Biomed Phys Eng Express ; 9(6)2023 10 26.
Article in English | MEDLINE | ID: mdl-37812911

ABSTRACT

Objective.Proton Radiography can be used in conjunction with proton therapy for patient positioning, real-time estimates of stopping power, and adaptive therapy in regions with motion. The modeling capability shown here can be used to evaluate lens-based radiography as an instantaneous proton-based radiographic technique. The utilization of user-friendly Monte Carlo program TOPAS enables collaborators and other users to easily conduct medical- and therapy- based simulations of the Los Alamos Neutron Science Center (LANSCE). The resulting transport model is an open-source Monte Carlo package for simulations of proton and heavy ion therapy treatments and concurrent particle imaging.Approach.The four-quadrupole, magnetic lens system of the 800-MeV proton beamline at LANSCE is modeled in TOPAS. Several imaging and contrast objects were modelled to assess transmission at energies from 230-930 MeV and different levels of particle collimation. At different proton energies, the strength of the magnetic field was scaled according toßγ,the inverse product of particle relativistic velocity and particle momentum.Main results.Materials with high atomic number, Z, (gold, gallium, bone-equivalent) generated more contrast than materials with low-Z (water, lung-equivalent, adipose-equivalent). A 5-mrad collimator was beneficial for tissue-to-contrast agent contrast, while a 10-mrad collimator was best to distinguish between different high-Z materials. Assessment with a step-wedge phantom showed water-equivalent path length did not scale directly according to predicted values but could be mapped more accurately with calibration. Poor image quality was observed at low energies (230 MeV), but improved as proton energy increased, with sub-mm resolution at 630 MeV.Significance.Proton radiography becomes viable for shallow bone structures at 330 MeV, and for deeper structures at 630 MeV. Visibility improves with use of high-Z contrast agents. This modality may be particularly viable at carbon therapy centers with accelerators capable of delivering high energy protons and could be performed with carbon therapy.


Subject(s)
Proton Therapy , Protons , Humans , Radiography , Proton Therapy/methods , Carbon , Water
2.
Sci Rep ; 13(1): 14424, 2023 09 02.
Article in English | MEDLINE | ID: mdl-37660169

ABSTRACT

Rhizosphere microbes, such as root-associated fungi, can improve plant access to soil resources, affecting plant health, productivity, and stress tolerance. While mycorrhizal associations are ubiquitous, plant-microbe interactions can be species specific. Here we show that the specificity of the effects of microbial symbionts on plant function can go beyond species level: colonization of roots by ectomycorrhizal fungi (EMF) of the genus Geopora has opposite effects on water uptake, and stomatal control of desiccation in drought tolerant and intolerant genotypes of pinyon pine (Pinus edulis Engelm.). These results demonstrate, for the first time, that microorganisms can have significant and opposite effects on important plant functional traits like stomatal control of desiccation that are associated with differential mortality and growth in nature. They also highlight that appropriate pairing of plant genotypes and microbial associates will be important for mitigating climate change impacts on vegetation.


Subject(s)
Mycorrhizae , Pinus , Mycorrhizae/genetics , Genotype , Phenotype , Biological Transport
4.
Anal Chem ; 93(46): 15349-15357, 2021 Nov 23.
Article in English | MEDLINE | ID: mdl-34747610

ABSTRACT

The inherently quantitative nature of nuclear magnetic resonance (NMR) spectroscopy is one of the most attractive aspects of this analytical technique. Quantitative NMR analyses have typically been limited to high-field (>1 T) applications. The aspects for quantitation at low magnetic fields (<1 mT) have not been thoroughly investigated and are shown to be impacted by the complex signatures that arise at these fields from strong heteronuclear J-couplings. This study investigates quantitation at Earth's magnetic field (∼50 µT) for a variety of samples in strongly, weakly, and uncoupled spin systems. To achieve accurate results in this regime, the instrumentation, experimental acquisition, processing, and theoretical aspects must be considered and reconciled. Of particular note is the constant field nuclear receptivity equation, which has been re-derived in this study to account for strong coupling and quality factor effects. The results demonstrate that the quantitation of homonuclear molecular groups, determination of heteronuclear pseudoempirical formulas, and mixture analysis are all feasible at Earth's magnetic field in a greatly simplified experimental system.

5.
J Med Imaging (Bellingham) ; 8(5): 053501, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34708145

ABSTRACT

Purpose: Proton radiography may guide proton therapy cancer treatments with beam's-eye-view anatomical images and a proton-based estimation of proton stopping power. However, without contrast enhancement, proton radiography will not be able to distinguish tumor from tissue. To provide this contrast, functionalized, high- Z nanoparticles that specifically target a tumor could be injected into a patient before imaging. We conducted this study to understand the ability of gold, as a high- Z , biologically compatible tracer, to differentiate tumors from surrounding tissue. Approach: Acrylic and gold phantoms simulate a tumor tagged with gold nanoparticles (AuNPs). Calculations correlate a given thickness of gold to levels of tumor AuNP uptake reported in the literature. An identity, × 3 , and × 7 proton magnifying lens acquired lens-refocused proton radiographs at the 800-MeV LANSCE proton beam. The effects of gold in the phantoms, in terms of percent density change, were observed as changes in measured transmission. Variable areal densities of acrylic modeled the thickness of the human body. Results: A 1 - µ m -thick gold strip was discernible within 1 cm of acrylic, an areal density change of 0.2%. Behind 20 cm of acrylic, a 40 - µ m gold strip was visible. A 1-cm-diameter tumor tagged with 1 × 10 5 50-nm AuNPs per cell has an amount of contrast agent embedded within it that is equivalent to a 65 - µ m thickness of gold, an areal density change of 0.63% in a tissue thickness of 20 cm, which is expected to be visible in a typical proton radiograph. Conclusions: We indicate that AuNP-enhanced proton radiography might be a feasible technology to provide image-guidance to proton therapy, potentially reducing off-target effects and sparing nearby tissue. These data can be used to develop treatment plans and clinical applications can be derived from the simulations.

6.
Solid State Nucl Magn Reson ; 110: 101697, 2020 12.
Article in English | MEDLINE | ID: mdl-33075622

ABSTRACT

We report the 1H T1 dispersion curve between 0 and 5 â€‹MHz for the synthetic opioid fentanyl citrate (C28H36N2O8). The structures in the curve can be used to estimate the 14N nuclear quadrupole resonance (NQR) frequencies of the material. Density functional theory predictions of the NQR parameters of several fentanyl citrate compounds are also reported. The predictions for the aniline nitrogen are consistent with structures in the observed T1 data. To help interpret the fentanyl citrate results the T1 dispersion curve for the explosive ammonium nitrate is also presented.

7.
Rev Sci Instrum ; 91(5): 054103, 2020 May 01.
Article in English | MEDLINE | ID: mdl-32486714

ABSTRACT

In recent years, it has been realized that low and ultra-low field (mT-nT magnetic field range) nuclear magnetic resonance spectroscopy can be used for molecular structural analysis. However, spectra are often hindered by lengthy acquisition times or require large sample volumes and high concentrations. Here, we report a low field (50 µT) instrument that employs a linear actuator to shuttle samples between a 1 T prepolarization field and a solenoid detector in a laboratory setting. The current experimental setup is benchmarked using water and 13C-methanol with a single scan detection limit of 2 × 1020 spins (3 µl, 55M H2O) and detection limit of 2.9 × 1019 (200 µl, 617 mM 13C-methanol) spins with signal averaging. The system has a dynamic range of >3 orders of magnitude. Investigations of room-temperature relaxation dynamics of 13C-methanol show that sample dilution can be used in lieu of sample heating to acquire spectra with linewidths comparable to high-temperature spectra. These results indicate that the T1 and T2 mechanisms are governed by both the proton exchange rate and the dissolved oxygen in the sample. Finally, a 2D correlation spectroscopy experiment is reported, performed in the strong coupling regime that resolves the multiple resonances associated with the heteronuclear J-coupling. The spectrum was collected using 10 times less sample and in less than half the time from previous reports in the strong coupling limit.

8.
Anal Chem ; 92(10): 6918-6924, 2020 05 19.
Article in English | MEDLINE | ID: mdl-32338873

ABSTRACT

A new method for measurement of elemental analysis by nuclear magnetic resonance (NMR) of unknown samples is discussed here as a quick and robust means to measure elemental ratios without the use of internal or external calibration standards. The determination of elemental ratios was done by normalizing the signal intensities by the frequency dependent quality factor (Q) and the gyromagnetic ratios (γ) for each measured nucleus. The correction for the frequency dependence was found by characterizing the output signal of the probe as a function of the quality factor (Q) and the frequency, and the correction for γ was discussed in a previous study. A Carr-Purcell-Meiboom-Gill (CPMG) pulse sequence was used for evaluation of the relative signal intensities, which allows for derivation of elemental ratios, and was correspondingly used to simultaneously measure the T2* of samples for an added parameter for more accurate identification of unknown samples.

9.
Anat Rec (Hoboken) ; 303(4): 1043-1059, 2020 04.
Article in English | MEDLINE | ID: mdl-31967416

ABSTRACT

Tyrannosaurus rex and other tyrannosaurid dinosaurs were apex predators during the latest Cretaceous, which combined giant size and advanced neurosensory systems. Computed tomography (CT) data have shown that tyrannosaurids had a trademark system of a large brain, large olfactory bulbs, elongate cochlear ducts, and expansive endocranial sinuses surrounding the brain and sense organs. Older, smaller tyrannosauroid relatives of tyrannosaurids developed some, but not all, of these features, raising the hypothesis that tyrannosaurid-style brains evolved before the enlarged tyrannosaurid-style sinuses, which might have developed only with large body size. This has been difficult to test, however, because little is known about the brains and sinuses of the first large-bodied tyrannosauroids, which evolved prior to Tyrannosauridae. We here present the first CT data for one of these species, Bistahieversor sealeyi from New Mexico. Bistahieversor had a nearly identical brain and sinus system as tyrannosaurids like Tyrannosaurus, including a large brain, large olfactory bulbs, reduced cerebral hemispheres, and optic lobes, a small tab-like flocculus, long and straight cochlear ducts, and voluminous sinuses that include a supraocciptal recess, subcondyar sinus, and an anterior tympanic recess that exits the braincase via a prootic fossa. When characters are plotted onto tyrannosauroid phylogeny, there is a two-stage sequence in which features of the tyrannosaurid-style brain evolved first (in smaller, nontyrannosaurid species like Timurlengia), followed by features of the tyrannosaurid-style sinuses (in the first large-bodied nontyrannosaurid tyrannosauroids like Bistahieversor). This suggests that the signature tyrannosaurid sinus system evolved in concert with large size, whereas the brain did not. Anat Rec, 303:1043-1059, 2020. © 2020 American Association for Anatomy.


Subject(s)
Biological Evolution , Body Size , Dinosaurs/anatomy & histology , Skull/anatomy & histology , Animals , Fossils , Phylogeny , Skull/diagnostic imaging
10.
J Imaging ; 6(5)2020 May 19.
Article in English | MEDLINE | ID: mdl-34460737

ABSTRACT

As work continues in neutron computed tomography, at Los Alamos Neutron Science Center (LANSCE) and other locations, source reliability over the long imaging times is an issue of increasing importance. Moreover, given the time commitment involved in a single neutron image, it is impractical to simply discard a scan and restart in the event of beam instability. In order to mitigate the cost and time associated with these options, strategies are presented in the current work to produce a successful reconstruction of computed tomography data from an unstable source. The present work uses a high energy neutron tomography dataset from a simulated munition collected at LANSCE to demonstrate the method, which is general enough to be of use in conjunction with unstable X-ray computed tomography sources as well.

11.
Phys Plasmas ; 24(5): 056702, 2017 May.
Article in English | MEDLINE | ID: mdl-28652684

ABSTRACT

Laser-plasma interactions in the novel regime of relativistically induced transparency (RIT) have been harnessed to generate intense ion beams efficiently with average energies exceeding 10 MeV/nucleon (>100 MeV for protons) at "table-top" scales in experiments at the LANL Trident Laser. By further optimization of the laser and target, the RIT regime has been extended into a self-organized plasma mode. This mode yields an ion beam with much narrower energy spread while maintaining high ion energy and conversion efficiency. This mode involves self-generation of persistent high magnetic fields (∼104 T, according to particle-in-cell simulations of the experiments) at the rear-side of the plasma. These magnetic fields trap the laser-heated multi-MeV electrons, which generate a high localized electrostatic field (∼0.1 T V/m). After the laser exits the plasma, this electric field acts on a highly structured ion-beam distribution in phase space to reduce the energy spread, thus separating acceleration and energy-spread reduction. Thus, ion beams with narrow energy peaks at up to 18 MeV/nucleon are generated reproducibly with high efficiency (≈5%). The experimental demonstration has been done with 0.12 PW, high-contrast, 0.6 ps Gaussian 1.053 µm laser pulses irradiating planar foils up to 250 nm thick at 2-8 × 1020 W/cm2. These ion beams with co-propagating electrons have been used on Trident for uniform volumetric isochoric heating to generate and study warm-dense matter at high densities. These beam plasmas have been directed also at a thick Ta disk to generate a directed, intense point-like Bremsstrahlung source of photons peaked at ∼2 MeV and used it for point projection radiography of thick high density objects. In addition, prior work on the intense neutron beam driven by an intense deuterium beam generated in the RIT regime has been extended. Neutron spectral control by means of a flexible converter-disk design has been demonstrated, and the neutron beam has been used for point-projection imaging of thick objects. The plans and prospects for further improvements and applications are also discussed.

12.
J Magn Reson ; 272: 181, 2016 11.
Article in English | MEDLINE | ID: mdl-27756461
13.
Front Plant Sci ; 7: 564, 2016.
Article in English | MEDLINE | ID: mdl-27200037

ABSTRACT

Using a simple low-field NMR system, we monitored water content in a living tree in a greenhouse over 2 months. By continuously running the system, we observed changes in tree water content on a scale of half an hour. The data showed a diurnal change in water content consistent both with previous NMR and biological observations. Neutron imaging experiments show that our NMR signal is primarily due to water being rapidly transported through the plant, and not to other sources of hydrogen, such as water in cytoplasm, or water in cell walls. After accounting for the role of temperature in the observed NMR signal, we demonstrate a change in the diurnal signal behavior due to simulated drought conditions for the tree. These results illustrate the utility of our system to perform noninvasive measurements of tree water content outside of a temperature controlled environment.

14.
Rev Sci Instrum ; 85(9): 095110, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25273775

ABSTRACT

Nuclear magnetic resonance (NMR) and magnetic resonance imaging have long been used to study water content in plants. Approaches have been primarily based on systems using large magnetic fields (~1 T) to obtain NMR signals with good signal-to-noise. This is because the NMR signal scales approximately with the magnetic field strength squared. However, there are also limits to this approach in terms of realistic physiological configuration or those imposed by the size and cost of the magnet. Here we have taken a different approach--keeping the magnetic field low to produce a very light and inexpensive system, suitable for bulk water measurements on trees less than 5 cm in diameter, which could easily be duplicated to measure on many trees or from multiple parts of the same tree. Using this system we have shown sensitivity to water content in trees and their cuttings and observed a diurnal signal variation in tree water content in a greenhouse. We also demonstrate that, with calibration and modeling of the thermal polarization, the system is reliable under significant temperature variation.


Subject(s)
Magnetic Resonance Spectroscopy/methods , Trees/chemistry , Water/analysis , Water/chemistry , Environment, Controlled , Magnetic Resonance Spectroscopy/instrumentation
15.
J Magn Reson ; 229: 127-41, 2013 Apr.
Article in English | MEDLINE | ID: mdl-23452838

ABSTRACT

MRI remains the premier method for non-invasive imaging of soft-tissue. Since the first demonstration of ULF MRI the trend has been towards ever higher magnetic fields. This is because the signal, and efficiency of Faraday detectors, increases with ever higher magnetic fields and corresponding Larmor frequencies. Nevertheless, there are many compelling reasons to continue to explore MRI at much weaker magnetic fields, the so-called ultra-low field or (ULF) regime. In the past decade many excellent proof-of-concept demonstrations of ULF MRI have been made. These include combined MRI and magnetoencephalography, imaging in the presence of metal, unique tissue contrast, and implementation in situations where a high magnetic field is simply impractical. These demonstrations have routinely used pulsed pre-polarization (at magnetic fields from ~10 to 100 mT) followed by read-out in a much weaker (1-100 µT) magnetic fields using the ultra-sensitive Superconducting Quantum Interference Device (SQUID) sensor. Even with pre-polarization and SQUID detection, ULF MRI suffers from many challenges associated with lower magnetization (i.e. signal) and inherently long acquisition times compared to conventional >1 T MRI. These are fundamental limitations imposed by the low measurement and gradient fields used. In this review article we discuss some of the techniques, potential applications, and inherent challenges of ULF MRI.

16.
J Magn Reson ; 228: 1-15, 2013 Mar.
Article in English | MEDLINE | ID: mdl-23333456

ABSTRACT

MRI remains the premier method for non-invasive imaging of soft-tissue. Since the first demonstration of ULF MRI the trend has been towards ever higher magnetic fields. This is because the signal, and efficiency of Faraday detectors, increases with ever higher magnetic fields and corresponding Larmor frequencies. Nevertheless, there are many compelling reasons to continue to explore MRI at much weaker magnetic fields, the so-called ultra-low field or (ULF) regime. In the past decade many excellent proof-of-concept demonstrations of ULF MRI have been made. These include combined MRI and magnetoencephalography, imaging in the presence of metal, unique tissue contrast, and implementation in situations where a high magnetic field is simply impractical. These demonstrations have routinely used pulsed pre-polarization (at magnetic fields from ∼10 to 100mT) followed by read-out in a much weaker (1-100µT) magnetic fields using the ultra-sensitive Superconducting Quantum Interference Device (SQUID) sensor. Even with pre-polarization and SQUID detection, ULF MRI suffers from many challenges associated with lower magnetization (i.e. signal) and inherently long acquisition times compared to conventional >1T MRI. These are fundamental limitations imposed by the low measurement and gradient fields used. In this review article we discuss some of the techniques, potential applications, and inherent challenges of ULF MRI.


Subject(s)
Brain Mapping/methods , Magnetic Resonance Imaging/methods , Electroencephalography , Equipment Design , Fourier Analysis , Humans , Image Enhancement/methods , Image Processing, Computer-Assisted/methods , Magnetic Resonance Imaging/instrumentation , Magnetoencephalography , Models, Statistical
17.
IEEE Trans Appl Supercond ; 21(3): 465-468, 2011.
Article in English | MEDLINE | ID: mdl-21747638

ABSTRACT

Nuclear magnetic resonance (NMR) is widely used in medicine, chemistry and industry. One application area is magnetic resonance imaging (MRI). Recently it has become possible to perform NMR and MRI in the ultra-low field (ULF) regime requiring measurement field strengths of the order of only 1 Gauss. This technique exploits the advantages offered by superconducting quantum interference devices or SQUIDs. Our group has built SQUID based MRI systems for brain imaging and for liquid explosives detection at airport security checkpoints. The requirement for liquid helium cooling limits potential applications of ULF MRI for liquid identification and security purposes. Our experimental comparative investigation shows that room temperature inductive magnetometers may provide enough sensitivity in the 3-10 kHz range and can be used for fast liquid explosives detection based on ULF NMR technique. We describe experimental and computer-simulation results comparing multichannel SQUID based and induction coils based instruments that are capable of performing ULF MRI for liquid identification.

18.
J Magn Reson ; 207(1): 78-88, 2010 Nov.
Article in English | MEDLINE | ID: mdl-20843715

ABSTRACT

Magnetic resonance imaging at microtesla fields is a promising imaging method that combines the pre-polarization technique and broadband signal reception by superconducting quantum interference device (SQUID) sensors to enable in vivo MRI at microtesla-range magnetic fields similar in strength to the Earth magnetic field. Despite significant advances in recent years, the potential of microtesla MRI for biomedical imaging is limited by its insufficient signal-to-noise ratio due to a relatively low sample polarization. Dynamic nuclear polarization (DNP) is a widely used approach that allows polarization enhancement by 2-4 orders of magnitude without an increase in the polarizing field strength. In this work, the first implementation of microtesla MRI with Overhauser DNP and SQUID signal detection is described. The first measurements of carbon-13 NMR spectra at microtesla fields are also reported. The experiments were performed at the measurement field of 96 µT, corresponding to Larmor frequency of 4 kHz for protons and 1 kHz for carbon-13. The Overhauser DNP was carried out at 3.5-5.7 mT fields using rf irradiation at 120 MHz. Objects for imaging included water phantoms and a cactus plant. Aqueous solutions of metabolically relevant sodium bicarbonate, pyruvate, alanine, and lactate, labeled with carbon-13, were used for NMR studies. All the samples were doped with TEMPO free radicals. The Overhauser DNP enabled nuclear polarization enhancement by factor as large as -95 for protons and as large as -200 for carbon-13, corresponding to thermal polarizations at 0.33 T and 1.1 T fields, respectively. These results demonstrate that SQUID-based microtesla MRI can be naturally combined with Overhauser DNP in one system, and that its signal-to-noise performance is greatly improved in this case. They also suggest that microtesla MRI can become an efficient tool for in vivo imaging of hyperpolarized carbon-13, produced by low-temperature dissolution DNP.


Subject(s)
Magnetic Resonance Imaging/instrumentation , Algorithms , Carbon Radioisotopes/chemistry , Cyclic N-Oxides/chemistry , Electromagnetic Fields , Electron Spin Resonance Spectroscopy , Free Radicals/chemistry , Nitrogen Oxides/chemistry , Signal Processing, Computer-Assisted
19.
IEEE Trans Appl Supercond ; 21(3): 489-492, 2010 Oct 09.
Article in English | MEDLINE | ID: mdl-21747637

ABSTRACT

Progress in the development of high-sensitivity magnetic-field measurements has stimulated interest in understanding the magnetic noise of conductive materials, especially of magnetic shields based on high-permeability materials and/or high-conductivity materials. For example, SQUIDs and atomic magnetometers have been used in many experiments with mu-metal shields, and additionally SQUID systems frequently have radio frequency shielding based on thin conductive materials. Typical existing approaches to modeling noise only work with simple shield and sensor geometries while common experimental setups today consist of multiple sensor systems with complex shield geometries. With complex sensor arrays used in, for example, MEG and Ultra Low Field MRI studies, knowledge of the noise correlation between sensors is as important as knowledge of the noise itself. This is crucial for incorporating efficient noise cancelation schemes for the system. We developed an approach that allows us to calculate the Johnson noise for arbitrary shaped shields and multiple sensor systems. The approach is efficient enough to be able to run on a single PC system and return results on a minute scale. With a multiple sensor system our approach calculates not only the noise for each sensor but also the noise correlation matrix between sensors. Here we will show how the algorithm can be implemented.

20.
J Magn Magn Mater ; 321(10): 1440-1445, 2009 May.
Article in English | MEDLINE | ID: mdl-20161205

ABSTRACT

Our goal is to develop an instrument for parallel and multiplexed bioassay using magnetic labels. Toward this end we are developing a multi-outlet magnetophoresis instrument incorporating a fluidic flow chamber placed inside a magnetic field gradient. Magnetic microparticles are sorted by their magnetic moment for eventual use as biological labels based on magnetic signature.In this paper we concentrate on developments in our flow chamber fabrication methods that have allowed us to scale the number of sorting channels from 8 to 25. We present data for instrument performance and reproducibility of sorting.