1.
Int J Mol Sci ; 24(18)2023 Sep 09.
Article in English | MEDLINE | ID: mdl-37762183

ABSTRACT

Screening patients for S. aureus nasal carriage has proved effective in preventing cross-contamination and endogenous infection with this bacterium. The aim of this study was to assess the performance of the BD MAX StaphSR assay with liquid Amies elution swabs, taken during routine care of intensive care unit patients. Direct and pre-enriched cultures were used as reference methods to screen for S. aureus and methicillin-resistant S. aureus (MRSA). Discrepant results between the BD MAX StaphSR assay and cultures were resolved by using the Xpert SA Nasal Complete assay. A total of 607 nasal swabs taken from 409 patients were included in this study. Compared to culture methods, the sensitivity and specificity of the BD MAX StaphSR assay were 92.5% and 91.7% for S. aureus screening, and 94.7% and 98.3% for MRSA screening, respectively. In 52 (8.6%) specimens, there was a discrepancy between the results of cultures and the BD MAX StaphSR assay, including 13 (25%) where the results of the BD MAX StaphSR assay were confirmed by the Xpert SA Nasal Complete test. This prospective study showed that the BD MAX StaphSR assay is reliable for S. aureus and MRSA detection from nasal samples taken with liquid Amies elution swabs.


Subject(s)
Methicillin-Resistant Staphylococcus aureus , Staphylococcal Infections , Humans , Staphylococcus aureus , Methicillin , Prospective Studies , Staphylococcal Infections/diagnosis , Staphylococcal Infections/microbiology , Sensitivity and Specificity , Intensive Care Units
2.
J Clin Microbiol ; 53(6): 1921-6, 2015 Jun.
Article in English | MEDLINE | ID: mdl-25878344

ABSTRACT

A multiplex real-time PCR (quantitative PCR [qPCR]) assay detecting herpes simplex virus (HSV) and varicella-zoster virus (VZV) DNA together with an internal control was developed on the BD Max platform combining automated DNA extraction and an open amplification procedure. Its performance was compared to those of PCR assays routinely used in the laboratory, namely, a laboratory-developed test for HSV DNA on the LightCycler instrument and a test using a commercial master mix for VZV DNA on the ABI7500fast system. Using a pool of negative cerebrospinal fluid (CSF) samples spiked with either calibrated controls for HSV-1 and VZV or dilutions of a clinical strain that was previously quantified for HSV-2, the empirical limit of detection of the BD Max assay was 195.65, 91.80, and 414.07 copies/ml for HSV-1, HSV-2, and VZV, respectively. All the samples from HSV and VZV DNA quality control panels (Quality Control for Molecular Diagnostics [QCMD], 2013, Glasgow, United Kingdom) were correctly identified by the BD Max assay. From 180 clinical specimens of various origins, 2 CSF samples were found invalid by the BD Max assay due to the absence of detection of the internal control; a concordance of 100% was observed between the BD Max assay and the corresponding routine tests. The BD Max assay detected the PCR signal 3 to 4 cycles earlier than did the routine methods. With results available within 2 h on a wide range of specimens, this sensitive and fully automated PCR assay exhibited the qualities required for detecting simultaneously HSV and VZV DNA on a routine basis.


Subject(s)
Herpesviridae Infections/diagnosis , Herpesvirus 3, Human/genetics , Molecular Typing/methods , Multiplex Polymerase Chain Reaction/methods , Real-Time Polymerase Chain Reaction/methods , Simplexvirus/genetics , DNA, Viral/cerebrospinal fluid , Herpesviridae Infections/virology , Humans , Limit of Detection , Reproducibility of Results , Retrospective Studies