Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
1.
Arch Cardiol Mex ; 2024 Feb 15.
Article in Spanish | MEDLINE | ID: mdl-38359441

ABSTRACT

Chronic thromboembolic pulmonary hypertension (CTEPH) is a subtype of pulmonary hypertension characterized by the obstruction of pulmonary arteries secondary to chronic thromboembolism. Pulmonary thromboendarterectomy surgery (PTE) is the main treatment for patients with CTEPH, as it removes the chronic thrombi from the pulmonary arteries. Pulmonary reperfusion syndrome is a common complication of the surgery, which involves the development of pulmonary edema in the area where blood perfusion improves after the surgery. The incidence of this syndrome varies from 8 to 91% depending on the criteria used for diagnosis, and it is one of the most serious complications of pulmonary thromboendarterectomy. In such cases, circulatory support with extracorporeal membrane oxygenation (ECMO) has become a valuable therapeutic modality. We present the case of a 60-year-old woman with a history of acute pulmonary embolism due to deep vein thrombosis of the right pelvic limb who was diagnosed later with CTEPH who was admitted for scheduled surgical treatment involving bilateral PTE. However, during the immediate postoperative period, she developed cardiogenic shock and refractory hypoxemia secondary to pulmonary reperfusion syndrome following the surgical procedure. As a result, she required veno-venous ECMO circulatory support for 6 days, leading to resolution of the pulmonary condition and clinical improvement.


La hipertensión pulmonar tromboembólica crónica (HPTEC) es un subtipo de hipertensión pulmonar caracterizada por la obstrucción de las arterias pulmonares secundaria a tromboembolias crónicas. La cirugía de tromboendarterectomía pulmonar (TEAP) es el tratamiento principal para los pacientes con HPTEC, elimina los trombos crónicos de las arterias pulmonares. El síndrome de reperfusión pulmonar es una complicación común de la cirugía, se trata del desarrollo de edema pulmonar en el área en la que la perfusión sanguínea mejora después de la cirugía. La incidencia del síndrome varía del 8 al 91% según los criterios utilizados para diagnosticarlo y es una de las complicaciones más graves de la tromboendarterectomía pulmonar. En tales casos, el soporte circulatorio con oxigenación por membrana extracorpórea (ECMO) se ha convertido en una valiosa modalidad terapéutica. Presentamos el caso de una paciente de 60 años de edad con antecedente de tromboembolia pulmonar aguda secundaria a trombosis venosa profunda de miembro pélvico derecho a quien durante el seguimiento se realizó el diagnóstico de HPTEC e ingresó de manera programada para tratamiento quirúrgico con realización de TEAP bilateral, sin embargo durante el posquirúrgico inmediato presentó choque cardiogénico e hipoxemia refractaria secundarios a síndrome de reperfusión pulmonar, por lo cual requirió soporte circulatorio con ECMO venovenosa durante seis días, con resolución del cuadro pulmonar y mejoría clínica.

2.
Echocardiography ; 40(3): 299-302, 2023 03.
Article in English | MEDLINE | ID: mdl-36799210

ABSTRACT

Using an ultrasound-enhancing agent (UEA) has several indications, especially in diagnosing left ventricular thrombus. Herein, we present three cases of patients who were candidates for venous-arterial extracorporeal membrane oxygenation, among whom thrombus was ruled out via contrast echocardiography. The use of a UEA in these patients was a novel approach.


Subject(s)
Extracorporeal Membrane Oxygenation , Thrombosis , Humans , Extracorporeal Membrane Oxygenation/adverse effects , Extracorporeal Membrane Oxygenation/methods , Echocardiography , Thrombosis/etiology
3.
Arch. cardiol. Méx ; 92(4): 469-475, Oct.-Dec. 2022. tab
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1429681

ABSTRACT

Resumen Introducción: La saturación de oxígeno y el lactato son marcadores de hipoxia tisular, se obtienen de muestra venosa mezclada en arteria pulmonar o venosa central. Se desconoce el comportamiento simultáneo de estos parámetros en el postoperatorio de cirugía cardiaca. Objetivo: Caracterizar la saturación de oxígeno y lactato del circuito venoso-arterial del paciente postoperado de cirugía cardiaca. Métodos: Diseño transversal analítico. En pacientes consecutivos postoperados de cirugía cardiaca se obtuvieron lactato sérico y saturación de oxígeno del circuito venoso-arterial. Las variables se informaron con mediana (percentiles 25 y 75). Se analizaron con ANOVA de Kruskal-Wallis y ajuste respectivo, correlación de Spearman, el estadístico descriptivo de Bland-Altman y coeficiente de correlación intraclase (intervalo de confianza al 95%). Una p < 0.05 se consideró significativa. Resultados: Se estudiaron 244 muestras sanguíneas de 61 pacientes. Mujeres 30 (49%). Saturación de oxígeno y lactato fueron: arterial 98 (95.3, 99.4)% y 1.7 (1,1, 2.1); venosa periférica 85 (75.4, 94)% y 1.9 (1.35, 2.3); venosa central 68.8 (58.74, 70.2)% y 1.8 (1.3, 2.3); venosa central mezclada 66.8 (61.2, 73.1)% y 1.8 (1.3, 2.2), p < 0.05. El mejor coeficiente de correlación intraclase para la saturación de oxígeno fue de vena central a vena central mezclada: 0.856 (0.760, 0.914); del lactato: 0.954 (0.923, 0.972). Conclusiones: La saturación de oxígeno difiere en el circuito venoso-arterial a diferencia del lactato, donde son similares. Los mejores valores del coeficiente de correlación intraclase para el lactato y la saturación de oxígeno fueron los obtenidos en vena central y vena central mezclada.


Abstract Introduction: Oxygen saturation and lactate are markers of tissue hypoxia; they are obtained from central venous and mixed venous sample of the pulmonary artery. The simultaneous behavior of these parameters in the postoperative period of cardiac surgery is unknown. Objective: To characterize the lactate and oxygen saturation of the venous-arterial circuit of the postoperative patient from cardiac surgery. Methods: Design: Analytical cross-sectional. In consecutive patients after cardiac surgery, serum lactate and oxygen saturation of the venous-arterial circuit were obtained. The variables were reported with median (25.75 percentiles). They were analyzed with Kruskal-Wallis ANOVA and respective adjustment, Spearman correlation, the descriptive Bland-Altman statistic and intraclass correlation coefficient (95% confidence interval). A p < 0.05 was considered significant. Results: 244 blood samples from 61 patients were studied. Women 30 (49%). (Oxygen saturation) [lactate] were: arterial 98 (95.3, 99.4%) and 1.7 (1.1, 2.1); peripheral venous 85 (75.4, 94%) and [1.9 (1.35, 2.3)]; central venous 68.8 (58.74, 70.2%) and 1.8 (1.3, 2.3); mixed central venous 66.8 (61.2, 73.1%) and 1.8 (1.3, 2.2), p < 0.05. The best intraclass correlation coefficient for oxygen saturation were from central vein to mixed central vein 0.856 (0.760,0.914); and lactate: 0.954 (0.923, 0.972). Conclusions: The oxygen saturation differs in the venous-arterial circuit unlike lactate where they are similar. The best values of the intraclass correlation coefficient for lactate and oxygen saturation were those obtained in central vein and mixed central vein.

4.
Arch Cardiol Mex ; 92(4): 469-475, 2022.
Article in English | MEDLINE | ID: mdl-36413688

ABSTRACT

INTRODUCTION: Oxygen saturation and lactate are markers of tissue hypoxia; they are obtained from central venous and mixed venous sample of the pulmonary artery. The simultaneous behavior of these parameters in the postoperative period of cardiac surgery is unknown. OBJECTIVE: To characterize the lactate and oxygen saturation of the venous-arterial circuit of the postoperative patient from cardiac surgery. METHODS: Design: Analytical cross-sectional. In consecutive patients after cardiac surgery, serum lactate and oxygen saturation of the venous-arterial circuit were obtained. The variables were reported with median (25.75 percentiles). They were analyzed with Kruskal-Wallis ANOVA and respective adjustment, Spearman correlation, the descriptive Bland-Altman statistic and intraclass correlation coefficient (95% confidence interval). A p < 0.05 was considered significant. RESULTS: 244 blood samples from 61 patients were studied. Women 30 (49%). (Oxygen saturation) [lactate] were: arterial 98 (95.3, 99.4%) and 1.7 (1.1, 2.1); peripheral venous 85 (75.4, 94%) and [1.9 (1.35, 2.3)]; central venous 68.8 (58.74, 70.2%) and 1.8 (1.3, 2.3); mixed central venous 66.8 (61.2, 73.1%) and 1.8 (1.3, 2.2), p < 0.05. The best intraclass correlation coefficient for oxygen saturation were from central vein to mixed central vein 0.856 (0.760,0.914); and lactate: 0.954 (0.923, 0.972). CONCLUSIONS: The oxygen saturation differs in the venous-arterial circuit unlike lactate where they are similar. The best values of the intraclass correlation coefficient for lactate and oxygen saturation were those obtained in central vein and mixed central vein.


INTRODUCCIÓN: La saturación de oxígeno y el lactato son marcadores de hipoxia tisular, se obtienen de muestra venosa mezclada en arteria pulmonar o venosa central. Se desconoce el comportamiento simultáneo de estos parámetros en el postoperatorio de cirugía cardiaca. OBJETIVO: Caracterizar la saturación de oxígeno y lactato del circuito venoso-arterial del paciente postoperado de cirugía cardiaca. MÉTODOS: Diseño transversal analítico. En pacientes consecutivos postoperados de cirugía cardiaca se obtuvieron lactato sérico y saturación de oxígeno del circuito venoso-arterial. Las variables se informaron con mediana (percentiles 25 y 75). Se analizaron con ANOVA de Kruskal-Wallis y ajuste respectivo, correlación de Spearman, el estadístico descriptivo de Bland-Altman y coeficiente de correlación intraclase (intervalo de confianza al 95%). Una p < 0.05 se consideró significativa. RESULTADOS: Se estudiaron 244 muestras sanguíneas de 61 pacientes. Mujeres 30 (49%). Saturación de oxígeno y lactato fueron: arterial 98 (95.3, 99.4)% y 1.7 (1,1, 2.1); venosa periférica 85 (75.4, 94)% y 1.9 (1.35, 2.3); venosa central 68.8 (58.74, 70.2)% y 1.8 (1.3, 2.3); venosa central mezclada 66.8 (61.2, 73.1)% y 1.8 (1.3, 2.2), p < 0.05. El mejor coeficiente de correlación intraclase para la saturación de oxígeno fue de vena central a vena central mezclada: 0.856 (0.760, 0.914); del lactato: 0.954 (0.923, 0.972). CONCLUSIONES: La saturación de oxígeno difiere en el circuito venoso-arterial a diferencia del lactato, donde son similares. Los mejores valores del coeficiente de correlación intraclase para el lactato y la saturación de oxígeno fueron los obtenidos en vena central y vena central mezclada.


Subject(s)
Cardiac Surgical Procedures , Oxygen Saturation , Humans , Female , Cross-Sectional Studies , Oxygen , Lactic Acid , Postoperative Period
5.
JACC Case Rep ; 4(15): 919-923, 2022 Aug 03.
Article in English | MEDLINE | ID: mdl-35935162

ABSTRACT

The intra-aortic balloon pump continues to be a useful ventricular assist device in cardiac surgery. Complications are estimated to be 7% to 40%, significantly high to catastrophic. We describe an aortic injury associated with the use of the device and an interdisciplinary management for the diagnostic and therapeutic approach. (Level of Difficulty: Intermediate.).

6.
Nat Commun ; 13(1): 520, 2022 01 26.
Article in English | MEDLINE | ID: mdl-35082280

ABSTRACT

Maintaining the patency of indwelling drainage devices is critical in preventing further complications following an intraventricular hemorrhage (IVH) and other chronic disease management. Surgeons often use drainage devices to remove blood and cerebrospinal fluid but these catheters frequently become occluded with hematoma. Using an implantable magnetic microactuator, we created a self-clearing catheter that can generate large enough forces to break down obstructive blood clots by applying time-varying magnetic fields. In a blood-circulating model, our self-clearing catheters demonstrated a > 7x longer functionality than traditional catheters (211 vs. 27 min) and maintained a low pressure for longer periods (239 vs. 79 min). Using a porcine IVH model, the self-clearing catheters showed a greater survival rate than control catheters (86% vs. 0%) over the course of 6 weeks. The treated animals also had significantly smaller ventricle sizes 1 week after implantation compared to the control animals with traditional catheters. Our results suggest that these magnetic microactuator-embedded smart catheters can expedite the removal of blood from the ventricles and potentially improve the outcomes of critical patients suffering from often deadly IVH.


Subject(s)
Catheters , Drainage/methods , Hemorrhagic Stroke , Thrombosis , Animals , Biomedical Engineering , Cerebral Hemorrhage/diagnostic imaging , Cerebral Hemorrhage/pathology , Cerebral Ventricles/diagnostic imaging , Cerebral Ventricles/pathology , Disease Models, Animal , Drainage/instrumentation , Humans , Male , Swine , Thrombosis/therapy , Treatment Outcome
7.
Adv Funct Mater ; 31(1)2021 Jan 04.
Article in English | MEDLINE | ID: mdl-34764824

ABSTRACT

Accurately replicating and analyzing cellular responses to mechanical cues is vital for exploring metastatic disease progression. However, many of the existing in vitro platforms for applying mechanical stimulation seed cells on synthetic substrates. To better recapitulate physiological conditions, a novel actuating platform is developed with the ability to apply tensile strain on cells at various amplitudes and frequencies in a high-throughput multi-well culture plate using a physiologically-relevant substrate. Suspending fibrillar fibronectin across the body of the magnetic actuator provides a matrix representative of early metastasis for 3D cell culture that is not reliant on a synthetic substrate. This platform enables the culturing and analysis of various cell types in an environment that mimics the dynamic stretching of lung tissue during normal respiration. Metabolic activity, YAP activation, and morphology of breast cancer cells are analyzed within one week of cyclic stretching or static culture. Further, matrix degradation is significantly reduced in breast cancer cell lines with metastatic potential after actuation. These new findings demonstrate a clear suppressive cellular response due to cyclic stretching that has implications for a mechanical role in the dormancy and reactivation of disseminated breast cancer cells to macrometastases.

8.
Cancers (Basel) ; 13(17)2021 Sep 03.
Article in English | MEDLINE | ID: mdl-34503250

ABSTRACT

Worldwide, there are currently around 18.1 million new cancer cases and 9.6 million cancer deaths yearly. Although cancer diagnosis and treatment has improved greatly in the past several decades, a complete understanding of the complex interactions between cancer cells and the tumor microenvironment during primary tumor growth and metastatic expansion is still lacking. Several aspects of the metastatic cascade require in vitro investigation. This is because in vitro work allows for a reduced number of variables and an ability to gather real-time data of cell responses to precise stimuli, decoupling the complex environment surrounding in vivo experimentation. Breakthroughs in our understanding of cancer biology and mechanics through in vitro assays can lead to better-designed ex vivo precision medicine platforms and clinical therapeutics. Multiple techniques have been developed to imitate cancer cells in their primary or metastatic environments, such as spheroids in suspension, microfluidic systems, 3D bioprinting, and hydrogel embedding. Recently, magnetic-based in vitro platforms have been developed to improve the reproducibility of the cell geometries created, precisely move magnetized cell aggregates or fabricated scaffolding, and incorporate static or dynamic loading into the cell or its culture environment. Here, we will review the latest magnetic techniques utilized in these in vitro environments to improve our understanding of cancer cell interactions throughout the various stages of the metastatic cascade.

9.
World Neurosurg ; 155: e294-e300, 2021 11.
Article in English | MEDLINE | ID: mdl-34418611

ABSTRACT

OBJECTIVE: Occlusion of ventriculoperitoneal shunts placed after intraventricular hemorrhage occurs frequently. The objective of this study was to develop a hemorrhagic hydrocephalus model to assess the ability of an oscillating microactuator within the ventricular catheter (VC) to prevent shunt obstruction. METHODS: An in vitro hydrocephalus model with extreme risk of shunt obstruction was created. Phosphate-buffered saline, blood, and thrombin were driven through ventriculoperitoneal shunts for 8 hours. Five VCs were fitted with a microactuator and compared with 5 control VCs. The microactuator was actuated by an external magnetic field for 30 minutes. Pressure within the imitation lateral ventricle was measured. RESULTS: In the 5 control shunts, 6 obstructions developed (3 VC, 3 valve-distal catheter) compared with 1 obstruction (VC) in the 5 microactuator shunts. In the control and microactuator groups, the median volume exiting the shunts in 8 hours was 30 mL versus 256 mL. Median time to reach an intraventricular pressure of 40 mm Hg (13.8 minutes vs. >8 hours), median total time >40 mm Hg (6.2 hours vs. 0.0 hours), and median maximum pressure (192 mm Hg vs. 36 mm Hg) were significantly improved in the microactuator group (P < 0.01). CONCLUSIONS: In addition to protecting the VC, the microactuator appeared to prevent hematoma obstructing the valve or distal catheter, resulting in a much longer duration of low intraventricular pressures. A microactuator activated by placing the patient's head in an external magnetic field could reduce shunt obstructions in hemorrhagic hydrocephalus.


Subject(s)
Catheter Obstruction , Cerebral Hemorrhage/surgery , Equipment Failure Analysis/instrumentation , Hydrocephalus/surgery , Magnetic Fields , Ventriculoperitoneal Shunt/instrumentation , Animals , Catheter Obstruction/adverse effects , Cerebral Hemorrhage/complications , Equipment Failure Analysis/methods , Hydrocephalus/etiology , Models, Biological , Pilot Projects , Swine , Ventriculoperitoneal Shunt/adverse effects
10.
Arch. cardiol. Méx ; 91(1): 100-104, ene.-mar. 2021. graf
Article in Spanish | LILACS | ID: biblio-1152866

ABSTRACT

Resumen La cardiomiopatía de Takotsubo es una entidad caracterizada por disfunción ventricular aguda y transitoria, la cual está generalmente relacionada a un evento desencadenante (estrés emocional o físico) y que, por lo general, se presenta con disfunción sistólica regional del ventrículo izquierdo, aunque hasta en un 30% puede ser biventricular. Según su severidad, en algunos casos puede condicionar choque cardiogénico refractario a manejo con inotrópicos y vasopresores, por lo que para estos casos deben considerarse los dispositivos de asistencia circulatoria. Presentamos el caso de una paciente joven a quien se realizó cambio valvular pulmonar con prótesis biológica, la cual siete semanas posteriores a la cirugía acudió al servicio de urgencias con derrame pericárdico y fisiología de tamponade secundario a síndrome pospericardiotomía. Por tal motivo se le practicó ventana pericárdica, sin embargo durante el transquirúrgico presentó cardiomiopatía de Takotsubo biventricular que le condicionó choque cardiogénico con insuficiencia mitral y tricúspidea severas y refractariedad a tratamiento médico, así como a balón intraaórtico de contrapulsación (BIAC), por lo cual requirió soporte circulatorio con ECMO venoarterial durante 5 días.


Abstract Takotsubo cardiomyopathy is an entity characterized by acute and transient ventricular dysfunction, which is usually related to a triggering event (emotional or physical stress), and usually presents with regional systolic dysfunction of the left ventricle, however up to 30% may be biventricular. Depending on its severity in some cases the disease can condition refractory cardiogenic shock to management with inotropics and vasopressors, so for these cases circulatory assistance devices should be considered. We present the case of a young patient who had pulmonary valve change with biological prosthesis, which seven weeks after surgery went to the emergency department with pericardial effusion and tamponade physiology secondary to postpericardiotomy syndrome. For this reason pericardial window was practiced, however during the procedure she presented biventricular Takotsubo cardiomyopathy which conditioned cardiogenic shock with severe mitral and tricuspid regurgitation, and refractivity to medical treatment as well as intraaortic balloon pump, requiring circulatory support with venoarterial ECMO for 5 days.


Subject(s)
Humans , Female , Adult , Extracorporeal Membrane Oxygenation , Takotsubo Cardiomyopathy/therapy
11.
J Cardiol Cases ; 24(1): 45-48, 2021 Jul.
Article in English | MEDLINE | ID: mdl-33520022

ABSTRACT

Severe forms of COVID-19 infection are associated with the need for invasive mechanical ventilation and thromboembolic complications; those can affect the cardiac function especially the right ventricle performance. Critical care echocardiography has rapidly evolved as the election technique in the evaluation of the critically ill patients. This technique has the advantage that it can be done at patient´s bedside and helps to provide the appropriate treatment and to monitoring maneuver's response. We present 4 patients with a confirmed COVID-19 infection who presented with sudden hemodynamic and / or respiratory deterioration, in which transthoracic echocardiogram showed acute right ventricular failure as the trigger for the event and helped to guide an early therapeutic intervention. .

12.
Arch Cardiol Mex ; 91(1): 100-104, 2020 08 05.
Article in Spanish | MEDLINE | ID: mdl-33008148

ABSTRACT

La cardiomiopatía de Takotsubo es una entidad caracterizada por disfunción ventricular aguda y transitoria, la cual está generalmente relacionada a un evento desencadenante (estrés emocional o físico) y que, por lo general, se presenta con disfunción sistólica regional del ventrículo izquierdo, aunque hasta en un 30% puede ser biventricular. Según su severidad, en algunos casos puede condicionar choque cardiogénico refractario a manejo con inotrópicos y vasopresores, por lo que para estos casos deben considerarse los dispositivos de asistencia circulatoria. Presentamos el caso de una paciente joven a quien se realizó cambio valvular pulmonar con prótesis biológica, la cual siete semanas posteriores a la cirugía acudió al servicio de urgencias con derrame pericárdico y fisiología de tamponade secundario a síndrome pospericardiotomía. Por tal motivo se le practicó ventana pericárdica, sin embargo durante el transquirúrgico presentó cardiomiopatía de Takotsubo biventricular que le condicionó choque cardiogénico con insuficiencia mitral y tricúspidea severas y refractariedad a tratamiento médico, así como a balón intraaórtico de contrapulsación (BIAC), por lo cual requirió soporte circulatorio con ECMO venoarterial durante 5 días.


Subject(s)
Extracorporeal Membrane Oxygenation , Takotsubo Cardiomyopathy/therapy , Adult , Female , Humans
13.
Arch Cardiol Mex ; 90(2): 116-123, 2020.
Article in English | MEDLINE | ID: mdl-32897248

ABSTRACT

Background: Echocardiographic cardiac parameters in the prone position are usually obtained with an esophageal probe. The feasibility of obtaining them by means of a transthoracic approach is unknown. Objective: Estimating the feasibility to obtain parameters of the right ventricle by transthoracic echocardiography in prone position on the subject. Methods: Pilot design of consecutive case series without cardiopulmonary disease. Demographic, vital signs and echocardiographic variables were defined in the ventral initial, prone and ventral final decubitus positions. The data are shown with averages and standard deviations, and frequencies and percentages according to the variable. The differences between the positions were calculated with ANOVA of repeated samples and adjustment of Bonferroni test. Intra-subject variability was obtained by the Bland-Altman procedure and its 95% confidence interval. Results: We studied 50 subjects, 44 (88%) males, age 30 ± 6 years and body mass index 25.65 ± 2.71 kg/m2. Tricuspid annular plane systolic excursion (TAPSE) and S'-wave were measured 100% of the time. The vital signs and echocardiographic variables according to the position had differences in: heart rate (74 ± 9 vs. 77 ± 9 vs. 75 ± 8 beats/min), partial oxygen saturation (94.40 ± 1.70 vs. 96.64 ± 1.79 vs. 95.32 ± 1.36%) and mean systemic blood pressure (65.33 ± 5.38 vs. 67.69 ± 6.31 vs. 65.29 ± 5.62 mmHg); TAPSE (19.74 ± 3.24 vs. 21.60 ± 2.97 vs. 19.44 ± 2.84 mm), mean difference (bias) 0 (2, -2.0) and S'-wave (13.52 ± 1.87 vs. 15.02 ± 2.09 vs. 13.46 ± 1.55 cm/s), mean difference (bias) -0.46 (1.21, -2.14) respectively. Conclusions: Obtaining right ventricle parameters by transthoracic ecocardiopraphy is feasible in the prone position.


Introducción: Los parámetros cardiacos ecocardiográficos en posición de decúbito prono usualmente se obtienen con sonda esofágica. Se desconoce la factibilidad de obtenerlos mediante aproximación transtorácica. Objetivo: Estimar la factibilidad para obtener parámetros del ventrículo derecho mediante ecocardiografía transtorácica en el sujeto en posición de decúbito prono. Métodos: Diseño piloto de serie de casos consecutivos sin enfermedad cardiopulmonar. Se acotaron variables demográficas, signos vitales y ecocardiográficas en posición decúbito ventral inicial, prono y ventral final. Los datos se muestran con promedios y desviaciones estándar, y frecuencias y porcentajes de acuerdo con la variable. La diferencia entre las posiciones se calculó con ANOVA de muestras repetidas y ajuste de Bonferroni. Se obtuvo la variabilidad intrasujetos mediante el procedimiento de Bland-Altman y su intervalo de confianza al 95%. Resultados: Se estudiaron 50 sujetos, 44 (88%) masculinos, edad 30 ± 6 años e índice de masa corporal 25.65 ± 2.71 kg/m2. El TAPSE (excursión sistólica del plano del anillo tricuspídeo) y la onda S' se midieron en el 100% de las veces. Los signos vitales y variables ecocardiográficas de acuerdo con la posición tuvieron diferencias en: frecuencia cardiaca (74 ± 9 vs. 77 ± 9 vs. 75 ± 8 lpm), saturación parcial de oxígeno (94.40 ± 1.70 vs. 96.64 ± 1.79 vs. 95.32 ± 1.36%) y la presión arterial sistémica media (65.33 ± 5.38 vs. 67.69 ± 6.31 vs. 65.29 ± 5.62 mmHg); TAPSE (19.74 ± 3.24 vs. 21.60 ± 2.97 vs. 19.44 vs. 2.84 mm), diferencia media (sesgo) 0 (2, ­2.0) y onda S' (13.52 ± 1.87 vs. 15.02 ± 2.09 vs. 13.46 ± 1.55 cm/s), diferencia media (sesgo) ­0.46 (1.21, ­2.14) respectivamente. Conclusión: En posición de decúbito prono es factible obtener parámetros del ventrículo derecho por ecocardiografía transtorácica.


Subject(s)
Echocardiography/methods , Heart Ventricles/diagnostic imaging , Prone Position , Adult , Feasibility Studies , Female , Humans , Male , Pilot Projects , Young Adult
15.
Echocardiography ; 37(9): 1353-1361, 2020 09.
Article in English | MEDLINE | ID: mdl-32862474

ABSTRACT

BACKGROUND: Coronavirus disease 2019 (COVID-19) is characterized by severe lung involvement and hemodynamic alterations. Critical care ultrasonography is vital because it provides real time information for diagnosis and treatment. Suggested protocols for image acquisition and measurements have not yet been evaluated. METHODS: This cross-sectional study was conducted at two centers from 1 April 2020 to 30 May 2020 in adult patients with confirmed COVID-19 infection admitted to the critical care unit. Cardiac and pulmonary evaluations were performed using the ORACLE protocol, specifically designed for this study, to ensure a structured process of image acquisition and limit staff exposure to the infection. RESULTS: Eighty-two consecutively admitted patients were evaluated. Most of the patients were males, with a median age of 56 years, and the most frequent comorbidities were hypertension and type 2 diabetes, and 25% of the patients had severe acute respiratory distress syndrome. The most frequent ultrasonographic findings were elevated pulmonary artery systolic pressure (69.5%), E/e' ratio > 14 (29.3%), and right ventricular dilatation (28%) and dysfunction (26.8%). A high rate of fluid responsiveness (82.9%) was observed. The median score (19 points) on pulmonary ultrasound did not reveal any variation between the groups. Elevated pulmonary artery systolic pressure was associated with higher in-hospital mortality. CONCLUSION: The ORACLE protocol was a feasible, rapid, and safe bedside tool for hemodynamic and respiratory evaluation of patients with COVID-19. Further studies should be performed on the alteration in pulmonary hemodynamics and right ventricular function and its relationship with outcomes.


Subject(s)
COVID-19/complications , COVID-19/physiopathology , Critical Care/methods , Heart Diseases/diagnostic imaging , Lung Diseases/diagnostic imaging , Ultrasonography/methods , Aged , Clinical Protocols , Cross-Sectional Studies , Feasibility Studies , Female , Heart/diagnostic imaging , Heart/physiopathology , Heart Diseases/etiology , Heart Diseases/physiopathology , Hemodynamics/physiology , Humans , Lung/diagnostic imaging , Lung/physiopathology , Lung Diseases/etiology , Lung Diseases/physiopathology , Male , Middle Aged , Pandemics , Point-of-Care Systems , Ultrasonography/instrumentation
16.
Arch. cardiol. Méx ; 90(2): 116-123, Apr.-Jun. 2020. tab, graf
Article in English | LILACS | ID: biblio-1131019

ABSTRACT

Abstract Background: Echocardiographic cardiac parameters in the prone position are usually obtained with an esophageal probe. The feasibility of obtaining them by means of a transthoracic approach is unknown. Objective: Estimating the feasibility to obtain parameters of the right ventricle by transthoracic echocardiography in prone position on the subject. Methods: Pilot design of consecutive case series without cardiopulmonary disease. Demographic, vital signs and echocardiographic variables were defined in the ventral initial, prone and ventral final decubitus positions. The data are shown with averages and standard deviations, and frequencies and percentages according to the variable. The differences between the positions were calculated with ANOVA of repeated samples and adjustment of Bonferroni test. Intra-subject variability was obtained by the Bland-Altman procedure and its 95% confidence interval. Results: We studied 50 subjects, 44 (88%) males, age 30 ± 6 years and body mass index 25.65 ± 2.71 kg/m2. Tricuspid annular plane systolic excursion (TAPSE) and S'-wave were measured 100% of the time. The vital signs and echocardiographic variables according to the position had differences in: heart rate (74 ± 9 vs. 77 ± 9 vs. 75 ± 8 beats/min), partial oxygen saturation (94.40 ± 1.70 vs. 96.64 ± 1.79 vs. 95.32 ± 1.36%) and mean systemic blood pressure (65.33 ± 5.38 vs. 67.69 ± 6.31 vs. 65.29 ± 5.62 mmHg); TAPSE (19.74 ± 3.24 vs. 21.60 ± 2.97 vs. 19.44 ± 2.84 mm), mean difference (bias) 0 (2, -2.0) and S'-wave (13.52 ± 1.87 vs. 15.02 ± 2.09 vs. 13.46 ± 1.55 cm/s), mean difference (bias) -0.46 (1.21, -2.14) respectively. Conclusions: Obtaining right ventricle parameters by transthoracic ecocardiopraphy is feasible in the prone position.


Resumen Introducción: Los parámetros cardiacos ecocardiográficos en posición de decúbito prono usualmente se obtienen con sonda esofágica. Se desconoce la factibilidad de obtenerlos mediante aproximación transtorácica. Objetivo: Estimar la factibilidad para obtener parámetros del ventrículo derecho mediante ecocardiografía transtorácica en el sujeto en posición de decúbito prono. Métodos: Diseño piloto de serie de casos consecutivos sin enfermedad cardiopulmonar. Se acotaron variables demográficas, signos vitales y ecocardiográficas en posición decúbito ventral inicial, prono y ventral final. Los datos se muestran con promedios y desviaciones estándar, y frecuencias y porcentajes de acuerdo con la variable. La diferencia entre las posiciones se calculó con ANOVA de muestras repetidas y ajuste de Bonferroni. Se obtuvo la variabilidad intrasujetos mediante el procedimiento de Bland-Altman y su intervalo de confianza al 95%. Resultados: Se estudiaron 50 sujetos, 44 (88%) masculinos, edad 30 ± 6 años e índice de masa corporal 25.65 ± 2.71 kg/m2. El TAPSE (excursión sistólica del plano del anillo tricuspídeo) y la onda S' se midieron en el 100% de las veces. Los signos vitales y variables ecocardiográficas de acuerdo con la posición tuvieron diferencias en: frecuencia cardiaca (74 ± 9 vs. 77 ± 9 vs. 75 ± 8 lpm), saturación parcial de oxígeno (94.40 ± 1.70 vs. 96.64 ± 1.79 vs. 95.32 ± 1.36%) y la presión arterial sistémica media (65.33 ± 5.38 vs. 67.69 ± 6.31 vs. 65.29 ± 5.62 mmHg); TAPSE (19.74 ± 3.24 vs. 21.60 ± 2.97 vs. 19.44 vs. 2.84 mm), diferencia media (sesgo) 0 (2, -2.0) y onda S' (13.52 ± 1.87 vs. 15.02 ± 2.09 vs. 13.46 ± 1.55 cm/s), diferencia media (sesgo) -0.46 (1.21, -2.14) respectivamente. Conclusión: En posición de decúbito prono es factible obtener parámetros del ventrículo derecho por ecocardiografía transtorácica.


Subject(s)
Humans , Male , Female , Adult , Young Adult , Echocardiography/methods , Prone Position , Heart Ventricles/diagnostic imaging , Pilot Projects , Feasibility Studies
17.
Arch Cardiol Mex ; 90(2): 130-137, 2020.
Article in English | MEDLINE | ID: mdl-32459216

ABSTRACT

Background: Echocardiographic cardiac parameters in the prone position are usually obtained with an esophageal probe. The feasibility of obtaining them by means of a transthoracic approach is unknown. Objective: Estimating the feasibility to obtain parameters of the right ventricle by transthoracic echocardiography in prone position on the subject. Methods: Pilot design of consecutive case series without cardiopulmonary disease. Demographic, vital signs and echocardiographic variables were defined in the ventral initial, prone and ventral final decubitus positions. The data are shown with averages and standard deviations, and frequencies and percentages according to the variable. The differences between the positions were calculated with ANOVA of repeated samples and adjustment of Bonferroni test. Intra-subject variability was obtained by the Bland-Altman procedure and its 95% confidence interval. Results: We studied 50 subjects, 44 (88%) males, age 30 ± 6 years and body mass index 25.65 ± 2.71 kg/m2. Tricuspid annular plane systolic excursion (TAPSE) and S'-wave were measured 100% of the time. The vital signs and echocardiographic variables according to the position had differences in: heart rate (74 ± 9 vs. 77 ± 9 vs. 75 ± 8 beats/min), partial oxygen saturation (94.40 ± 1.70 vs. 96.64 ± 1.79 vs. 95.32 ± 1.36%) and mean systemic blood pressure (65.33 ± 5.38 vs. 67.69 ± 6.31 vs. 65.29 ± 5.62 mmHg); TAPSE (19.74 ± 3.24 vs. 21.60 ± 2.97 vs. 19.44 ± 2.84 mm), mean difference (bias) 0 (2, -2.0) and S'-wave (13.52 ± 1.87 vs. 15.02 ± 2.09 vs. 13.46 ± 1.55 cm/s), mean difference (bias) -0.46 (1.21, -2.14) respectively. Conclusions: Obtaining right ventricle parameters by transthoracic ecocardiopraphy is feasible in the prone position.


Introducción: Los parámetros cardiacos ecocardiográficos en posición de decúbito prono usualmente se obtienen con sonda esofágica. Se desconoce la factibilidad de obtenerlos mediante aproximación transtorácica. Objetivo: Estimar la factibilidad para obtener parámetros del ventrículo derecho mediante ecocardiografía transtorácica en el sujeto en posición de decúbito prono. Métodos: Diseño piloto de serie de casos consecutivos sin enfermedad cardiopulmonar. Se acotaron variables demográficas, signos vitales y ecocardiográficas en posición decúbito ventral inicial, prono y ventral final. Los datos se muestran con promedios y desviaciones estándar, y frecuencias y porcentajes de acuerdo con la variable. La diferencia entre las posiciones se calculó con ANOVA de muestras repetidas y ajuste de Bonferroni. Se obtuvo la variabilidad intrasujetos mediante el procedimiento de Bland-Altman y su intervalo de confianza al 95%. Resultados: Se estudiaron 50 sujetos, 44 (88%) masculinos, edad 30 ± 6 años e índice de masa corporal 25.65 ± 2.71 kg/m2. El TAPSE (excursión sistólica del plano del anillo tricuspídeo) y la onda S' se midieron en el 100% de las veces. Los signos vitales y variables ecocardiográficas de acuerdo con la posición tuvieron diferencias en: frecuencia cardiaca (74 ± 9 vs. 77 ± 9 vs. 75 ± 8 lpm), saturación parcial de oxígeno (94.40 ± 1.70 vs. 96.64 ± 1.79 vs. 95.32 ± 1.36%) y la presión arterial sistémica media (65.33 ± 5.38 vs. 67.69 ± 6.31 vs. 65.29 ± 5.62 mmHg); TAPSE (19.74 ± 3.24 vs. 21.60 ± 2.97 vs. 19.44 vs. 2.84 mm), diferencia media (sesgo) 0 (2, ­2.0) y onda S' (13.52 ± 1.87 vs. 15.02 ± 2.09 vs. 13.46 ± 1.55 cm/s), diferencia media (sesgo) ­0.46 (1.21, ­2.14) respectivamente. Conclusión: En posición de decúbito prono es factible obtener parámetros del ventrículo derecho por ecocardiografía transtorácica.


Subject(s)
Echocardiography , Heart Ventricles/diagnostic imaging , Prone Position , Adult , Blood Pressure/physiology , Feasibility Studies , Female , Heart Rate/physiology , Humans , Male , Oxygen/metabolism , Patient Positioning , Pilot Projects , Young Adult
18.
Rev. Fac. Med. UNAM ; 63(2): 36-45, mar.-abr. 2020. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1155395

ABSTRACT

Resumen: El ultrasonido pulmonar ha tomado protagonismo en la evaluación de los órganos torácicos y su patología. Es de gran utilidad en la evaluación del paciente hospitalizado o de urgencias para monitoreo de evolución o diagnóstico rápido, así como guía de procedimientos diagnósticos y terapéuticos. Sus múltiples ventajas han desplazado a otros estudios de gabinete, ya que puede evitar el traslado de pacientes, es inocuo, accesible y rápido. En este artículo revisaremos conceptos básicos de ultrasonografía pulmonar y su uso en el diagnóstico en patologías.


Abstract: Lung ultrasound has become increasingly important in the evaluation of the thorax and its pathologies. It has proved to be very useful in the evaluation of hospitalized patients, allowing doctors to evaluate and make quick decisions, as well as providing guidance for diagnostic and therapeutic procedures. Ultrasound has many advantages over other studies since it can avoid transferring patients, and it is harmless, accessible and fast. In this article we will review basic concepts of lung ultrasound and its use in the diagnosis of pathologies.

19.
Arch Cardiol Mex ; 89(4): 348-359, 2019.
Article in English | MEDLINE | ID: mdl-31834314

ABSTRACT

Atrial fibrillation is the most frequent arrhythmia in the postoperative period of cardiac surgery. It is associated with heart failure, renal insufficiency, systemic embolism and increase in days of in-hospital and mortality. Atrial fibrillation in the postoperative period of cardiac surgery (FAPCC) usually appears in the first 48 h after surgery. The main mechanisms involved in the appearance and maintenance of FAPCC are the increase in sympathetic tone and the inflammatory response. The associated risk factors are advanced age, chronic obstructive pulmonary disease, chronic kidney disease, valve surgery, fraction of ejection of the left ventricle < 40% and the withdrawal of beta-blocker drugs. There are instruments that have been shown to predict the appearance of FAPCC. Prophylactic treatment with beta-blockers and amiodarone, is associated with a decrease in the appearance of FAPCC. Given its transient nature, it is suggested that the initial treatment of FAPCC be the heart rate control and only if the treatment does not achieve a return to sinus rhythm, the use of electrical cardioversion is suggested. It is unknown what should be the long-term follow-up and complications beyond this period are little known. FAPCC is not a benign or isolated arrhythmia in patients undergoing cardiac surgery, so the identification of risk factors, their prevention, and follow-up in the outpatient setting, should be part of the units dedicated to the care and care of these patients.


La fibrilación auricular es la arritmia más frecuente en el periodo posquirúrgico de la cirugía cardíaca. Se relaciona con insuficiencia cardíaca, insuficiencia renal, embolismo sistémico y más días de estancia y mortalidad. La fibrilación auricular en el periodo posquirúrgico de la cirugía cardíaca (FAPCC) suele aparecer en las primeras 48 horas. Los principales mecanismos que producen la aparición y el mantenimiento de la FAPCC son el aumento del tono simpático y la respuesta inflamatoria. Los factores de riesgo adjuntos son la edad avanzada, enfermedad pulmonar obstructiva crónica, enfermedad renal crónica, cirugía valvular, fracción de expulsión del ventrículo izquierdo menor de 40% e interrupción de fármacos bloqueadores ß. Existen instrumentos que han demostrado predecir la aparición de FAPCC. El tratamiento profiláctico con bloqueadores ß y amiodarona se relaciona con disminución de la aparición de FAPCC. Dada su naturaleza transitoria, se sugiere que el tratamiento inicial de FAPCC sea el control de la frecuencia cardíaca y sólo en caso de que el tratamiento no consiga el retorno al ritmo sinusal está indicada la cardioversión eléctrica. Se desconoce cuál debe ser el seguimiento a largo plazo y sólo se conocen en escasa medida las complicaciones más allá de este periodo. La FAPCC no es una arritmia benigna ni aislada en los pacientes sometidos a operación cardíaca, por lo que la identificación de los factores de riesgo, su prevención y el seguimiento en el ámbito ambulatorio deben formar parte de las unidades dedicadas a la atención y los cuidados de estos pacientes.


Subject(s)
Atrial Fibrillation/etiology , Cardiac Surgical Procedures/methods , Postoperative Complications/epidemiology , Atrial Fibrillation/epidemiology , Atrial Fibrillation/therapy , Cardiac Surgical Procedures/adverse effects , Electric Countershock/methods , Humans , Risk Factors
20.
Arch. cardiol. Méx ; 89(4): 348-359, Oct.-Dec. 2019. tab
Article in Spanish | LILACS | ID: biblio-1149093

ABSTRACT

Resumen La fibrilación auricular es la arritmia más frecuente en el periodo posquirúrgico de la cirugía cardíaca. Se relaciona con insuficiencia cardíaca, insuficiencia renal, embolismo sistémico y más días de estancia y mortalidad. La fibrilación auricular en el periodo posquirúrgico de la cirugía cardíaca (FAPCC) suele aparecer en las primeras 48 horas. Los principales mecanismos que producen la aparición y el mantenimiento de la FAPCC son el aumento del tono simpático y la respuesta inflamatoria. Los factores de riesgo adjuntos son la edad avanzada, enfermedad pulmonar obstructiva crónica, enfermedad renal crónica, cirugía valvular, fracción de expulsión del ventrículo izquierdo menor de 40% e interrupción de fármacos bloqueadores β. Existen instrumentos que han demostrado predecir la aparición de FAPCC. El tratamiento profiláctico con bloqueadores β y amiodarona se relaciona con disminución de la aparición de FAPCC. Dada su naturaleza transitoria, se sugiere que el tratamiento inicial de FAPCC sea el control de la frecuencia cardíaca y sólo en caso de que el tratamiento no consiga el retorno al ritmo sinusal está indicada la cardioversión eléctrica. Se desconoce cuál debe ser el seguimiento a largo plazo y sólo se conocen en escasa medida las complicaciones más allá de este periodo. La FAPCC no es una arritmia benigna ni aislada en los pacientes sometidos a operación cardíaca, por lo que la identificación de los factores de riesgo, su prevención y el seguimiento en el ámbito ambulatorio deben formar parte de las unidades dedicadas a la atención y los cuidados de estos pacientes.


Abstract Atrial fibrillation is the most frequent arrhythmia in the postoperative period of cardiac surgery. It is associated with heart failure, renal insufficiency, systemic embolism and increase in days of in-hospital and mortality. Atrial fibrillation in the postoperative period of cardiac surgery (FAPCC) usually appears in the first 48 h after surgery. The main mechanisms involved in the appearance and maintenance of FAPCC are the increase in sympathetic tone and the inflammatory response. The associated risk factors are advanced age, chronic obstructive pulmonary disease, chronic kidney disease, valve surgery, fraction of ejection of the left ventricle less 40% and the withdrawal of beta-blocker drugs. There are instruments that have been shown to predict the appearance of FAPCC. Prophylactic treatment with beta-blockers and amiodarone, is associated with a decrease in the appearance of FAPCC. Given its transient nature, it is suggested that the initial treatment of FAPCC be the heart rate control and only if the treatment does not achieve a return to sinus rhythm, the use of electrical cardioversion is suggested. It is unknown what should be the long-term follow-up and complications beyond this period are little known. FAPCC is not a benign or isolated arrhythmia in patients undergoing cardiac surgery, so the identification of risk factors, their prevention, and follow-up in the outpatient setting, should be part of the units dedicated to the care and care of these patients.


Subject(s)
Humans , Postoperative Complications/epidemiology , Atrial Fibrillation/etiology , Cardiac Surgical Procedures/methods , Atrial Fibrillation/therapy , Atrial Fibrillation/epidemiology , Electric Countershock/methods , Risk Factors , Cardiac Surgical Procedures/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...