTS: Twenty-eight patients were identified. Nine patients were treated for saccular aneurysms, and nineteen patients presented with penetrating aortic ulcers. The median follow-up was 31 months (range: 4-99). Twenty patients were treated with a single tubular device, while eight patients were treated using two overlapping devices. Aortic reintervention occurred in four patients (14.3%), all were treated initially with a single device. No aortic mortality occurred during follow-up. No aneurysm ruptures occurred. Four patients died during follow-up of unrelated causes. Endoleaks occurred in ten patients (35%). Five endoleaks were of type I (17.8%), of which three were of distal type (10.7%). Five endoleaks were of type II (17.8%). Shorter distal landing zones than 20 mm were present in two of the cases with a distal type I endoleak (P = 0.0232). Postoperative complications occurred in three (10.7%) patients including one myocardial infarction and two wound complications from a surgical cut down in the groin. CONCLUSIONS: The technique shows an acceptable postoperative complication rate but is characterized by high rate of occurrence of type I endoleaks and aortic reintervention in our series. Endovascular techniques using tubular endografts should be limited to cases with long proximal and distal sealing zones. The trombone technique seems preferable.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Endovascular Procedures/instrumentation , Ulcer/surgery , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/mortality , Blood Vessel Prosthesis Implantation/adverse effects , Blood Vessel Prosthesis Implantation/mortality , Cause of Death , Endoleak/etiology , Endoleak/therapy , Endovascular Procedures/adverse effects , Endovascular Procedures/mortality , Female , Humans , Male , Middle Aged , Prosthesis Design , Reoperation , Retrospective Studies , Risk Factors , Switzerland , Time Factors , Treatment Outcome , Ulcer/diagnostic imaging , Ulcer/mortality
6.
Swiss Med Wkly ; 147: w14412, 2017.
Article in English | MEDLINE | ID: mdl-28322421

ABSTRACT

QUESTIONS UNDER STUDY: This pilot study aimed to assess the feasibility, acceptance and costs of an ultrasound scan screening programme for abdominal aortic aneurysms (AAA) in the elderly male population resident in Canton Ticino, Switzerland. METHODS: The target population were male patients aged 65-80 years who attended the outpatient clinics of the Lugano Regional Hospital in 2013. The patients showing interest were contacted by phone to verify their eligibility and fix the appointment for the ultrasound scan of the abdominal aorta. Patients with recent examinations suitable for AAA detection were excluded. Aneurysm was defined as an abdominal aorta with sagittal and/or axial diameter  30 mm. Patients' characteristics and study results were presented as descriptive statistics. The chi-squared test was used to compare categorical variables with p <0.05 as a statistical significance threshold. RESULTS: 1634 patients received the screening information leaflet and 745 (45.6%) underwent the ultrasound scan. Among the 1091 eligible patients, the acceptance rate was 68.3%. A previously unknown AAA was diagnosed in 31 patients (4.2%, 95% confidence interval 2.8-5.9%). Age and area of residence had a statistically significant impact on patient's acceptance rate (p <0.05). The mean cost per screened patient was CHF 88. CONCLUSIONS: AAA screening of male patients aged 65-80 years is feasible with limited financial and organisational effort. Adherence might be improved by a larger community-based programme and involvement of general practitioners.


Subject(s)
Aortic Aneurysm, Abdominal/diagnosis , Mass Screening/methods , Ultrasonography/methods , Aged , Aged, 80 and over , Aortic Aneurysm, Abdominal/diagnostic imaging , Humans , Male , Pilot Projects , Prospective Studies , Risk Factors , Switzerland , Time Factors
7.
Ann Vasc Surg ; 35: 205.e13-7, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27236095

ABSTRACT

Infective aortitis (IA) and penetrating aortic ulcer (PAU) impending for rupture represent 2 hostile life-threatening conditions. Simultaneous presentations of these rare entities can be considered an exception. The pleomorphic clinical presentation and the multifactorial etiology require a multidisciplinary approach to reach a correct diagnosis and an urgent treatment. We report the case of a 65-year-old patient presented with acute abdominal pain and septic shock secondary to a bacterial aortitis and penetrating ulcer of abdominal aorta. Unfit for surgery due to severe comorbidities, he was treated by means of a tubular endograft and long-term antibiotic therapy. A rapid improvement of clinical conditions was observed during the subsequent hospital stay. Complete regression of aortic involvement was demonstrated after 1 year. In conclusion, for selected patients affected by IA and PAU an endovascular approach associated to long-term antibiotic therapy may be safe and effective.


Subject(s)
Aorta, Abdominal/surgery , Aortitis/microbiology , Blood Vessel Prosthesis Implantation , Endovascular Procedures , Staphylococcal Infections/microbiology , Ulcer/surgery , Abdominal Pain/microbiology , Acute Pain/microbiology , Aged , Anti-Bacterial Agents/administration & dosage , Aorta, Abdominal/diagnostic imaging , Aorta, Abdominal/microbiology , Aortitis/diagnosis , Aortitis/drug therapy , Aortography/methods , Blood Vessel Prosthesis , Blood Vessel Prosthesis Implantation/instrumentation , Computed Tomography Angiography , Endovascular Procedures/instrumentation , Humans , Male , Positron Emission Tomography Computed Tomography , Shock, Septic/microbiology , Staphylococcal Infections/diagnosis , Staphylococcal Infections/drug therapy , Treatment Outcome , Ulcer/diagnostic imaging , Ulcer/microbiology
8.
Rare Tumors ; 6(2): 5225, 2014 May 13.
Article in English | MEDLINE | ID: mdl-25002945

ABSTRACT

We report a case of a 63-years-old woman with a ten years history of increasing abdominal girth with associated abdominal pain. Abdomino-pelvic ultrasound and computed tomography scan revealed a large left ovarian cyst. The patient underwent laparotomy, resection of ovarian cyst and hysterectomy with bilateral ovarian resection. The removed huge mucinous cystadenoma, weighed 27 kg. Her post-operative course was unremarkable.

9.
J Vasc Access ; 15 Suppl 7: S6-9, 2014.
Article in English | MEDLINE | ID: mdl-24817447

ABSTRACT

PURPOSE: The intraoperative quality assessment of the arteriovenous fistula for hemodialysis is an essential process to limit early failure due to technical problems or inadequate vascular quality. This step is not clearly defined in the literature with no recommendations. METHODS: We selected published articles related to the topic of intraoperative quality control of the vascular access for hemodialysis. RESULTS: The intraoperative blood flow measurement greater than 120 ml/min in autologous fistula and less than 320 ml/min in arteriovenous graft was described as predictive factors for early failure. CONCLUSIONS: The blood flow measurement should be performed after the confection of the anastomosis. When blood flow is limited, fistulography is an essential step to assess patency.


Subject(s)
Arteriovenous Shunt, Surgical , Blood Vessel Prosthesis Implantation , Intraoperative Care , Kidney Failure, Chronic/therapy , Renal Dialysis , Arteriovenous Shunt, Surgical/adverse effects , Blood Flow Velocity , Blood Vessel Prosthesis Implantation/adverse effects , Diagnostic Techniques, Cardiovascular , Humans , Kidney Failure, Chronic/diagnosis , Predictive Value of Tests , Regional Blood Flow , Treatment Outcome , Vascular Patency
10.
Int Surg ; 97(2): 129-34, 2012.
Article in English | MEDLINE | ID: mdl-23102078

ABSTRACT

Postoperative delirium, morbidity, and mortality in our elderly patients with secondary perionitis of colorectal origin is described. This is a chart-based retrospective analysis of 63 patients who were operated on at the University Hospital Basel from April 2001 to May 2004. Postoperative delirium occurred in 33%. Overall morbidity was 71.4%. Surgery-related morbidity was 43.4%. Mortality was 14.4%. There was no statistical significance between delirium, morbidity and mortality (P  =  0.279 and P  =  0.364). There was no statistically significant correlation between the analyzed scores (American Society of Anesthesiologists classification, Mannheimer Peritonitis Index, Acute Physiology and Chronic Health Evaluation score II, physiological and operative surgical severity and enumeration of morbidity and mortality score' or short 'cr-POSSUM') and postoperative delirium, morbidity or mortality. Postoperative delirium occurred in one-third of the patients, who seem to have a trend to higher morbidity. Even if the different scores already had proven to be predictive in terms of morbidity and mortality, they do not help the risk stratification of postoperative delirium, morbidity, or mortality in our collective population.


Subject(s)
Colon/surgery , Delirium/etiology , Peritonitis/surgery , Postoperative Complications/surgery , Rectum/surgery , APACHE , Age Factors , Aged , Aged, 80 and over , Decision Support Techniques , Delirium/diagnosis , Delirium/epidemiology , Emergencies , Female , Humans , Male , Peritonitis/etiology , Peritonitis/mortality , Postoperative Complications/epidemiology , Retrospective Studies , Risk Factors , Severity of Illness Index , Treatment Outcome
11.
J Vasc Surg ; 54(3): 840-3, 2011 Sep.
Article in English | MEDLINE | ID: mdl-21477964

ABSTRACT

We report the first documented case of distal thromboembolism originating from an abdominal aortic aneurysm (AAA) after a blunt trauma. A 72-year-old man with a known 6.2 cm AAA was brought to our emergency department with signs of bilateral acute limb ischemia developing immediately after an accidental fall. The occlusion was confirmed at computed tomographic angiography, and the aneurysm showed a fragmentated/ulcerated mural thrombus, morphologically different as compared to the previous computed tomography (CT). A thromboembolectomy was performed and, after treatment of the ischemic complications, the aneurysm was repaired by open surgery. Embolization from aneurysms in the setting of a trauma is a challenge for the vascular surgeon, also because of its rare occurrence. We describe the management and discuss the operative strategy we opted for in this patient.


Subject(s)
Accidental Falls , Aortic Aneurysm, Abdominal/complications , Ischemia/etiology , Lower Extremity/blood supply , Thromboembolism/etiology , Aged , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/surgery , Aortography/methods , Embolectomy , Humans , Ischemia/diagnostic imaging , Ischemia/surgery , Male , Thrombectomy , Thromboembolism/diagnostic imaging , Thromboembolism/surgery , Tomography, X-Ray Computed , Treatment Outcome
13.
Langenbecks Arch Surg ; 395(1): 95-7, 2010 Jan.
Article in English | MEDLINE | ID: mdl-19526247

ABSTRACT

BACKGROUND: Bilioenteric fistulas are rare complications of cholecystolithiasis that are associated with high morbidity and mortality and mainly appear in elderly patients. CASE PRESENTATION: This is the report of a patient suffering from cholecystoduodenal fistula with additional cholecystocolonic fistula. DISCUSSION: This cholecystocolonic fistula provoked a short bowel syndrome with symptomatic diarrhea and prevented an upper gastrointestinal ileus caused by the large perforated gallstone into the duodenum. This interesting constellation has not been described in literature yet.


Subject(s)
Cholecystectomy/methods , Cholecystolithiasis/surgery , Intestinal Fistula/surgery , Intestinal Obstruction/prevention & control , Abdominal Pain/diagnosis , Abdominal Pain/etiology , Aged, 80 and over , Cholecystolithiasis/complications , Cholecystolithiasis/diagnostic imaging , Female , Follow-Up Studies , Gallstones/complications , Gallstones/diagnostic imaging , Gallstones/surgery , Humans , Intestinal Fistula/diagnostic imaging , Intestinal Fistula/etiology , Intestinal Obstruction/diagnostic imaging , Intraoperative Care/methods , Laparotomy/methods , Risk Assessment , Tomography, X-Ray Computed , Treatment Outcome
14.
World J Surg ; 32(12): 2599-606, 2008 Dec.
Article in English | MEDLINE | ID: mdl-18836763

ABSTRACT

BACKGROUND: Whereas specimen radiography (SR) is an established strategy for intraoperative resection margin analysis during breast-conserving surgery for nonpalpable lesions, the use of frozen section analysis (FSA) is still a matter of debate. METHODS: A retrospective review was conducted of 115 consecutive operations in which the two objectives sought were the excision of nonpalpable malignant lesions and breast conservation. Breast surgery was performed in the Gynecology and the Surgery Departments at the Basel University Hospital Breast Center. Whereas one department preferably uses SR for intraoperative margin assessments of lesions involving ductal carcinoma in situ (DCIS) or atypical ductal hyperplasia, the other uses FSA to increase the rate of complete removal of these lesions with a single procedure. The respective accuracy and therapeutic impact of these two techniques are compared here. RESULTS: Intraoperative resection margin assessments were performed with FSA in 80 and SR in 35 of a total of 115 operations performed on 111 patients with pTis, pT1, or pT2 nonpalpable breast cancer. FSA diagnostic accuracy, sensitivity, and specificity were 83.8%, 80.0%, and 87.5%, respectively, compared to 60%, 60%, and 60%, respectively, for SR. FSA tended to have a stronger therapeutic impact than SR in terms of the number of patients in whom initially positive margins were rendered margin-negative thanks to intraoperative analysis and immediate reexcision or mastectomy (27.5% vs. 14.3%; p = 0.124). More importantly, significantly fewer secondary reexcisions were performed in the FSA series than in the SR series (12.5% vs. 37.1%; p = 0.002). Finally, the intraoperative detection of invasive cancer with FSA led to a significantly lower number of secondary procedures for axillary lymph node staging (5% vs. 25.7%; p = 0.001). CONCLUSIONS: The present results suggest that FSA may be more accurate than SR for analyzing intraoperative resection margins during breast-conserving surgery for nonpalpable lesions.


Subject(s)
Breast Neoplasms/diagnostic imaging , Breast Neoplasms/pathology , Carcinoma/diagnostic imaging , Carcinoma/pathology , Frozen Sections , Mammography , Adult , Aged , Aged, 80 and over , Breast Neoplasms/surgery , Carcinoma/surgery , Cohort Studies , Female , Humans , Mastectomy, Segmental , Middle Aged , Neoplasm Staging , Predictive Value of Tests , Reproducibility of Results , Retrospective Studies
SELECTION OF CITATIONS
SEARCH DETAIL
...