1.
Magn Reson Med ; 81(1): 719-729, 2019 01.
Article in English | MEDLINE | ID: mdl-30058220

ABSTRACT

PURPOSE: The aim of this study was to compare prospective head motion correction and motion tracking abilities of two tracking systems: Active NMR field probes and a Moiré phase tracking camera system using an optical marker. METHODS: Both tracking systems were used simultaneously on human subjects. The prospective head motion correction was compared in an MP2RAGE and a gradient echo sequence. In addition, the motion tracking trajectories for three subjects were compared against each other and their correlation and deviations were analyzed. RESULTS: With both tracking systems motion artifacts were visibly reduced. The precision of the field probe system was on the order of 50 µm for translations and 0.03° for rotations while the camera's was approximately 5 µm and 0.007°. The comparison of the measured trajectories showed close correlation and an average absolute deviation below 500 µm and 0.5°. CONCLUSION: This study presents the first in vivo comparison between NMR field probes and Moiré phase tracking. For the gradient echo images, the field probes had a similar motion correction performance as the optical tracking system. For the MP2RAGE measurement, however, the camera yielded better results. Still, both tracking systems substantially decreased image artifacts in the presence of subject motion. Thus, the motion tracking modality should be chosen according to the specific requirements of the experiment while considering the desired image resolution, refresh rate, and head coil constraints.


Subject(s)
Bites and Stings/diagnostic imaging , Head Movements , Head/diagnostic imaging , Magnetic Resonance Spectroscopy , Optical Devices , Adult , Algorithms , Artifacts , Calibration , Equipment Design , Humans , Male , Mouth/diagnostic imaging , Optics and Photonics , Reproducibility of Results , Signal-To-Noise Ratio
2.
Magn Reson Med ; 80(1): 380-390, 2018 07.
Article in English | MEDLINE | ID: mdl-29159823

ABSTRACT

PURPOSE: Knowledge of the positions of field probes in an NMR field camera is necessary for monitoring the B0 field. The typical method of estimating these positions is by switching the gradients with known strengths and calculating the positions using the phases of the FIDs. We investigated improving the accuracy of estimating the probe positions and analyzed the effect of inaccurate estimations on field monitoring. METHODS: The field probe positions were estimated by 1) assuming ideal gradient fields, 2) using measured gradient fields (including nonlinearities), and 3) using measured gradient fields with relative position constraints. The fields measured with the NMR field camera were compared to fields acquired using a dual-echo gradient recalled echo B0 mapping sequence. Comparisons were done for shim fields from second- to fourth-order shim terms. RESULTS: The position estimation was the most accurate when relative position constraints were used in conjunction with measured (nonlinear) gradient fields. The effect of more accurate position estimates was seen when compared to fields measured using a B0 mapping sequence (up to 10%-15% more accurate for some shim fields). The models acquired from the field camera are sensitive to noise due to the low number of spatial sample points. CONCLUSION: Position estimation of field probes in an NMR camera can be improved using relative position constraints and nonlinear gradient fields. Magn Reson Med 80:380-390, 2018. © 2017 International Society for Magnetic Resonance in Medicine.


Subject(s)
Calibration , Magnetic Resonance Spectroscopy/methods , Algorithms , Computer Simulation , Equipment Design , Humans , Image Processing, Computer-Assisted/methods , Linear Models , Magnetic Resonance Imaging/methods , Reference Values , Reproducibility of Results