Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Appl Spectrosc ; 65(7): 806-16, 2011 Jul.
Article in English | MEDLINE | ID: mdl-21740643

ABSTRACT

This work describes a fast and reliable method for determination of photoionization cross-sections (PICS) by means of gas chromatography (GC) coupled to single-photon ionization mass spectrometry (SPI-MS). Photoionization efficiency (PIE) data for 69 substances was obtained at a photon energy of 9.8 ± 0.4 eV using an innovative electron-beam-pumped rare gas excimer light source (EBEL) filled with argon. The investigated analytes comprise 12 alkylbenzenes as well as 11 other substituted benzenes, 23 n-alkanes, ten polyaromatic hydrocarbons, seven aromatic heterocycles, and six polyaromatic heterocycles. Absolute PICS for each substance at 9.8 eV are calculated from the relative photoionization efficiencies of the compounds with respect to benzene, whose photoionization cross-section data is well known. Furthermore, a direct correlation between the type of benzene substituents and their absolute PICS is presented and discussed in depth. Finally, comparison of previously measured photoionization cross-sections for 20 substances shows good agreement with the data of the present work.

2.
Anal Chem ; 83(17): 6619-27, 2011 Sep 01.
Article in English | MEDLINE | ID: mdl-21699253

ABSTRACT

This work presents the direct coupling of a custom-made smoking machine (SM) to fast gas chromatography combined with single-photon ionization mass spectrometry (GC × SPI-MS) utilizing a six-port, two-position valve for online puff-resolved comprehensive two-dimensional investigation of cigarette smoke. The innovative electron-beam pumped rare gas excimer light source (EBEL) filled with argon provided vacuum ultraviolet (VUV) photons of 9.8 ± 0.4 eV (126 ± 9 nm) for SPI. Puff-by-puff quantification of 14 hazardous volatile organic smoke constituents from the 2R4F Kentucky research cigarette was enabled for two smoking regimes, i.e., ISO and Canadian Intense, after determination of photoionization cross sections. The investigated analytes comprised NO, acetaldehyde, butadiene, acrolein, propanal, acetone, isoprene, furan, crotonaldehyde, isobutanal, butanal, 2-butanone, benzene, and toluene. The determined amounts of these compounds in cigarette smoke agreed excellently with the literature values. Furthermore, the two well-known patterns of puff-by-puff behaviors for these different smoke constituents were obtained for both whole smoke and gas-phase measurements.

3.
Anal Chem ; 83(10): 3865-72, 2011 May 15.
Article in English | MEDLINE | ID: mdl-21500772

ABSTRACT

This work describes the realization of rapid switching between hard electron ionization (EI) and soft single-photon ionization (SPI) integrated in a compact orthogonal acceleration time-of-flight mass spectrometer. Vacuum-ultraviolet (VUV) photons of 9.8 eV (126 nm) emitted from the innovative electron-beam-pumped rare-gas excimer light source (EBEL) filled with argon are focused into the ion chamber by an ellipsoidal mirror optic for accomplishing of SPI. This novel orthogonal acceleration time-of-flight mass spectrometer with switching capability was hyphenated to one-dimensional gas chromatography (GC) and comprehensive two-dimensional (2D) gas chromatography (GC × GC) for the first time. Within this demonstration study, a maximum switching frequency of 80 Hz was applied for investigation of a mineral-oil-type diesel sample. This approach allows the quasi-simultaneous acquisition of complementary information about the fragmentation pattern (EI) as well as the molecular mass (SPI) of compounds within a single analysis. Furthermore, by application of a polar GC column for separation, the SPI data can be displayed in a 2D contour plot, leading to a comprehensive 2D characterization (GC × MS), whereas the typical group-type assignment for diesel is also met.


Subject(s)
Gas Chromatography-Mass Spectrometry/methods , Gasoline/analysis , Argon/chemistry , Gas Chromatography-Mass Spectrometry/instrumentation , Photons
4.
Anal Bioanal Chem ; 398(3): 1435-45, 2010 Oct.
Article in English | MEDLINE | ID: mdl-20669008

ABSTRACT

One- and comprehensive two-dimensional gas chromatography were hyphenated with soft photoionization mass spectrometry. The characteristics of these two- and three-dimensional comprehensive separation techniques are discussed in detail. Using the innovative electron beam pumped excimer light source (EBEL) for single-photon ionization (SPI), organic molecules with ionization energies (E ( i )) of below 9.8 eV can be detected by a time-of-flight mass spectrometer (TOF-MS). SPI with 126 nm vacuum ultraviolet (VUV) photons enables the universal and soft ionization of organic molecules. SPI-TOF-MS hyphenated to one-dimensional gas chromatography results in a comprehensive two-dimensional separation method (GCxMS). To demonstrate this, diesel fuel was analyzed, and the resulting GCxMS chromatograms are discussed in depth. A three-dimensional separation method was also realized by combining comprehensive two-dimensional gas chromatography (GCxGC) with SPI-MS. In the resulting separation space, constituents originating from mineral oil diesel blended with biodiesel were dispersed along the two GC separation axes, while the molecular mass axis served as a third separation dimension.

SELECTION OF CITATIONS
SEARCH DETAIL
...