Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
ESC Heart Fail ; 9(1): 740-750, 2022 02.
Article in English | MEDLINE | ID: mdl-34734471

ABSTRACT

AIMS: Cardiac resynchronization therapy (CRT) is highly effective in dilated cardiomyopathy (DCM) patients with impaired left ventricular ejection fraction (LVEF) and left bundle block branch. In cardiac amyloidosis (CA) patients, left ventricular dysfunction and conduction defects are common, but the potential of CRT to improve cardiac remodelling and survival in this particular setting remains undefined. We investigated cardiovascular outcomes in CA patients after CRT implantation in terms of CRT echocardiographic response and major cardiovascular events (MACEs). METHODS AND RESULTS: Our retrospective study included 47 CA patients implanted with CRT devices from January 2012 to February 2020, in nine French university hospitals (77 ± 6 years old, baseline LVEF 30 ± 8%) compared with propensity-matched (1:1 for age, LVEF at implantation, and CRT indication) DCM patients with a CRT device. CA patients had lower rates of CRT response (absolute delta LVEF ≥ 10%) compared with DCM patients (36% vs. 70%, P = 0.002). After multivariate Cox analysis, CA was independently associated with MACE (hospitalization for heart failure/cardiovascular death) [hazard ratio (HR) 3.73, 95% confidence interval (CI) 1.85-7.54, P < 0.001], along with the absence of CRT response (HR 3.01, 95% CI 1.56-5.79, P = 0.001). The presence of echocardiographic CRT response (absolute delta LVEF ≥ 10%) was the only predictive factor of MACE-free survival in CA patients (HR 0.36, 95% CI 0.15-0.86, P = 0.002). CONCLUSION: Compared with a matched cohort of DCM patients, CA patients had a lower rate of CRT response and consequently a worse cardiovascular prognosis after CRT implantation. However, CRT could be beneficial even in CA patients given that CRT response was associated with better cardiac outcomes in this population.


Subject(s)
Amyloidosis , Cardiac Resynchronization Therapy , Defibrillators, Implantable , Aged , Aged, 80 and over , Amyloidosis/complications , Amyloidosis/diagnosis , Amyloidosis/therapy , Cardiac Resynchronization Therapy/methods , Humans , Retrospective Studies , Stroke Volume/physiology , Treatment Outcome , Ventricular Function, Left/physiology
2.
Int J Cardiol Heart Vasc ; 29: 100555, 2020 Aug.
Article in English | MEDLINE | ID: mdl-32551360

ABSTRACT

AIMS: This study aimed to determine the impact of the volume of epicardial fat on the duration of radiofrequency (RF) energy delivery during the procedure of ablation of atrial fibrillation (AF). METHODS: The volume of epicardial fat was measured from spiral computerized tomography scan. The primary endpoint was the duration of RF delivery for pulmonary vein isolation (PVI), and the overall total duration of RF application. Secondary endpoint was conversion of AF to sinus rhythm or organisation of the arrhythmia after PVI. RESULTS: From March 2015 to May 2018, 222 patients (45.5% with persistent AF) underwent a first RF catheter ablation procedure for AF. The total duration of RF delivery, and the duration of RF delivery specifically for PVI were significantly associated with higher total volume of epicardial fat (p = 0.0002; p = 0.009 respectively), periatrial (p = 0.003; p = 0.045) and periventricular epicardial fat (p = 0.001; p = 0.012). In multivariate analysis, total epicardial fat volume was not significantly associated with total RF delivery duration (p = 0.743). For patients with arrhythmia at the time of the procedure, patients who achieved conversion or organisation of their arrhythmia after PVI had similar levels of total epicardial fat to those whose arrhythmia persisted (65 ± 35.2 vs 74.5 ± 31.2 ml; p = 0.192). CONCLUSION: We observed a significant relation between total, periatrial, and periventricular epicardial fat, and the duration of RF delivery during ablation of AF. This relation was not significant by multivariate analysis meaning that epicardial fat may be a marker, but not an independent factor, of ablation complexity.

3.
J Clin Med ; 9(3)2020 Mar 20.
Article in English | MEDLINE | ID: mdl-32244983

ABSTRACT

Acute myocarditis is associated with cardiac arrhythmia in 25% of cases; a third of these arrhythmias are ventricular tachycardia (VT) or ventricular fibrillation (VF). The implantation of a cardiac defibrillator (ICD) following sustained ventricular arrhythmia remains controversial in these patients. We sought to assess the risk of major arrhythmic ventricular events (MAEs) over time in patients implanted with an ICD following sustained VT/VF in the acute phase of myocarditis compared to those implanted for VT/VF occurring on myocarditis sequelae. Our retrospective observational study included patients implanted with an ICD following VT/VF during acute myocarditis or VT/VF on myocarditis sequelae, from 2007 to 2017, in 15 French university hospitals. Over a median follow-up period of 3 years, MAE occurred in 11 (39%) patients of the acute myocarditis group and 24 (60%) patients of the myocarditis sequelae group. Kaplan-Meier MAE rate estimates at one and three years of follow-up were 19% and 45% in the acute group, and 43% and 64% in the sequelae group. Patients who experienced sustained ventricular arrhythmias during acute myocarditis had a very high risk of VT/VF recurrence during follow-up. These results show that the risk of MAE recurrence remains high after resolution of the acute episode.

4.
J Interv Card Electrophysiol ; 55(2): 233-237, 2019 Aug.
Article in English | MEDLINE | ID: mdl-31177353

ABSTRACT

PURPOSE: Cardiologists are among the health professionals that are most exposed to ionizing radiation, but there is no study comparing the level of exposure of physicians during different electrophysiology procedures. We aimed to measure and compare cardiologists' exposure to radiation during different electrophysiology procedures. METHODS: The study population comprised all electrophysiology procedures performed over a 6-month period in a large referral centre. The endpoint was operator radiation exposure, assessed using a personal electronic dosimeter located on the operator's left arm. RESULTS: In total, 150 electrophysiology procedures were analyzed. Compared with electrophysiology studies (reference category), physician radiation exposure was 3-fold greater during ablation of atrial fibrillation, 9-fold greater during ablation of atrioventricular nodal reentrant tachycardia (AVNRT)/atrioventricular reentrant tachycardia (AVNT), and 10-fold greater during ablation of atrial flutter (p < 0.001). Physician exposure was mainly related to X-ray time (R2 = 0.28). CONCLUSIONS: Our study showed significant differences in cardiologists' exposure to ionizing radiation depending on the type of electrophysiology procedure. Atrial flutter and AVNRT/AVNT ablations are the procedures in which operators are most exposed to ionizing radiation.


Subject(s)
Cardiologists , Electrophysiologic Techniques, Cardiac , Occupational Exposure , Radiation Exposure , France , Humans , Radiometry , Risk Factors
5.
J Radiol Prot ; 39(2): 489-497, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30913548

ABSTRACT

Cardiologists are among the health professionals that are most exposed to ionizing radiation, but there is no recent study quantifying overexposure of physicians during cardiac resynchronisation therapy (CRT) procedures compared to 'classical' implantation of pacemakers (PMs) or implantable cardioverter-defibrillators (ICDs). We aimed to measure and compare operator exposure to radiation during implantation of PM and ICD with or without CRT. The study population comprised all PMs and ICDs implanted in a large referral centre over a six months period. The endpoint was operator radiation exposure, assessed using a personal electronic dosimeter located on operator's chest. In total, 169 PM/ICD implantations were analysed, 19 of which included CRT. Compared with 'classical' implantation, cardiologist radiation exposure was 9-fold greater during CRT procedures (p < 0.001). Physician exposure was related to dose-area product (R2 = 0.21 during 'classical' implantations and R2 = 0.57 during CRT procedures). Our study shows that cardiologists' exposure to radiation during CRT implantation was 9-fold greater than during procedures without CRT.


Subject(s)
Cardiac Resynchronization Therapy , Cardiology , Defibrillators, Implantable , Occupational Exposure/analysis , Pacemaker, Artificial , Prosthesis Implantation , Radiation Exposure/analysis , Aged , Aged, 80 and over , Cardiac Resynchronization Therapy/adverse effects , Epidemiologic Studies , Female , Humans , Male , Middle Aged , Prospective Studies , Prosthesis Implantation/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...