Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Publication year range
1.
ABC., imagem cardiovasc ; 36(2): e20230027, maio 2023. ilus, tab
Article in English, Portuguese | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1435626

ABSTRACT

INTRODUÇÃO: A avaliação de congestão pulmonar ambulatorial em pacientes com insuficiência cardíaca com fração de ejeção reduzida (ICFER) pode minimizar internações por descompensação e otimizar o uso de diuréticos. OBJETIVO: Comparar o dispositivo dielétrico remoto (DDR), equipamento validado para detectar líquido extravascular pulmonar, com parâmetros clínicos, medidas de ecocardiograma transtorácico (ETT) e ultrassom de pulmão (ULSP). MÉTODOS: Incluímos 38 pacientes do ambulatório de miocardiopatias (63±12 anos; 21 homens). Todos foram submetidos, num período de 24 horas, à avaliação clínica com descrição de dispneia paroxística noturna, edema de membros inferiores (EMI), presença de tonturas; avaliação laboratorial de NT-ProBNP; avaliação pelo DDR e ETT com análise de parâmetros de congestão sistêmica pela veia cava inferior, função do ventrículo direito e de congestão pulmonar, como a avaliação das pressões de enchimento por meio E/e' médio e volume indexado do átrio esquerdo. O ULSP foi realizado com o protocolo de 8 quadrantes anteriores, com contagem de linhas B em um ciclo respiratório. RESULTADOS: 22 pacientes apresentavam DDR ≥ 35% (congestão pulmonar) e 16 pacientes DDR < 35%. Parâmetros clínicos e ecocardiográficos foram comparados com o DDR ≥ 35%. Na análise multivariada, as variáveis superfície corpórea (SC), linhas B e EMI se associaram a DDR ≥ 35%. NT-ProBNP foi semelhante e elevado em ambos os grupos. CONCLUSÕES: O acompanhamento ambulatorial de ICFER para controle volêmico pode ser sensibilizado pela presença de linhas B no ULSP, que apresenta boa correlação com DDR ≥ 35%. NT-ProBNP não foi capaz de diferenciar pacientes com maior grau de congestão detectado pelo DDR.


BACKGOUND: Outpatient assessment of pulmonary congestion in patients with heart failure with reduced ejection fraction (HFREF) can minimize hospitalizations due to decompensation and optimize the use of diuretics. OBJECTIVE: To compare the remote dielectric sensor (REDS), a validated device for detecting pulmonary extravascular fluid, with clinical parameters, transthoracic echocardiogram (TTE) and lung ultrasound (ULSP). METHODS: We included 38 patients from heart failure clinic (63±12 years; 21 men). All were submitted within 24 hours to clinical evaluation with description of paroxysmal nocturnal dyspnea, leg edema (LE), presence of dizziness; laboratory evaluation of NT-ProBNP; evaluation by SDR and TTE with analysis of parameters of systemic congestion by the inferior vena cava evaluation, function of the right ventricle and of pulmonary congestion, such as evaluation of filling pressures by average of E/e' and indexed left atrial volume. The ULSP was performed using the 8 points anterior quadrants protocol, counting B lines in one respiratory cycle. RESULTS: 22 patients had REDS ≥ 35% (indicative of pulmonary congestion) and 16 patients REDS < 35%. Clinical and echocardiographic parameters were compared with REDS ≥ 35%. In the multivariate analysis, the variables body surface area, B lines and LE were associated with REDS ≥ 35%. NT-ProBNP was similar and elevated in both groups. CONCLUSIONS: Outpatient monitoring of HFREF for volume control can be sensitized by the presence of B lines on the ULSP with good correlation to REDS ≥ 35%. NT pro BNP was not able to differentiate patients with congestion detected by REDS.


Subject(s)
Pulmonary Edema , Heart Failure , Ultrasonography , Heart Failure, Systolic
2.
ABC., imagem cardiovasc ; 35(3): ecom22, 2022. ilus, tab
Article in English, Portuguese | CONASS, Sec. Est. Saúde SP, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1411086

Subject(s)
Ultrasonics , Dyspnea , Lung
SELECTION OF CITATIONS
SEARCH DETAIL
...