Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
J Chromatogr B Biomed Sci Appl ; 740(2): 159-68, 2000 Apr 14.
Article in English | MEDLINE | ID: mdl-10821401

ABSTRACT

Irinotecan (CPT-11) is an anticancer agent widely employed in the treatment of colorectal carcinoma. A simple, rapid and sensitive high-performance liquid chromatographic method for the simultaneous determination of CPT-11 and its metabolite SN-38 in plasma, and their preliminary clinical pharmacokinetics are described. Both deproteinisation of plasma specimens (100 microl) and addition of the internal standard, camptothecin (CPT), are achieved by incorporating to samples 100 microl of a solution of CPT (1 microg/ml) in acetonitrile-1 mM orthophosphoric acid (90:10); 200 microl of this acidified acetonitrile solution, drug-free, is also added to accomplish complete deproteinisation: this procedure reduces sample preparation time to a minimum. After deproteinisation, samples are treated with potassium dihydrogenphosphate (0.1 M) and injected into a Nucleosil C18 (5 microm, 250 x 4.0 mm) column. Mobile phase consists of potassium dihydrogenphosphate (0.1 M)-acetonitrile (67:33), at a flow-rate of 1 ml/min. CPT-11, SN-38 and CPT are detected by fluorescence with excitation wavelength set at 228 nm and emission wavelengths of CPT-11, SN-38 and CPT fixed, respectively, at 450, 543 and 433 nm. The limits of quantitation for CPT-11 and SN-38 are 1.0 and 0.5 ng/ml, respectively. This method shows good precision: the within day relative standard deviation (RSD) for CPT-11 (1-10000 ng/ml) is 5.17% (range 2.15-8.27%) and for SN-38 (0.5-400 ng/ml) is 4.33% (1.32-7.78%); the between-day RSDs for CPT-11 and SN-38, in the previously described ranges, are 6.82% (5.03-10.8%) and 4.94% (2.09-9.30%), respectively. Using this assay, plasma pharmacokinetics of CPT-11, SN-38 and its glucuronidated form, SN-38G, have been determined in one patient receiving 200 mg/m2 of CPT-11 as a 90 min intravenous infusion. The peak plasma concentration of CPT-11 at the end of the infusion is 3800 ng/ml. Plasma decay is biphasic with a terminal half-life of 11.6 h. The volume of distribution at steady state (Vss) is 203 l/m2, and the total body clearance (Cl) is 14.8 l/h x m2. The maximum concentrations of SN-38 and SN-38G reach 28.9 and 151 ng/ml, respectively.


Subject(s)
Camptothecin/analogs & derivatives , Enzyme Inhibitors/blood , Enzyme Inhibitors/pharmacokinetics , Topoisomerase I Inhibitors , Area Under Curve , Camptothecin/administration & dosage , Camptothecin/blood , Camptothecin/pharmacokinetics , Chromatography, High Pressure Liquid , Enzyme Inhibitors/administration & dosage , Half-Life , Humans , Indicators and Reagents , Infusions, Intravenous , Irinotecan , Reproducibility of Results , Spectrometry, Fluorescence
2.
J Chromatogr B Biomed Sci Appl ; 736(1-2): 97-102, 1999 Dec 24.
Article in English | MEDLINE | ID: mdl-10676988

ABSTRACT

5-Fluorouracil (5-FU) is an antineoplastic agent widely employed in the treatment of many types of cancer. Recent studies have proved the need for individual adjustment of 5-FU dosage based on pharmacokinetics. A simple and sensitive high-performance liquid chromatographic method for the determination of 5-FU in plasma and their preliminary clinical pharmacokinetics is described. After sample acidification with 20 microl of orthophosphoric acid (5%), the drug is extracted from plasma using n-propanol-diethyl ether (16:84). The organic layer is evaporated to dryness, the residue dissolved in 100 microl of mobile phase and 20 microl of this mixture is injected into a LiChrospher 100RP-18 (5 microm, 250 x 4.0 mm) analytical column. Mobile phase consisted of potassium dihydrogenphosphate (0.05 M, adjusted to pH 3). The limit of quantitation was 2 ng/ml. The method showed good precision: the within-day relative standard deviation (RSD) for 5-FU (10-20,000 ng/ml) was 3.75% (2.57-5.93); the between-day RSD for 5-FU, in the previously described range, was 5.74% (4.35-7.20). The method presented here is accurate, precise and sensitive and it has been successfully applied for 5-FU pharmacokinetic investigation and therapeutic drug monitoring.


Subject(s)
Chromatography, High Pressure Liquid/methods , Fluorouracil/blood , Fluorouracil/pharmacokinetics , Chemical Precipitation , Drug Monitoring , Fluorouracil/administration & dosage , Humans , Hydrogen-Ion Concentration , Quality Control , Sensitivity and Specificity , Solvents
SELECTION OF CITATIONS
SEARCH DETAIL
...