Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-38501453

ABSTRACT

Objective: Test the feasibility, adherence rates and optimal frequency of digital, remote assessments using the ALSFRS-RSE via a customized smartphone-based app. Methods: This fully remote, longitudinal study was conducted over a 24-week period, with virtual visits every 3 months and weekly digital assessments. 19 ALS participants completed digital assessments via smartphone, including a digital version of the ALSFRS-RSE and mood survey. Interclass correlation coefficients (ICC) and Bland-Altman plots were used to assess agreement between staff-administered and self-reported ALSFRS-R pairs. Longitudinal change was evaluated using ANCOVA models and linear mixed models, including impact of mood and time of day. Impact of frequency of administration of the ALSFRS-RSE on precision of the estimate slope was tested using a mixed effects model. Results: In our ALS cohort, digital assessments were well-accepted and adherence was robust, with completion rates of 86%. There was excellent agreement between the digital self-entry and staff-administered scores computing multiple ICCs (ICC range = 0.925-0.961), with scores on the ALSFRS-RSE slightly higher (1.304 points). Digital assessments were associated with increased precision of the slope, resulting in higher standardized response mean estimates for higher frequencies, though benefit appeared to diminish at biweekly and weekly frequency. Effects of participant mood and time of day on total ALSFRS-RSE score were evaluated but were minimal and not statistically significant. Conclusion: Remote collection of digital patient-reported outcomes of functional status such as the ALSFRS-RSE yield more accurate estimates of change over time and provide a broader understanding of the lived experience of people with ALS.

2.
NPJ Digit Med ; 3: 6, 2020.
Article in English | MEDLINE | ID: mdl-31970291

ABSTRACT

Accurately monitoring motor and non-motor symptoms as well as complications in people with Parkinson's disease (PD) is a major challenge, both during clinical management and when conducting clinical trials investigating new treatments. A variety of strategies have been relied upon including questionnaires, motor diaries, and the serial administration of structured clinical exams like part III of the MDS-UPDRS. To evaluate the potential use of mobile and wearable technologies in clinical trials of new pharmacotherapies targeting PD symptoms, we carried out a project (project BlueSky) encompassing four clinical studies, in which 60 healthy volunteers (aged 23-69; 33 females) and 95 people with PD (aged 42-80; 37 females; years since diagnosis 1-24 years; Hoehn and Yahr 1-3) participated and were monitored in either a laboratory environment, a simulated apartment, or at home and in the community. In this paper, we investigated (i) the utility and reliability of self-reports for describing motor fluctuations; (ii) the agreement between participants and clinical raters on the presence of motor complications; (iii) the ability of video raters to accurately assess motor symptoms, and (iv) the dynamics of tremor, dyskinesia, and bradykinesia as they evolve over the medication cycle. Future papers will explore methods for estimating symptom severity based on sensor data. We found that 38% of participants who were asked to complete an electronic motor diary at home missed ~25% of total possible entries and otherwise made entries with an average delay of >4 h. During clinical evaluations by PD specialists, self-reports of dyskinesia were marked by ~35% false negatives and 15% false positives. Compared with live evaluation, the video evaluation of part III of the MDS-UPDRS significantly underestimated the subtle features of tremor and extremity bradykinesia, suggesting that these aspects of the disease may be underappreciated during remote assessments. On the other hand, live and video raters agreed on aspects of postural instability and gait. Our results highlight the significant opportunity for objective, high-resolution, continuous monitoring afforded by wearable technology to improve upon the monitoring of PD symptoms.

3.
IEEE Open J Eng Med Biol ; 1: 243-248, 2020.
Article in English | MEDLINE | ID: mdl-34192282

ABSTRACT

Goal: The aim of the study herein reported was to review mobile health (mHealth) technologies and explore their use to monitor and mitigate the effects of the COVID-19 pandemic. Methods: A Task Force was assembled by recruiting individuals with expertise in electronic Patient-Reported Outcomes (ePRO), wearable sensors, and digital contact tracing technologies. Its members collected and discussed available information and summarized it in a series of reports. Results: The Task Force identified technologies that could be deployed in response to the COVID-19 pandemic and would likely be suitable for future pandemics. Criteria for their evaluation were agreed upon and applied to these systems. Conclusions: mHealth technologies are viable options to monitor COVID-19 patients and be used to predict symptom escalation for earlier intervention. These technologies could also be utilized to monitor individuals who are presumed non-infected and enable prediction of exposure to SARS-CoV-2, thus facilitating the prioritization of diagnostic testing.

4.
Digit Biomark ; 3(2): 31-71, 2019.
Article in English | MEDLINE | ID: mdl-32095767

ABSTRACT

Technology is changing how we practice medicine. Sensors and wearables are getting smaller and cheaper, and algorithms are becoming powerful enough to predict medical outcomes. Yet despite rapid advances, healthcare lags behind other industries in truly putting these technologies to use. A major barrier to entry is the cross-disciplinary approach required to create such tools, requiring knowledge from many people across many fields. We aim to drive the field forward by unpacking that barrier, providing a brief introduction to core concepts and terms that define digital medicine. Specifically, we contrast "clinical research" versus routine "clinical care," outlining the security, ethical, regulatory, and legal issues developers must consider as digital medicine products go to market. We classify types of digital measurements and how to use and validate these measures in different settings. To make this resource engaging and accessible, we have included illustrations and figures throughout that we hope readers will borrow from liberally. This primer is the first in a series that will accelerate the safe and effective advancement of the field of digital medicine.

5.
Proc SPIE Int Soc Opt Eng ; 7896(1)2011 Jan 23.
Article in English | MEDLINE | ID: mdl-21572907

ABSTRACT

We have previously reported an optical response in human subjects occurring at 100 ms following electrical stimulation of peripheral nerves. In the present study, an animal model has been created to directly investigate the myogenic components of the signal. In addition, experiments have been performed in human subjects to investigate the signal's neuroanatomical specificity, sensitivity to muscle motion, and spatial and spectral features. The results of this work suggest that the observed optical signal derives from stimulus-induced motion associated with muscle contraction and likely contains myological information of clinical value.

6.
Biomed Opt Express ; 1(3): 923-942, 2010 Sep 16.
Article in English | MEDLINE | ID: mdl-21258519

ABSTRACT

Using non-invasive, near-infrared spectroscopy we have previously reported optical signals measured at or around peripheral nerves in response to their stimulation. Such optical signals featured amplitudes on the order of 0.1% and peaked about 100 ms after peripheral nerve stimulation in human subjects. Here, we report a study of the spatial and spectral dependence of the optical signals induced by stimulation of the human median and sural nerves, and observe that these optical signals are: (1) unlikely due to either dilation or constriction of blood vessels, (2) not associated with capillary bed hemoglobin, (3) likely due to blood vessel(s) displacement, and (4) unlikely due to fiber-skin optical coupling effects. We conclude that the most probable origin of the optical response to peripheral nerve stimulation is from displacement of blood vessels within the optically probed volume, as a result of muscle twitch in adjacent areas.

7.
Biomed Opt Express ; 1(3): 943-954, 2010 Sep 16.
Article in English | MEDLINE | ID: mdl-21258520

ABSTRACT

Previously we have reported a near-infrared optical response in the region occupied by a peripheral nerve that is distal to the site of electrical stimulation of that peripheral nerve. This "intermediate" signal is vascular in nature but its biological origin not been elucidated. In the present study, an animal model of the signal has been created and our human studies expanded to directly investigate the contribution of non-artifactual vascular motion induced by muscle contraction to the biological origin of this signal. Under non-invasive conditions during stimulation of the exposed sciatic nerve of the Sprague-Dawley rat, optical responses are robust. These signals can be abolished both pharmacologically and surgically using methods that eliminate muscle motion while leaving the electrophysiological health of the nerve intact. In human studies, signals that are elicited on stimulation of nerves containing motor axons, both within and outside the predicted imaging volume of the spectrometer, have similar temporal characteristics of those previously observed. Moreover, stimulation of sensory nerves alone does not elicit an optical response. These results strongly suggest that the intermediate signals are derived from stimulus-induced muscle contraction (whether via an innervating nerve or by direct stimulation) causing translational vascular motion within the optically interrogated region.

SELECTION OF CITATIONS
SEARCH DETAIL
...