Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
BMC Oral Health ; 23(1): 457, 2023 07 07.
Article in English | MEDLINE | ID: mdl-37420199

ABSTRACT

BACKGROUND: This is the first study to report both cortical and trabecular bone evaluation of mandibles in bruxers, within the knowledge of the authors. The purpose of this study was to evaluate the effects of bruxism on both the cortical and the trabecular bone in antegonial and gonial regions of the mandible, which is the attachment of the masticatory muscles, by using panoramic radiographic images. METHODS: In this study, the data of 65 bruxer (31 female, 34 male) and 71 non-bruxer (37 female, 34 male) young adult patients (20-30 years) were evaluated. Antegonial Notch Depth (AND), Antegonial-Index (AI), Gonial-Index, Fractal Dimension (FD) and Bone Peaks (BP) were evaluated on panoramic radiographic images. The effects of the bruxism, gender and side factors were investigated according to these findings. The statistical significance level was set atP ≤ 0.05. RESULTS: The mean AND of bruxers (2.03 ± 0.91) was significantly higher than non-bruxers (1.57 ± 0.71; P < 0.001). The mean AND of males was significantly higher than females on both sides (P < 0.05). The mean AI of bruxers (2.95 ± 0.50) was significantly higher than non-bruxers (2.77 ± 0.43; P = 0.019). The mean FD on each side was significantly lower in bruxers than in non-bruxers (P < 0.05). The mean FD of males (1.39 ± 0.06) was significantly higher than females (1.37 ± 0.06; P = 0.049). BP were observed in 72.5% of bruxers and 27.5% of non-bruxers. The probability of existing BP, in bruxers was approximately 3.4 times higher than in non-bruxers (P = 0.003), in males was approximately 5.5 times higher than in females (P < 0.001). CONCLUSION: According to the findings of this study, the morphological differences seen in cortical and trabecular bone in the antegonial and gonial regions of the mandible in bruxers can be emphasized as deeper AND, higher AI, increased of existing BPs, and lower FD, respectively. The appearance of these morphological changes on radiographs may be useful for indication and follow-up of bruxism. Gender is an effective factor on AND, existing BP and FD.


Subject(s)
Bruxism , Young Adult , Humans , Male , Female , Bruxism/diagnostic imaging , Radiography, Panoramic , Radiography , Cancellous Bone , Mandible/diagnostic imaging
2.
Clin Oral Investig ; 25(10): 5735-5741, 2021 Oct.
Article in English | MEDLINE | ID: mdl-33704572

ABSTRACT

OBJECTIVE: This study aims to compare the radiopacities of computer-aided design/computer-aided manufacture (CAD/CAM) blocks and the adhesive cements used for their bonding. MATERIALS AND METHODS: 1 ± 0.2 mm thick specimens were obtained from six different CAD/CAM blocks (Incoris TZI, IPS e.max CAD, Vita Mark II, Cerasmart, Vita Enamic, and Vita Suprinity), four different adhesive resin cements (Panavia F2.0, Variolink Esthetic DC, RelyX Unicem Aplicap, G-CEM LinkAce), and a tooth. Radiographs of the specimens from each group, a tooth section, and an aluminum (Al) step-wedge were acquired. The radiopacity values of the materials were calculated as equivalents of Al thickness using the gray level values. The data were statistically analyzed using one-way ANOVA and Tukey HSD tests. RESULTS: All the materials except Cerasmart and Vita Enamic had significantly higher radiopacity values than dentin (p < 0.05). Of the assessed blocks, the highest radiopacity value was observed in Incoris TZI, and the lowest radiopacity value was observed in Vita Enamic. Variolink Esthetic DC and RelyX Unicem Aplicap showed significantly higher radiopacity (p < 0.05) than the other adhesive cements, including enamel and dentin. CONCLUSIONS: In this study, the majority of the CAD/CAM materials and all the adhesive resin cements were found to have sufficient radiopacity for prosthetic restorations according to the criteria set by the International Organization for Standardization (ISO). CLINICAL RELEVANCE: From a clinical and biological point of view, materials should be chosen according to their radiopacity and other properties, such as biocompatibility and esthetics. If the selected restorative CAD/CAM blocks have a radiopacity value less than or equal to dentin, cements with higher radiopacity values are recommended to facilitate radiological diagnoses for periphery and interface of restorations.


Subject(s)
Esthetics, Dental , Resin Cements , Ceramics , Computer-Aided Design , Dental Porcelain , Materials Testing , Radiography, Dental, Digital , Surface Properties
SELECTION OF CITATIONS
SEARCH DETAIL
...