Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Type of study
Language
Publication year range
1.
J Curr Glaucoma Pract ; 10(3): 85-90, 2016.
Article in English | MEDLINE | ID: mdl-27857487

ABSTRACT

AIM: To determine the relationship between macular thickness (MT) and visual field (VF) parameters, as well as with changes in the retinal nerve fiber layer (RNFL) thickness in patients with glaucoma and ocular hypertension (OH). MATERIALS AND METHODS: Cross-sectional statistical analysis of spectral domain optical coherence tomography (SD-OCT) compared with several VF parameters (mean defect - MD and loss variance - LV), in a nonrandom sample of 70 eyes from patients with glaucoma or OH. Statistical analysis was performed using Statistical Package for Social Sciences®. The correlation coefficient used was determined by Spearman correlation and the value of p < 0.05 was considered statistically significant. RESULTS: A significant correlation was seen between VF parameters and decrease in MT (MD: r = -0.363, p = 0.002; LV: r=-0.378, p = 0.001). The results were more significant when we compared the LV in the group with average MT 270 to 300 µm (r = -0.413, p = 0.015). Asymmetry between the superior macula and inferior macula correlated with LV (r = 0.432, p = 0.019) in the group with MT < 270 µm. There was also a significant correlation between thinning of superior-temporal and inferior-temporal RNFL and the decrease of the superior and inferior MT respectively (p < 0.001). CONCLUSION: Spectral domain optical coherence tomography measurements of retinal thickness in the macula correlate with VF parameters and RNFL parameters in glaucoma patients. This relationship was first demonstrated with static computerized perimetry made with Octopus 101®. These results can be a valuable aid for evaluating and monitoring of glaucoma patients, establishing a correlation between structure and function. Measurements of retinal thickness in the macula may be an additional instrument for early detection of structural changes and its correlation with functional defects. HOW TO CITE THIS ARTICLE: Mota M, Vaz FT, Ramalho M, Pedrosa C, Lisboa M, Kaku P, Esperancinha F. Macular Thickness Assessment in Patients with Glaucoma and Its Correlation with Visual Fields. J Curr Glaucoma Pract 2016;10(3):85-90.

2.
Ophthalmic Surg Lasers Imaging ; 38(3): 233-7, 2007.
Article in English | MEDLINE | ID: mdl-17552391

ABSTRACT

The anatomic response to intravitreal bevacizumab injection in three patients with aggressive, posterior retinopathy of prematurity is described. In all cases, the worse eye was treated with a single intravitreal injection of 0.75 mg of bevacizumab as monotherapy or complementary to laser therapy. In 24 hours, all injected eyes showed regression of the tunica vasculosa lentis and iris vessel engorgement and disappearance of iris rigidity. In addition, plus disease and retinal proliferation began to regress. None of the eyes required additional treatment. Follow-up of up to 10 months


Subject(s)
Angiogenesis Inhibitors/therapeutic use , Antibodies, Monoclonal/therapeutic use , Retinopathy of Prematurity/drug therapy , Antibodies, Monoclonal, Humanized , Bevacizumab , Gestational Age , Humans , Infant, Newborn , Infant, Premature , Infant, Very Low Birth Weight , Injections , Treatment Outcome , Vascular Endothelial Growth Factor A/antagonists & inhibitors , Vitreous Body
SELECTION OF CITATIONS
SEARCH DETAIL
...