Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters











Database
Language
Publication year range
1.
J Am Heart Assoc ; 12(2): e026469, 2023 01 17.
Article in English | MEDLINE | ID: mdl-36628977

ABSTRACT

Background Atherosclerosis vulnerability regression has been evidenced mostly in randomized clinical trials with intensive lipid-lowering therapy. We aimed to demonstrate vulnerability regression in real life, with a comprehensive quantitative method, in patients with asymptomatic mild to moderate carotid atherosclerosis on a secondary prevention program. Methods and Results We conducted a single-center prospective observational study (MAGNETIC [Magnetic Resonance Imaging as a Gold Standard for Noninvasive Evaluation of Atherosclerotic Involvement of Carotid Arteries]): 260 patients enrolled at a cardiac rehabilitation center were followed for 3 years with serial magnetic resonance imaging. Per section cutoffs (95th/5th percentiles) were derived from a sample of 20 consecutive magnetic resonance imaging scans: (1) lipid-rich necrotic core: 26% of vessel wall area; (2) intraplaque hemorrhage: 12% of vessel wall area; and (3) fibrous cap: (a) minimum thickness: 0.06 mm, (b) mean thickness: 0.4 mm, (c) projection length: 11 mm. Patients with baseline magnetic resonance imaging of adequate quality (n=247) were classified as high (n=63, 26%), intermediate (n=65, 26%), or low risk (n=119, 48%), if vulnerability criteria were fulfilled in ≥2 contiguous sections, in 1 or multiple noncontiguous sections, or in any section, respectively. Among high-risk patients, a conversion to any lower-risk status was found in 11 (17%; P=0.614) at 6 months, in 16 (25%; P=0.197) at 1 year, and in 19 (30%; P=0.009) at 3 years. Among patients showing any degree of carotid plaque vulnerability, 21 (16%; P=0.014) were diagnosed at low risk at 3 years. Conclusions This study demonstrates with a quantitative approach that vulnerability regression is common in real life. A secondary prevention program can promote vulnerability regression in asymptomatic patients in the mid to long term.


Subject(s)
Atherosclerosis , Carotid Artery Diseases , Carotid Stenosis , Plaque, Atherosclerotic , Humans , Prospective Studies , Carotid Stenosis/complications , Carotid Artery Diseases/complications , Magnetic Resonance Imaging/methods , Carotid Arteries/diagnostic imaging , Carotid Arteries/pathology , Plaque, Atherosclerotic/pathology , Atherosclerosis/pathology , Magnetic Resonance Spectroscopy , Lipids
2.
J Cardiovasc Magn Reson ; 20(1): 74, 2018 11 19.
Article in English | MEDLINE | ID: mdl-30454074

ABSTRACT

BACKGROUND: Clinical evaluation of stress perfusion cardiovascular magnetic resonance (CMR) is currently based on visual assessment and has shown high diagnostic accuracy in previous clinical trials, when performed by expert readers or core laboratories. However, these results may not be generalizable to clinical practice, particularly when less experienced readers are concerned. Other factors, such as the level of training, the extent of ischemia, and image quality could affect the diagnostic accuracy. Moreover, the role of rest images has not been clarified. The aim of this study was to assess the diagnostic accuracy of visual assessment for operators with different levels of training and the additional value of rest perfusion imaging, and to compare visual assessment and automated quantitative analysis in the assessment of coronary artery disease (CAD). METHODS: We evaluated 53 patients with known or suspected CAD referred for stress-perfusion CMR. Nine operators (equally divided in 3 levels of competency) blindly reviewed each case twice with a 2-week interval, in a randomised order, with and without rest images. Semi-automated Fermi deconvolution was used for quantitative analysis and estimation of myocardial perfusion reserve as the ratio of stress to rest perfusion estimates. RESULTS: Level-3 operators correctly identified significant CAD in 83.6% of the cases. This percentage dropped to 65.7% for Level-2 operators and to 55.7% for Level-1 operators (p < 0.001). Quantitative analysis correctly identified CAD in 86.3% of the cases and was non-inferior to expert readers (p = 0.56). When rest images were available, a significantly higher level of confidence was reported (p = 0.022), but no significant differences in diagnostic accuracy were measured (p = 0.34). CONCLUSIONS: Our study demonstrates that the level of training is the main determinant of the diagnostic accuracy in the identification of CAD. Level-3 operators performed at levels comparable with the results from clinical trials. Rest images did not significantly improve diagnostic accuracy, but contributed to higher confidence in the results. Automated quantitative analysis performed similarly to level-3 operators. This is of increasing relevance as recent technical advances in image reconstruction and analysis techniques are likely to permit the clinical translation of robust and fully automated quantitative analysis into routine clinical practice.


Subject(s)
Adenosine/administration & dosage , Coronary Artery Disease/diagnostic imaging , Coronary Circulation , Education, Medical, Graduate/methods , Magnetic Resonance Imaging/methods , Myocardial Perfusion Imaging/methods , Observer Variation , Vasodilator Agents/administration & dosage , Visual Perception , Aged , Automation , Certification , Clinical Competence , Coronary Artery Disease/physiopathology , Education, Medical, Graduate/standards , Female , Humans , Image Interpretation, Computer-Assisted , Learning Curve , Male , Middle Aged , Predictive Value of Tests , Reproducibility of Results
3.
J Digit Imaging ; 29(1): 14-21, 2016 Feb.
Article in English | MEDLINE | ID: mdl-26175139

ABSTRACT

The broad availability of cheap three-dimensional (3D) printing equipment has raised the need for a thorough analysis on its effects on clinical accuracy. Our aim is to determine whether the accuracy of 3D printing process is affected by the use of a low-budget workflow based on open source software and consumer's commercially available 3D printers. A group of test objects was scanned with a 64-slice computed tomography (CT) in order to build their 3D copies. CT datasets were elaborated using a software chain based on three free and open source software. Objects were printed out with a commercially available 3D printer. Both the 3D copies and the test objects were measured using a digital professional caliper. Overall, the objects' mean absolute difference between test objects and 3D copies is 0.23 mm and the mean relative difference amounts to 0.55 %. Our results demonstrate that the accuracy of 3D printing process remains high despite the use of a low-budget workflow.


Subject(s)
Printing, Three-Dimensional/standards , Tomography, X-Ray Computed , Equipment Design , Printing, Three-Dimensional/instrumentation , Reproducibility of Results , Software , Workflow
4.
J Radiol Case Rep ; 8(4): 8-15, 2014 Apr.
Article in English | MEDLINE | ID: mdl-24967030

ABSTRACT

Cardiac metastases are rare, but more common than primary cardiac tumours, and metastatic melanoma involves heart or pericardium in greater than 50% of the cases, although cardiac metastasis are rarely diagnosed ante mortem because of the lack of symptoms. A multimodality approach may help to obtain a more timely diagnosis and in some cases a quicker and better diagnosis can enable a surgical resection to prevent cardiac failure or to reduce the tumour before chemotherapy. We present a case of a patient with cardiac metastasis as first evidence of a malignant melanoma: in this case the patient underwent echocardiography, cardiac magnetic resonance and computed tomography. This case underlines the importance of advanced diagnostic techniques, such as cardiac magnetic resonance, not only for the detection of cardiac masses, but also for a better anatomic definition and tissue characterization, to enable a quick and accurate diagnosis which can be followed by appropriate treatment.


Subject(s)
Heart Neoplasms/diagnosis , Heart Neoplasms/secondary , Melanoma/diagnosis , Melanoma/secondary , Skin Neoplasms/pathology , Diagnosis, Differential , Echocardiography , Electrocardiography , Humans , Magnetic Resonance Imaging , Male , Middle Aged , Sacrococcygeal Region/pathology , Tomography, X-Ray Computed
SELECTION OF CITATIONS
SEARCH DETAIL