1.
Lab Chip ; 12(21): 4232-5, 2012 Nov 07.
Article in English | MEDLINE | ID: mdl-22968667

ABSTRACT

The present paper reports for the first time the integration of a microfluidic system, electronics modules, amperometric sensor and display, all powered by a single micro direct methanol fuel cell. In addition to activating the electronic circuitry, the integrated power source also acts as a tuneable micropump. The electronics fulfil several functions. First, they regulate the micro fuel cell output power, which off-gas controls the flow rate of different solutions toward an electrochemical sensor through microfluidic channels. Secondly, as the fuel cell powers a three-electrode electrochemical cell, the electronics compare the working electrode output signal with a set reference value. Thirdly, if the concentration measured by the sensor exceeds this threshold value, the electronics switch on an integrated organic display. This integrated approach pushes forward the development of truly autonomous point-of-care devices relying on electrochemical detection.


Subject(s)
Electrochemical Techniques/instrumentation , Microfluidic Analytical Techniques/instrumentation , Electrodes , Methanol/chemistry
2.
Biosens Bioelectron ; 26(5): 2426-30, 2011 Jan 15.
Article in English | MEDLINE | ID: mdl-21074397

ABSTRACT

Microbial fuel cells (MFCs) have been used for several years as biosensors for measuring environmental parameters such as biochemical oxygen demand and water toxicity. The present study is focused on the detection of toxic matter using a novel silicon-based MFC. Like other existing toxicity sensors based on MFCs, this device is capable of detecting the variation on the current produced by the cell when toxic compounds are present in the medium. The MFC approach presented in this work aims to obtain a simple, compact and planar device for its further application as a biosensor in the design and fabrication of equipment for toxicity monitoring. It consists on a proton exchange membrane placed between two microfabricated silicon plates that act as current collectors. An array of square 80 µm × 80 µm vertical channels, 300 µm deep, have been defined trough the plates over an area of 6 mm × 6 mm. The final testing assembly incorporates two perspex pieces positioned onto the plates as reservoirs with a working volume of 144 µL per compartment. The operation of the microdevice as a direct electron transfer MFC has been validated by comparing its performance against a larger scale MFC, run under the same conditions. The device has been tested as a toxicity sensor by setting it at a fixed current while monitoring changes in the output power. A drop in the power production is observed when a toxic compound is added to the anode compartment. The compact design of the device makes it suitable for its incorporation into measurement equipment either as an individual device or as an array of sensors for high throughput processing.


Subject(s)
Bioelectric Energy Sources/microbiology , Biological Assay/instrumentation , Biosensing Techniques/instrumentation , Conductometry/instrumentation , Geobacter/drug effects , Toxicity Tests/instrumentation , Equipment Design , Equipment Failure Analysis , Miniaturization , Silicon/chemistry