1.
J Acoust Soc Am ; 149(4): 2137, 2021 Apr.
Article in English | MEDLINE | ID: mdl-33940872

ABSTRACT

The capacitive micromachined ultrasonic transducer (CMUT) has inherent advantages, such as larger bandwidth and monolithic integration capability with electronics, when compared to the piezoelectric transducer. The most significant shortcoming of the device is the trade-off between input and output sensitivities. Adequate receive sensitivity requires an electric field intensity on the order of 105 V/m, which can be achieved by sub-micron gap heights. However, a small gap limits the device stroke and, consequently, the maximum output pressure. This paper addresses this problem by proposing a CMUT with a vertical cavity. The membrane of the device has a piston part that is surrounded by the sidewalls of a vertical cylinder formed in the substrate. The fringing electric field pulls the piston in the vertical direction; hence, the gap height remains fixed, which alleviates the hard limit on device stroke. The performance of the proposed device is compared to that of the conventional CMUT by theoretical and analytical methods, and a micro-fabrication method is devised. Additionally, a millimeter-scale device has been manufactured and tested as a proof of concept.

2.
Ultrasonics ; 51(7): 786-94, 2011 Oct.
Article in English | MEDLINE | ID: mdl-21459399

ABSTRACT

Focused ultrasound therapy relies on acoustic power absorption by tissue. The stronger the absorption the higher the temperature increase is. However, strong acoustic absorption also means faster attenuation and limited penetration depth. Hence, there is a trade-off between heat generation efficacy and penetration depth. In this paper, we formulated the acoustic power absorption as a function of frequency and attenuation coefficient, and defined two figures of merit to measure the power absorption: spatial peak of the acoustic power absorption density, and the acoustic power absorbed within the focal area. Then, we derived "rule of thumb" expressions for the optimum frequencies that maximized these figures of merit given the target depth and homogeneous tissue type. We also formulated a method to calculate the optimum frequency for inhomogeneous tissue given the tissue composition for situations where the tissue structure can be assumed to be made of parallel layers of homogeneous tissue. We checked the validity of the rules using linear acoustic field simulations. For a one-dimensional array of 4cm acoustic aperture, and for a two-dimensional array of 4×4cm(2) acoustic aperture, we found that the power absorbed within the focal area is maximized at 0.86MHz, and 0.79MHz, respectively, when the target depth is 4cm in muscle tissue. The rules on the other hand predicted the optimum frequencies for acoustic power absorption as 0.9MHz and 0.86MHz, respectively for the 1D and 2D array case, which are within 6% and 9% of the field simulation results. Because radiation force generated by an acoustic wave in a lossy propagation medium is approximately proportional to the acoustic power absorption, these rules can be used to maximize acoustic radiation force generated in tissue as well.


Subject(s)
Transducers , Ultrasonic Therapy/instrumentation , Ultrasonic Therapy/methods , Acoustics , Computer Simulation , Equipment Design , Mathematics , Models, Theoretical , Temperature
3.
Article in English | MEDLINE | ID: mdl-19213640

ABSTRACT

Capacitive micromachined ultrasonic transducers (CMUTs) featuring piston-shaped membranes (piston CMUTs) were developed to improve device performance in terms of transmission efficiency, reception sensitivity, and fractional bandwidth (FBW). A piston CMUT has a relatively flat active moving surface whose membrane motion is closer to ideal piston-type motion compared with a CMUT with uniformly thick membranes (classical CMUT). Piston CMUTs with a more uniform surface displacement profile can achieve high output pressure with a relatively small electrode separation. The improved device capacitance and gap uniformity also enhance detection sensitivity. By adding a center mass to the membrane, a large ratio of second-order resonant frequency to first-order resonant frequency was achieved. This improved the FBW. Piston CMUTs featuring membranes of different geometric shapes were designed and fabricated using wafer bonding. Fabricating piston CMUTs is a more complex process than fabricating CMUTs with uniformly thick membranes. However, no yield loss was observed. These devices achieved ~100% improvement in transduction performance (transmission and reception) over classical CMUTs. For CMUTs with square and rectangular membranes, the FBW increased from ~110% to ~150% and from ~140% to ~175%, respectively, compared with classical CMUTs. The new devices produced a maximum output pressure exceeding 1 MPa at the transducer surface. Performance optimization using geometric membrane shape configurations was the same in both piston CMUTs and classical CMUTs.


Subject(s)
Micro-Electrical-Mechanical Systems/instrumentation , Transducers , Ultrasonics , Computer Simulation , Electric Capacitance , Equipment Design , Membranes, Artificial , Sensitivity and Specificity , Silicon/chemistry
4.
Ultrasonics ; 48(1): 74-81, 2008 Mar.
Article in English | MEDLINE | ID: mdl-18207212

ABSTRACT

In this paper, an improved design of a capacitive micromachined ultrasonic transducer (CMUT) is presented. The design improvement aims to address the reliability issues of a CMUT and to extend the device operation beyond the contact (collapse) voltage. The major design novelty is the isolation posts in the vacuum cavities of the CMUT cells instead of full-coverage insulation layers in conventional CMUTs. This eliminates the contact voltage drifting due to charging caused by the insulation layer, and enables repeatable CMUT operation in the post-contact regime. Ultrasonic tests of the CMUTs with isolation posts (PostCMUTs) in air (electrical input impedance and capacitance vs. bias voltage) and immersion (transmission and reception) indicate acoustic performance similar to that obtained from conventional CMUTs while no undesired side effects of this new design is observed.


Subject(s)
Computer-Aided Design , Microelectrodes , Transducers , Ultrasonography/instrumentation , Calibration , Computer Simulation , Electric Capacitance , Electronics, Medical , Equipment Design , Equipment Failure Analysis , Miniaturization
5.
Article in English | MEDLINE | ID: mdl-19126489

ABSTRACT

Minimally invasive catheter-based electrophysiological (EP) interventions are becoming a standard procedure in diagnosis and treatment of cardiac arrhythmias. As a result of technological advances that enable small feature sizes and a high level of integration, nonfluoroscopic intracardiac echocardiography (ICE) imaging catheters are attracting increasing attention. ICE catheters improve EP procedural guidance while reducing the undesirable use of fluoroscopy, which is currently the common catheter guidance method. Phased-array ICE catheters have been in use for several years now, although only for side-looking imaging. We are developing a forward-looking ICE catheter for improved visualization. In this effort, we fabricate a 24-element, fine-pitch 1-D array of capacitive micromachined ultrasonic transducers (CMUT), with a total footprint of 1.73 mm x 1.27 mm. We also design a custom integrated circuit (IC) composed of 24 identical blocks of transmit/ receive circuitry, measuring 2.1 mm x 2.1 mm. The transmit circuitry is capable of delivering 25-V unipolar pulses, and the receive circuitry includes a transimpedance preamplifier followed by an output buffer. The CMUT array and the custom IC are designed to be mounted at the tip of a 10-Fr catheter for high-frame-rate forward-looking intracardiac imaging. Through-wafer vias incorporated in the CMUT array provide access to individual array elements from the back side of the array. We successfully flip-chip bond a CMUT array to the custom IC with 100% yield. We coat the device with a layer of polydimethylsiloxane (PDMS) to electrically isolate the device for imaging in water and tissue. The pulse-echo in water from a total plane reflector has a center frequency of 9.2 MHz with a 96% fractional bandwidth. Finally, we demonstrate the imaging capability of the integrated device on commercial phantoms and on a beating ex vivo rabbit heart (Langendorff model) using a commercial ultrasound imaging system.


Subject(s)
Cardiac Catheterization/instrumentation , Electronics/instrumentation , Ultrasonography/instrumentation , Animals , Echocardiography/instrumentation , Electrophysiologic Techniques, Cardiac/instrumentation , Equipment Design , Humans , Image Interpretation, Computer-Assisted/instrumentation , Phantoms, Imaging , Rabbits , Transducers
6.
Article in English | MEDLINE | ID: mdl-16921904

ABSTRACT

This paper reports on the experimental characterization of collapse-mode operation of capacitive micromachined ultrasonic transducers (CMUTs). CMUTs are conventionally operated by applying a direct current (DC) bias voltage less than the collapse voltage of the membrane, so that the membrane is deflected toward the bottom electrode. In the conventional regime, there is no contact between the membrane and the substrate; the maximum alternating current (AC) displacement occurs at the center of the membrane. In collapse-mode operation, the DC bias voltage is first increased beyond the collapse voltage, then reduced without releasing the collapsed membrane. In collapse-mode operation, the center of the membrane is always in contact with the substrate. In the case of a circular membrane, the maximum AC displacement occurs along the ring formed between the center and the edge of the membrane. The experimental characterization presented in this paper includes impedance measurements in air, pulse-echo experiments in immersion, and one-way optical displacement measurements in immersion for both conventional and collapse-mode operations. A 205-microm x 205-microm 2-D CMUT array element composed of circular silicon nitride membranes is used in the experiments. In pulse-echo experiments, a custom integrated circuit (IC) comprising a pulse driver, a transmit/receive switch, a wideband low-noise preamplifier, and a line driver is used. By reducing the parasitic capacitance, the use of a custom IC enables pulse-echo measurements at high frequencies with a very small transducer. By comparing frequency response and efficiency of the transducer in conventional and collapse regimes, experimental results show that a collapsed membrane can be used to generate and detect ultrasound more efficiently than a membrane operated in the conventional mode. Furthermore, the center frequency of the collapsed membrane can be changed by varying the applied DC voltage. In this study, the center frequency of a collapsed transducer in immersion is shown to vary from 20 MHz to 28 MHz with applied DC bias; the same transducer operates at 10 MHz in the conventional mode. In conventional mode, the maximum peak-to-peak pressure is 370 kPa on the transducer surface for a 40-ns, 25-V unipolar pulse excitation. In collapse mode, a 25-ns, 25-V unipolar pulse generates 590 kPa pressure at the surface of the transducer.

7.
Article in English | MEDLINE | ID: mdl-15801320

ABSTRACT

Capacitive micromachined ultrasonic transducers (cMUTs) were developed to meet the demands of the ultrasonic industry. To achieve maximum efficiency, the conventional operation of the cMUT requires a bias voltage close to the collapse voltage. Total acoustic output pressure is limited by the efficiency of the cMUT and the maximum-allowed pulse voltage on the membrane. In this paper, we propose the collapse-snapback operation of the cMUT: the membrane is collapsed onto the substrate in the collapsing cycle, and released in the snapback cycle. The collapse-snapback operation overcomes the above-mentioned limitations of the conventional operation. The collapse-snapback operation utilizes a larger range of membrane deflection profiles (both collapsed and released profiles) and generates higher acoustic output pressures. The static finite element calculations were performed to design cMUTs with specific collapse and snapback voltages by changing the electrode parameters (radius (re), position (de), and thickness (te)). These designs were refined for optimum average displacement per cycle. An electrode radius greater than 60% of the membrane radius significantly improved the displacement per volt. Moderately thick membranes (te approximately 0.2 microm) were preferred, as thicker membranes reduced the displacement per volt. Under proper bias conditions, the collapse-snapback operation, designed for high-power transmission, allowed the application of pulse voltages larger than the difference of collapse and snapback voltages. Dynamic finite element calculations of an infinite cMUT array on the substrate loaded with acoustic fluid medium were performed to determine the dynamic response of the cMUT. Commercially available FEM packages ANSYS and LS-DYNA were used for static and dynamic calculations, respectively. The cMUTs were fabricated for optimal performance in the collapse-snapback operation. The transmit experiments were performed on a 2-D cMUT array using a calibrated hydrophone. Taking into account the attenuation and diffraction losses, the pressure on the cMUT surface was extracted. The cMUT generated 0.47 MPa (6 kPa/V) and 1.04 MPa (11 kPa/V) in the conventional and collapse-snapback operations, respectively. Therefore, collapse-snapback operation of the cMUTs was superior for high-power transmission.

8.
Article in English | MEDLINE | ID: mdl-16463485

ABSTRACT

In this paper, we present the results of finite-element analysis performed to investigate capacitive micromachined ultrasonic transducers (CMUTs). Both three-dimensional (3-D) and 2-D models were developed using a commercially available finite-element modeling (FEM) software. Depending on the dimensionality of the model, the membranes were constructed using plane or shell elements. The electrostatic gap was modeled using many parallel plate transducers. An axisymmetric model for a single membrane was built; the electrical input impedance of the device then was calculated in vacuum to investigate series and parallel resonant frequencies, where the input impedance has a minimum and a maximum, respectively. A method for decomposing the membrane capacitance into parasitic and active parts was demonstrated, and it was shown that the parallel resonant frequency shifted down with increased biased voltage. Calculations then were performed for immersion transducers. Acoustic wave propagation was simulated in the immersion medium, using appropriate elements in a 3-D model. Absorbing boundaries were implemented to avoid the reflections at the end of the medium mesh. One row of an array element, modeled with appropriate boundary conditions, was used to calculate the output pressure. The results were compared with a simpler model: a single membrane in immersion, with symmetry boundary conditions on the sidewalls that cause the calculations to reflect the properties of an infinitely large array. A 2-D model then was developed to demonstrate the effect of membrane dimensions on the output pressure and bandwidth. Our calculations revealed that the small signal transmit pressure was inversely proportional to the square root of gap height. We also compared FEM results with analytical and experimental results.


Subject(s)
Computer-Aided Design , Linear Models , Membranes, Artificial , Transducers , Ultrasonography/instrumentation , Computer Simulation , Electric Capacitance , Electronics, Medical , Equipment Design , Equipment Failure Analysis , Finite Element Analysis , Miniaturization , Ultrasonography/methods
9.
Article in English | MEDLINE | ID: mdl-16463492

ABSTRACT

Electrostatic transducers are usually operated under a DC bias below their collapse voltage. The same scheme has been adopted for capacitive micromachined ultrasonic transducers (cMUTs). DC bias deflects the cMUT membranes toward the substrate, so that their centers are free to move during both receive and transmit operations. In this paper, we present time-domain, finite element calculations for cMUTs using LS-DYNA, a commercially available finite element package. In addition to this DC bias mode, other new cMUT operations (collapse and collapse-snapback) have recently been demonstrated. Because cMUT membranes make contact with the substrate in these new operations, modeling of these cMUTs should include contact analysis. Our model was a cMUT transducer consisting of many hexagonal membranes; because it was symmetrical, we modeled only one-sixth of a hexagonal cell loaded with a fluid medium. The finite element results for both conventional and collapse modes were compared to measurements made by an optical interferometer; a good match was observed. Thus, the model is useful for designing cMUTs that operate in regimes where membranes make contact with the substrate.


Subject(s)
Computer-Aided Design , Electric Capacitance , Linear Models , Membranes, Artificial , Microelectrodes , Transducers , Ultrasonography/instrumentation , Computer Simulation , Electronics, Medical , Equipment Design , Equipment Failure Analysis , Finite Element Analysis , Miniaturization , Ultrasonography/methods
10.
Article in English | MEDLINE | ID: mdl-14682642

ABSTRACT

Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as a candidate to overcome the difficulties in the realization of 2-D arrays for real-time 3-D imaging. In this paper, we present the first volumetric images obtained using a 2-D CMUT array. We have fabricated a 128 x 128-element 2-D CMUT array with through-wafer via interconnects and a 420-microm element pitch. As an experimental prototype, a 32 x 64-element portion of the 128 x 128-element array was diced and flip-chip bonded onto a glass fanout chip. This chip provides individual leads from a central 16 x 16-element portion of the array to surrounding bondpads. An 8 x 16-element portion of the array was used in the experiments along with a 128-channel data acquisition system. For imaging phantoms, we used a 2.37-mm diameter steel sphere located 10 mm from the array center and two 12-mm-thick Plexiglas plates located 20 mm and 60 mm from the array. A 4 x 4 group of elements in the middle of the 8 x 16-element array was used in transmit, and the remaining elements were used to receive the echo signals. The echo signal obtained from the spherical target presented a frequency spectrum centered at 4.37 MHz with a 100% fractional bandwidth, whereas the frequency spectrum for the echo signal from the parallel plate phantom was centered at 3.44 MHz with a 91% fractional bandwidth. The images were reconstructed by using RF beamforming and synthetic phased array approaches and visualized by surface rendering and multiplanar slicing techniques. The image of the spherical target has been used to approximate the point spread function of the system and is compared with theoretical expectations. This study experimentally demonstrates that 2-D CMUT arrays can be fabricated with high yield using silicon IC-fabrication processes, individual electrical connections can be provided using through-wafer vias, and flip-chip bonding can be used to integrate these dense 2-D arrays with electronic circuits for practical 3-D imaging applications.


Subject(s)
Image Interpretation, Computer-Assisted/instrumentation , Image Interpretation, Computer-Assisted/methods , Imaging, Three-Dimensional/instrumentation , Imaging, Three-Dimensional/methods , Transducers , Ultrasonography/instrumentation , Ultrasonography/methods , Algorithms , Equipment Failure Analysis , Image Enhancement/instrumentation , Image Enhancement/methods , Nucleocapsid Proteins , Phantoms, Imaging
11.
Article in English | MEDLINE | ID: mdl-14561035

ABSTRACT

This paper details the theory, fabrication, and characterization of a new Lamb wave device. Built using capacitive micromachined ultrasonic transducers (CMUTs), the structure described uses rectangular membranes to excite and receive Lamb waves on a silicon substrate. An equivalent circuit model for the transducer is proposed that produces results, which match well with those observed by experiment. During the derivation of this model, emphasis is placed on the resistance presented to the transducer membranes by the Lamb wave modes. Finite element analysis performed in this effort shows that the dominant propagating mode in the device is the lowest order antisymmetric flexural wave (A0). Furthermore, most of the power that couples into the Lamb wave is due to energy in the vibrating membrane that is transferred to the substrate through the supporting posts of the device. The manufacturing process of the structure, which relies solely on fundamental IC-fabrication techniques, is also discussed. The resulting device has an 18-microm-thick substrate that is almost entirely made up of crystalline silicon and operates at a frequency of 2.1 MHz. The characterization of this device includes S-parameter and laser vibrometer measurements as well as delay-line transmission data. The insertion loss, as determined by both S-parameter and delay-line transmission measurements, is 20 dB at 2.1 MHz. When configured as a delay-line oscillator, the device functions well as a sensor with sensitivity to changes in the mass loading of its substrate.

12.
Article in English | MEDLINE | ID: mdl-12484483

ABSTRACT

Piezoelectric materials have dominated the ultrasonic transducer technology. Recently, capacitive micromachined ultrasonic transducers (CMUTs) have emerged as an alternative technology offering advantages such as wide bandwidth, ease of fabricating large arrays, and potential for integration with electronics. The aim of this paper is to demonstrate the viability of CMUTs for ultrasound imaging. We present the first pulse-echo phased array B-scan sector images using a 128-element, one-dimensional (1-D) linear CMUT array. We fabricated 64- and 128-element 1-D CMUT arrays with 100% yield and uniform element response across the arrays. These arrays have been operated in immersion with no failure or degradation in performance over the time. For imaging experiments, we built a resolution test phantom roughly mimicking the attenuation properties of soft tissue. We used a PC-based experimental system, including custom-designed electronic circuits to acquire the complete set of 128 x 128 RF A-scans from all transmit-receive element combinations. We obtained the pulse-echo frequency response by analyzing the echo signals from wire targets. These echo signals presented an 80% fractional bandwidth around 3 MHz, including the effect of attenuation in the propagating medium. We reconstructed the B-scan images with a sector angle of 90 degrees and an image depth of 210 mm through offline processing by using RF beamforming and synthetic phased array approaches. The measured 6-dB lateral and axial resolutions at 135 mm depth were 0.0144 radians and 0.3 mm, respectively. The electronic noise floor of the image was more than 50 dB below the maximum mainlobe magnitude. We also performed preliminary investigations on the effects of crosstalk among array elements on the image quality. In the near field, some artifacts were observable extending out from the array to a depth of 2 cm. A tail also was observed in the point spread function (PSF) in the axial direction, indicating the existence of crosstalk. The relative amplitude of this tail with respect to the mainlobe was less than -20 dB.


Subject(s)
Artifacts , Electric Capacitance , Electrodes , Image Enhancement/methods , Transducers , Ultrasonography/instrumentation , Adipose Tissue/diagnostic imaging , Algorithms , Computer Simulation , Equipment Design , Liver/diagnostic imaging , Miniaturization , Phantoms, Imaging , Quality Control , Sensitivity and Specificity , Signal Processing, Computer-Assisted , Stochastic Processes