Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Sci Rep ; 11(1): 24418, 2021 Dec 24.
Article in English | MEDLINE | ID: mdl-34952912

ABSTRACT

At the Center for Advanced Laser Applications (CALA), Garching, Germany, the LION (Laser-driven ION Acceleration) experiment is being commissioned, aiming at the production of laser-driven bunches of protons and light ions with multi-MeV energies and repetition frequency up to 1 Hz. A Geant4 Monte Carlo-based study of the secondary neutron and photon fields expected during LION's different commissioning phases is presented. Goal of this study is the characterization of the secondary radiation environment present inside and outside the LION cave. Three different primary proton spectra, taken from experimental results reported in the literature and representative of three different future stages of the LION's commissioning path are used. Together with protons, also electrons are emitted through laser-target interaction and are also responsible for the production of secondary radiation. For the electron component of the three source terms, a simplified exponential model is used. Moreover, in order to reduce the simulation complexity, a two-components simplified geometrical model of proton and electron sources is proposed. It has been found that the radiation environment inside the experimental cave is either dominated by photons or neutrons depending on the position in the room and the source term used. The higher the intensity of the source, the higher the neutron contribution to the total dose for all scored positions. Maximum neutron and photon ambient dose equivalent values normalized to 109 simulated incident primaries were calculated at the exit of the vacuum chamber, where values of about 85 nSv (109 primaries)-1 and 1.0 µSv (109 primaries)-1 were found.

2.
Nat Commun ; 11(1): 6174, 2020 12 02.
Article in English | MEDLINE | ID: mdl-33268784

ABSTRACT

Radiographic imaging with x-rays and protons is an omnipresent tool in basic research and applications in industry, material science and medical diagnostics. The information contained in both modalities can often be valuable in principle, but difficult to access simultaneously. Laser-driven solid-density plasma-sources deliver both kinds of radiation, but mostly single modalities have been explored for applications. Their potential for bi-modal radiographic imaging has never been fully realized, due to problems in generating appropriate sources and separating image modalities. Here, we report on the generation of proton and x-ray micro-sources in laser-plasma interactions of the focused Texas Petawatt laser with solid-density, micrometer-sized tungsten needles. We apply them for bi-modal radiographic imaging of biological and technological objects in a single laser shot. Thereby, advantages of laser-driven sources could be enriched beyond their small footprint by embracing their additional unique properties, including the spectral bandwidth, small source size and multi-mode emission.


Subject(s)
Gryllidae/ultrastructure , Multimodal Imaging/methods , Radiography/methods , Animals , Lasers , Multimodal Imaging/instrumentation , Protons , Radiography/instrumentation , X-Rays
3.
Rev Sci Instrum ; 89(1): 013301, 2018 Jan.
Article in English | MEDLINE | ID: mdl-29390656

ABSTRACT

Laser-based ion acceleration is driven by electrical fields emerging when target electrons absorb laser energy and consecutively leave the target material. A direct correlation between these electrons and the accelerated ions is thus to be expected and predicted by theoretical models. We report on a modified wide-angle spectrometer, allowing the simultaneous characterization of angularly resolved energy distributions of both ions and electrons. Equipped with online pixel detectors, the RadEye1 detectors, the investigation of this correlation gets attainable on a single shot basis. In addition to first insights, we present a novel approach for reliably extracting the primary electron energy distribution from the interfering secondary radiation background. This proves vitally important for quantitative extraction of average electron energies (temperatures) and emitted total charge.

4.
Phys Med Biol ; 61(2): 958-73, 2016 Jan 21.
Article in English | MEDLINE | ID: mdl-26738626

ABSTRACT

Due to the low-dose envelope of scanned proton beams, the dose output depends on the size of the irradiated field or volume. While this field size dependence has already been extensively investigated by measurements and Monte Carlo (MC) simulations for single pencil beams or monoenergetic fields, reports on the relevance of this effect for analytical dose calculation models are limited. Previous studies on this topic only exist for specific beamline designs. However, the amount of large-angle scattered primary and long-range secondary particles and thus the relevance of the low-dose envelope can considerably be influenced by the particular design of the treatment nozzle. In this work, we therefore addressed the field size dependence of the dose output at the commercially available ProBeam(®) beamline, which is being built in several facilities worldwide. We compared treatment planning dose calculations with ionization chamber (IC) measurements and MC simulations, using an experimentally validated FLUKA MC model of the scanning beamline. To this aim, monoenergetic square fields of three energies, as well as spherical target volumes were studied, including the investigation on the influence of the lateral spot spacing on the field size dependence. For the spherical target volumes, MC as well as analytical dose calculation were found in excellent agreement with the measurements in the center of the spread-out Bragg peak. In the plateau region, the treatment planning system (TPS) tended to overestimate the dose compared to MC calculations and IC measurements by up to almost 5% for the smallest investigated sphere and for small monoenergetic square fields. Narrower spot spacing slightly enhanced the field size dependence of the dose output. The deviations in the plateau dose were found to go in the clinically safe direction, i.e. the actual deposited dose outside the target was found to be lower than predicted by the TPS. Thus, the moderate overestimation of dose to normal tissue by the TPS is likely to result in no severe consequences in clinical cases, even for the most critical cases of small target volumes.


Subject(s)
Algorithms , Proton Therapy/methods , Radiotherapy Planning, Computer-Assisted/methods , Radiometry/methods , Radiotherapy Dosage
SELECTION OF CITATIONS
SEARCH DETAIL
...