1.
Circ Cardiovasc Interv ; 5(6): 831-40, 2012 Dec.
Article in English | MEDLINE | ID: mdl-23192918

ABSTRACT

BACKGROUND: Peripheral percutaneous transluminal angioplasty is fraught with a substantial risk of restenosis and reintervention. A drug-eluting balloon (DEB) based on a novel coating was compared with uncoated balloons in patients undergoing femoro-popliteal percutaneous transluminal angioplasty. METHODS AND RESULTS: Patients with symptomatic femoro-popliteal atherosclerotic disease undergoing percutaneous transluminal angioplasty were randomized to paclitaxel-coated IN.PACT Pacific or uncoated Pacific balloons. The primary end point was late lumen loss at 6 months assessed by blinded angiographic corelab quantitative analyses. Secondary end points were binary restenosis and Rutherford class change at 6 months, and target lesion revascularization plus major adverse clinical events (major adverse events=death, target limb amputation, or target lesion revascularization) at 6 and 12 months. Eighty-five patients (91 cases=interventional procedures) were randomized in 3 hospitals (44 to DEB and 47 to uncoated balloons). Average lesion length was 7.0 ± 5.3 and 6.6 ± 5.5 cm for DEB and control arm, respectively. Procedural success was obtained in all cases. Six-month quantitative angiography showed that DEB were associated with significantly lower late lumen loss (-0.01 mm [95% CI, -0.29; 0.26] versus 0.65 mm [0.37; 0.93], P=0.001) and fewer binary restenoses (3 [8.6%] versus 11 [32.4%], P=0.01). This translated into a clinically relevant benefit with significantly fewer major adverse events for DEB versus uncoated balloons up to 12 months (3 [7.1%] versus 15 [34.9%], P<0.01) as well as target lesion revascularizations (3 [7.1%] versus 12 [27.9%], P=0.02). CONCLUSIONS: Use of IN.PACT Pacific DEB is associated with significant reductions in late lumen loss and restenoses at 6 months, and reinterventions after femoro-popliteal percutaneous transluminal angioplasty up to 1 year of follow-up. CLINICAL TRIAL REGISTRATION: URL http://www.clinicaltrials.gov. Unique identifier: NCT01083030.


Subject(s)
Angioplasty, Balloon/instrumentation , Arterial Occlusive Diseases/therapy , Cardiovascular Agents/administration & dosage , Coated Materials, Biocompatible , Drug Carriers , Femoral Artery , Paclitaxel/administration & dosage , Popliteal Artery , Vascular Access Devices , Aged , Aged, 80 and over , Amputation, Surgical , Angioplasty, Balloon/adverse effects , Angioplasty, Balloon/mortality , Arterial Occlusive Diseases/diagnostic imaging , Arterial Occlusive Diseases/mortality , Chi-Square Distribution , Constriction, Pathologic , Equipment Design , Female , Femoral Artery/diagnostic imaging , Germany , Humans , Kaplan-Meier Estimate , Likelihood Functions , Linear Models , Male , Middle Aged , Popliteal Artery/diagnostic imaging , Proportional Hazards Models , Radiography , Secondary Prevention , Time Factors , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...