Arch Bone Jt Surg ; 9(5): 536-542, 2021 Sep.
Article in English | MEDLINE | ID: mdl-34692936

ABSTRACT

BACKGROUND: This study aimed to evaluate the efficacy of hemi-epiphysiodesis using a new device (X-plate) for the correction of genu valgum. METHODS: In total, 22 children with a total of 34 pathologic knee valgus deformities underwent the procedure and were followed up 25.3 months on average. RESULTS: The mean time to clinical correction of genu valgum was 10.9±2.2 months. Furthermore, the mean preoperative anatomic Lateral Distal Femoral Angle (aLDFA) and mechanical Tibia Femoral angle (mTFA) were obtained at 75.1±3.8 and 6±2.8 degrees, respectively. When clinical correction of the deformity was achieved, the mean of aLDFA and mTFA corrections were determined at 8.9±5.3 and 6.5±3.2 degrees, respectively. The mean speed of aLDFA and mTFA corrections were estimated at 0.8±0.45 and 0.6±0.3 degrees per month, respectively. The postoperative aLDFA and mTFA were measured at 84±4.2 and -0.8±2.9 on average. With a mean of 25.3±14.5 months at final follow-up, there were 6 (17.6%) mild valgus knees, 26 (75.5%) normal alignment knees, and only 2 (5.9%) mild varus knee within an acceptable clinical limit. CONCLUSION: Hemi-epiphysiodesis using X-plate at the distal physis of the femur is an effective and safe method for the treatment of valgus knee deformity in children.