1.
Am J Hematol ; 96(10): 1264-1274, 2021 10 01.
Article in English | MEDLINE | ID: mdl-34264525

ABSTRACT

Hematology analyzers capable of performing complete blood count (CBC) have lagged in their prevalence at the point-of-care. Sight OLO (Sight Diagnostics, Israel) is a novel hematological platform which provides a 19-parameter, five-part differential CBC, and is designed to address the limitations in current point-of-care hematology analyzers using recent advances in artificial intelligence (AI) and computer vision. Accuracy, repeatability, and flagging capabilities of OLO were compared with the Sysmex XN-Series System (Sysmex, Japan). Matrix studies compared performance using venous, capillary and direct-from-fingerprick blood samples. Regression analysis shows strong concordance between OLO and the Sysmex XN, demonstrating that OLO performs with high accuracy for all CBC parameters. High repeatability and reproducibility were demonstrated for most of the testing parameters. The analytical performance of the OLO hematology analyzer was validated in a multicenter clinical laboratory setting, demonstrating its accuracy and comparability to clinical laboratory-based hematology analyzers. Furthermore, the study demonstrated the validity of CBC analysis of samples collected directly from fingerpricks.


Subject(s)
Artificial Intelligence , Blood Cell Count/instrumentation , Point-of-Care Systems , Blood Cell Count/methods , Equipment Design , Humans , Reproducibility of Results
2.
J Clin Microbiol ; 55(3): 768-775, 2017 03.
Article in English | MEDLINE | ID: mdl-27974542

ABSTRACT

The World Health Organization estimates that nearly 500 million malaria tests are performed annually. While microscopy and rapid diagnostic tests (RDTs) are the main diagnostic approaches, no single method is inexpensive, rapid, and highly accurate. Two recent studies from our group have demonstrated a prototype computer vision platform that meets those needs. Here we present the results from two clinical studies on the commercially available version of this technology, the Sight Diagnostics Parasight platform, which provides malaria diagnosis, species identification, and parasite quantification. We conducted a multisite trial in Chennai, India (Apollo Hospital [n = 205]), and Nairobi, Kenya (Aga Khan University Hospital [n = 263]), in which we compared the device to microscopy, RDTs, and PCR. For identification of malaria, the device performed similarly well in both contexts (sensitivity of 99% and specificity of 100% at the Indian site and sensitivity of 99.3% and specificity of 98.9% at the Kenyan site, compared to PCR). For species identification, the device correctly identified 100% of samples with Plasmodium vivax and 100% of samples with Plasmodium falciparum in India and 100% of samples with P. vivax and 96.1% of samples with P. falciparum in Kenya, compared to PCR. Lastly, comparisons of the device parasite counts with those of trained microscopists produced average Pearson correlation coefficients of 0.84 at the Indian site and 0.85 at the Kenyan site.


Subject(s)
Diagnostic Tests, Routine/methods , Malaria, Falciparum/diagnosis , Malaria, Vivax/diagnosis , Plasmodium falciparum/isolation & purification , Plasmodium vivax/isolation & purification , Humans , India , Kenya , Parasite Load/methods , Plasmodium falciparum/classification , Plasmodium vivax/classification , Prospective Studies , Sensitivity and Specificity
3.
Opt Express ; 17(21): 18659-68, 2009 Oct 12.
Article in English | MEDLINE | ID: mdl-20372598

ABSTRACT

We introduce an illumination configuration which is a spatiotemporal analog of a non-diffracting X-wave. By interfering multiple ultrashort converging plane waves, we generate a tight central spot at which a transform limited ultrashort pulse is formed. Outside this tight focus a spatiotemporal speckle field with longer duration and reduced peak power is created. We investigate this spatiotemporal X-wave configuration analytically, numerically, and experimentally demonstrate the effect using two photon excitation fluorescence.