Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 7 de 7
Filter
Add more filters










Database
Language
Publication year range
1.
J Phys Chem B ; 115(21): 6827-37, 2011 Jun 02.
Article in English | MEDLINE | ID: mdl-21553910

ABSTRACT

Complementary neutron and X-ray small angle scattering results give prominent information on the asphaltene nanostructure. Precise SANS and SAXS measurements on a large q-scale were performed on the same dilute asphaltene-toluene solution, and absolute intensity scaling was carried out. Direct comparison of neutron and X-ray spectra enables description of a fractal organization made from the aggregation of small entities of 16 kDa, exhibiting an internal fine structure. Neutron contrast variation experiments enhance the description of this nanoaggregate in terms of core-shell disk organization, giving insight into core and shell dimensions and chemical compositions. The nanoaggregates are best described by a disk of total radius 32 Å with 30% polydispersity and a height of 6.7 Å. Composition and density calculations show that the core is a dense and aromatic structure, contrary to the shell, which is highly aliphatic. These results show a good agreement with the general view of the Yen model (Yen, T. F.; et al. Anal. Chem.1961, 33, 1587-1594) and as for the modified Yen model (Mullins, O. C. Energy Fuels2010, 24, 2179-2207), provide characteristic dimensions of the asphaltene nanoaggregate in good solvent.

2.
J Chromatogr A ; 1186(1-2): 236-44, 2008 Apr 04.
Article in English | MEDLINE | ID: mdl-18242621

ABSTRACT

In the current energetic context (increasing consumption of vehicle fuels, greenhouse gas emission etc.) government policies lead to mandatory introduction in fossil fuels of fuels resulting from renewable sources of energy such as biomass. Blending of fatty acid alkyl esters from vegetable oils (also known as biodiesel) with conventional diesel fuel is one of the solutions technologically available; B5 blends (up to 5%w/w esters in fossil fuel) are marketed over Europe. Therefore, for quality control as well as for forensic reasons, it is of major importance to monitor the biodiesel origin (i.e. the fatty acid ester distribution) and its content when it is blend with petroleum diesel. This paper reports a comprehensive two-dimensional gas chromatography (GC x GC) method that was developed for the individual quantitation of fatty acid esters in middle distillates matrices. Several first and the second dimension columns have been investigated and their performances to achieve (i) a group type separation of hydrocarbons and (ii) individual identification and quantitation of fatty acid ester blend with diesel are reported and discussed. Finally, comparison of quantitative GC x GC results with reference methods demonstrates the benefits of GC x GC approach which enables fast and reliable individual quantitation of fatty acid esters in one single run. Results show that under developed chromatographic conditions, quantitative group type analysis of hydrocarbons is also possible, meaning that simultaneous quantification of hydrocarbons and fatty acid esters can be achieved in one single run.


Subject(s)
Bioelectric Energy Sources , Chromatography, Gas/methods , Gasoline/analysis , Hydrocarbons/analysis , Esters/isolation & purification , Hydrocarbons/isolation & purification
3.
J Chromatogr A ; 1178(1-2): 171-7, 2008 Jan 18.
Article in English | MEDLINE | ID: mdl-18082171

ABSTRACT

A new column association using comprehensive two-dimensional gas chromatography for the detailed molecular analysis of hydrocarbon mixtures is reported in this paper. In order to compare the impact of two different secondary columns, a novel column combination relying on a GC x 2GC system was used. This system is based on a non-polar first column (PONA) combined with both a permethylated beta-cyclodextrin (beta-Dex 120) stationary phase and a polysilphenylensiloxane (BPX 50) in the second dimension. Compared to BPX 50 stationary phase, the implementation of beta-cyclodextrin columns as the second dimension was found to improve the resolution between paraffins and naphthenes in the naphtha range but not in the middle distillate range. Attempts to improve the results and to understand the interaction mechanism remained unsuccessful. Therefore, the benefits of the beta-Dex 120-column are only demonstrated on heavy naphtha cut for the quantitation of hydrocarbons.


Subject(s)
Alkanes/analysis , Chromatography, Gas/methods , Cyclodextrins , Mass Spectrometry/methods , Alkanes/isolation & purification
4.
J Chromatogr Sci ; 45(10): 643-9, 2007.
Article in English | MEDLINE | ID: mdl-18078571

ABSTRACT

The detailed characterization of middle distillates is essential for a better understanding of reactions involved in refining processes. Owing to a higher resolution power and an enhanced sensitivity, but especially to a group-type ordering in the chromatographic plane, comprehensive two-dimensional gas chromatography (GCxGC) offers unsurpassed characterization possibilities for petroleum samples. However, GCxGC fails to totally discriminate naphthenes from unsaturates occurring in hydrotreated diesel samples. This article aims at promoting the implementation of LC-GCxGC for the quantitative determination of hydrocarbon distribution in middle distillates, including naphthenes. In this configuration, liquid chromatography (LC) enables the separation of hydrocarbons into two fractions (viz., saturated and unsaturated) before the subsequent analysis of each fraction by GCxGC. In this paper, the choice of GCxGC conditions in order to achieve the separation and identification of hydrocarbons by chemical class is discussed; under these conditions, naphthenes are separated according to the number of saturated rings. For the first time, the presence of di-, tri-, and tetra-naphthenes resulting from the hydroconversion of aromatics can clearly be evidenced. A quantitative procedure for the determination of the distribution of hydrocarbons, including the distribution of naphthenes according to the number of saturated rings, is also proposed and discussed in detail. LC-GCxGC is found to provide an unequalled degree of information that will widely contribute to a better understanding of hydroconversion processes.

5.
J Chromatogr A ; 1148(1): 55-64, 2007 Apr 27.
Article in English | MEDLINE | ID: mdl-17379235

ABSTRACT

This paper reports an analytical method for the comprehensive two-dimensional gas chromatography (GC x GC) separation and identification of nitrogen compounds (N-compounds) in middle distillates according to their types (basicity). For the evaluation of the best chromatographic conditions, a non-polar x polar approach was chosen. The impact of the second dimension (stationary phase and column length) on the separation of basic and neutral N-compounds was evaluated by mean of two-dimensional resolution. This study revealed that the implementation of polar secondary column having free electron pairs improves drastically the separation of N-compounds. Indeed, the presence of permanent dipole-permanent dipole interactions between neutral N-compounds and the stationary phase was enlightened. The comparison of two different nitrogen chemiluminescence detectors (NCD) was also evaluated for GC x GC selective monitoring of N-compounds. Owing to higher resolution power and enhanced sensitivity achieved using developed chromatographic and detection conditions, it was possible to identify univocally and to quantitate N-compounds (i) by class of compounds and (ii), within a class, by carbon number. Finally, quantitative comparison of GC x GC-NCD with conventional gas chromatography illustrates the benefits of GC x GC leading to an excellent correlation with results obtained by American Society for Testing Materials (ASTM) methods for the determination of basic/neutral nitrogen ratio in diesel samples.


Subject(s)
Chromatography, Gas/methods , Nitrogen Compounds/analysis , Luminescent Measurements , Mass Spectrometry , Molecular Structure , Nitrogen Compounds/chemistry , Reproducibility of Results
6.
J Chromatogr Sci ; 44(9): 566-73, 2006 Oct.
Article in English | MEDLINE | ID: mdl-17059685

ABSTRACT

The monitoring of total sulfur content and speciation of individual sulfur-containing compounds in middle distillates is required for efficient catalyst selection and for a better understanding of the kinetics of the reactions involved in hydrotreament processes. Owing to higher resolution power and enhanced sensitivity, comprehensive two-dimensional gas chromatography (GCxGC) hyphenated to sulfur chemiluminescence detection (SCD) has recently evolved as a powerful tool for improving characterization and identification of sulfur compounds. The aim of this paper is to compare quantitatively GCxGC-SCD and various other methods commonly employed in the petroleum industry, such as X-ray fluorescence, conventional GC-SCD, and high-resolution mass spectrometry, for total sulfur content determination and speciation analysis. Different samples of middle distillates have been analyzed to demonstrate the high potential and important advantages of GCxGC-SCD for innovative and quantitative analysis of sulfur-containing compounds. More accurate and detailed results for benzothiophenes and dibenzothiophenes are presented, showing that GCxGC-SCD should become, in the future, an essential tool for sulfur speciation analysis.

7.
J Chromatogr A ; 1090(1-2): 116-25, 2005 Oct 07.
Article in English | MEDLINE | ID: mdl-16196140

ABSTRACT

A multidimensional method providing the composition of a heavy naphtha in paraffins, isoparaffins, olefins, naphthenes, and aromatics (PIONA) in the C8-C14 range is presented. The analytical set-up consists in a silver modified silica olefin trap on-line coupled to comprehensive two-dimensional gas chromatography (GC x GC). In this configuration, hydrocarbons are separated, in gaseous state, in two fractions, saturate and unsaturate, each fraction being subsequently analysed by GC or by GC x GC. The resolution between saturates and olefins was found to be improved compared to a single GC x GC run. The characterisation of the olefin trap highlights the benefits and the limits related to the use of that stationary phase as a double bond selective fractionation medium.


Subject(s)
Alkanes/analysis , Alkenes/chemistry , Chromatography, Gas/methods , Petroleum/analysis , Online Systems , Thermodynamics
SELECTION OF CITATIONS
SEARCH DETAIL
...