Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Talanta ; 218: 121108, 2020 Oct 01.
Article in English | MEDLINE | ID: mdl-32797872

ABSTRACT

This work presents a new optical microfluidic paper biosensor for the detection of organophosphate pesticides and carbamate pesticides. The assay strip is composed of a paper support (1 × 17.6 mm) onto which acetylcholine esterase (AChE) and acetylcholine chloride (AChCl) are deposited, in such a way that there is a small hole between them that ensures that they only come into contact in the reaction zone when they are carried by a solution of the sample by lateral flow to the reaction zone containing bromocresol purple (BCP) as the pH indicator, immobilized by sol-gel. The sensor operates at room temperature and the rate of the inhibited reaction serves as an analytical signal, which is measured using a camera by quantifying the appropriate colour coordinate. Calibration curves were obtained for chlorpyrifos and carbaryl, with a useful concentration range from 0.24 to 20 µg L-1 for carbaryl and from 2.00 to 45 µg L-1 for chlorpyrifos. The detection limits were 0.24 and 2.00 µg L-1, respectively, and with reproducibility around 4.2-5.5%. The method was applied to the determination of pesticides in different water samples, with no sample preparation.


Subject(s)
Biosensing Techniques , Chlorpyrifos , Pesticides , Carbaryl , Microfluidics , Reproducibility of Results
2.
Anal Chem ; 89(3): 1697-1703, 2017 02 07.
Article in English | MEDLINE | ID: mdl-28208249

ABSTRACT

In this work we present a full-passive flexible multigas sensing tag for the determination of oxygen, carbon dioxide, ammonia, and relative humidity readable by a smartphone. This tag is based on near field communication (NFC) technology for energy harvesting and data transmission to a smartphone. The gas sensors show an optic response that is read through high-resolution digital color detectors. A white LED is used as the common optical excitation source for all the sensors. Only a reduced electronics with very low power consumption is required for the reading of the optical responses and data transmission to a remote user. An application for the Android operating system has been developed for the power supplying and data reception from the tag. The responses of the sensors have been calibrated and fitted to simple functions, allowing a fast prediction of the gases concentration. Cross-sensitivity has also been evaluated, finding that in most of the cases it is negligible or easily correctable using the rest of the readings. The election of the target gases has been due to their importance in the monitoring of modified atmosphere packaging. The resolutions and limits of detection measured are suitable for such kinds of applications.

3.
Anal Chim Acta ; 694(1-2): 128-35, 2011 May 23.
Article in English | MEDLINE | ID: mdl-21565313

ABSTRACT

A disposable optical tongue for the alkaline ions Na(I) and K(I) is described. The two-sensor layout prepared on a transparent support consists of non-specific polymeric membranes working by ionophore-chromoionophore chemistry. The non-specific behavior of the membranes was controlled by means of the crown ether-type ionophore present. The imaging of the tongue, after reaction for 3 min with the unknown solution, by means of a conventional flatbed scanner working by transmission mode, makes it possible to calculate the H (hue) value of the hue, saturation, value (HSV) color space used as a robust and precise analytical parameter. The modelling of the response of the two-sensor tongue as a sigmoidal surface is used to characterize the behavior of the tongue and as a basis to infer the concentration values. To compute the concentration of two analytes from the two hue values obtained using the optical tongue, a surface fit approach was used. The tongue works over a wide dynamic range (1.0×10(-4)-0.1 M both in Na(I) and K(I)). The sensing membranes show good intramembrane (1.4% RSD) and intermembrane precision (0.71% RSD) and lifetime (around 45 days in darkness). The procedure was used to analyze Na(I) and K(I) in different types of natural waters (tap and mineral), validating the results against a reference procedure.

4.
Anal Chem ; 82(2): 531-42, 2010 Jan 15.
Article in English | MEDLINE | ID: mdl-20000770

ABSTRACT

The hue or H component of the hue, saturation, value (HSV) color space has been studied as a quantitative analytical parameter for bitonal optical sensors. The robust nature of this parameter provides superior precision for the measurement of sensors which change colors with the speciation of some indicator molecule. This parameter has been compared to red, green, blue (RGB) intensity and RGB absorbance along with differences and ratios of both intensity and absorbance and has been demonstrated to be 2 to 3 times superior. The H value maintains this superior precision with variations in indicator concentration, membrane thickness, detector spectral responsivity, and illumination. Because this parameter is stable, simple to calculate, easily obtained from commercial devices such as scanners and digital cameras, continuous over the entire color gamut, and bound between values of 0 and 1, it shows great promise for use in a variety of sensing applications including imaging, automated analysis, pharmaceutical sensing, lab-on-a-chip devices, and quality control applications.

SELECTION OF CITATIONS
SEARCH DETAIL
...