Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Med Phys ; 45(11): 5094-5104, 2018 Nov.
Article in English | MEDLINE | ID: mdl-30247765

ABSTRACT

PURPOSE: In image-guided laparoscopy, optical tracking is commonly employed, but electromagnetic (EM) systems have been proposed in the literature. In this paper, we provide a thorough comparison of EM and optical tracking systems for use in image-guided laparoscopic surgery and a feasibility study of a combined, EM-tracked laparoscope and laparoscopic ultrasound (LUS) image guidance system. METHODS: We first assess the tracking accuracy of a laparoscope with two optical trackers tracking retroreflective markers mounted on the shaft and an EM tracker with the sensor embedded at the proximal end, using a standard evaluation plate. We then use a stylus to test the precision of position measurement and accuracy of distance measurement of the trackers. Finally, we assess the accuracy of an image guidance system comprised of an EM-tracked laparoscope and an EM-tracked LUS probe. RESULTS: In the experiment using a standard evaluation plate, the two optical trackers show less jitter in position and orientation measurement than the EM tracker. Also, the optical trackers demonstrate better consistency of orientation measurement within the test volume. However, their accuracy of measuring relative positions decreases significantly with longer distances whereas the EM tracker's performance is stable; at 50 mm distance, the RMS errors for the two optical trackers are 0.210 and 0.233 mm, respectively, and it is 0.214 mm for the EM tracker; at 250 mm distance, the RMS errors for the two optical trackers become 1.031 and 1.178 mm, respectively, while it is 0.367 mm for the EM tracker. In the experiment using the stylus, the two optical trackers have RMS errors of 1.278 and 1.555 mm in localizing the stylus tip, and it is 1.117 mm for the EM tracker. Our prototype of a combined, EM-tracked laparoscope and LUS system using representative calibration methods showed a RMS point localization error of 3.0 mm for the laparoscope and 1.3 mm for the LUS probe, the lager error of the former being predominantly due to the triangulation error when using a narrow-baseline stereo laparoscope. CONCLUSIONS: The errors incurred by optical trackers, due to the lever-arm effect and variation in tracking accuracy in the depth direction, would make EM-tracked solutions preferable if the EM sensor is placed at the proximal end of the laparoscope.


Subject(s)
Electromagnetic Phenomena , Laparoscopes , Optical Phenomena , Surgery, Computer-Assisted/instrumentation , Ultrasonography/instrumentation , Feasibility Studies
2.
Antiviral Res ; 137: 14-22, 2017 01.
Article in English | MEDLINE | ID: mdl-27838352

ABSTRACT

Zika virus (ZIKV) is currently undergoing pandemic emergence. While disease is typically subclinical, severe neurologic manifestations in fetuses and newborns after congenital infection underscore an urgent need for antiviral interventions. The adenosine analog BCX4430 has broad-spectrum activity against a wide range of RNA viruses, including potent in vivo activity against yellow fever, Marburg and Ebola viruses. We tested this compound against African and Asian lineage ZIKV in cytopathic effect inhibition and virus yield reduction assays in various cell lines. To further evaluate the efficacy in a relevant animal model, we developed a mouse model of severe ZIKV infection, which recapitulates various human disease manifestations including peripheral virus replication, conjunctivitis, encephalitis and myelitis. Time-course quantification of viral RNA accumulation demonstrated robust viral replication in several relevant tissues, including high and persistent viral loads observed in the brain and testis. The presence of viral RNA in various tissues was confirmed by an infectious culture assay as well as immunohistochemical staining of tissue sections. Treatment of ZIKV-infected mice with BCX4430 significantly improved outcome even when treatment was initiated during the peak of viremia. The demonstration of potent activity of BCX4430 against ZIKV in a lethal mouse model warrant its continued clinical development.


Subject(s)
Antiviral Agents/pharmacology , Antiviral Agents/therapeutic use , Purine Nucleosides/pharmacology , Purine Nucleosides/therapeutic use , Zika Virus Infection/drug therapy , Zika Virus/drug effects , Adenine/analogs & derivatives , Adenosine/analogs & derivatives , Animals , Antiviral Agents/administration & dosage , Brain/virology , Cell Line , Disease Models, Animal , Humans , Male , Mice , Purine Nucleosides/administration & dosage , Pyrrolidines , RNA, Viral , Testis/virology , Viral Load/drug effects , Viremia , Virus Replication/drug effects , Zika Virus Infection/virology
3.
Front Hum Neurosci ; 8: 893, 2014.
Article in English | MEDLINE | ID: mdl-25426047

ABSTRACT

Somatosensation as a proximal sense can have a strong impact on our attitude toward physical objects and other human beings. However, relatively little is known about how hedonic valence of touch is processed at the cortical level. Here we investigated the electrophysiological correlates of affective tactile sensation during caressing of the right forearm with pleasant and unpleasant textile fabrics. We show dissociation between more physically driven differential brain responses to the different fabrics in early somatosensory cortex - the well-known mu-suppression (10-20 Hz) - and a beta-band response (25-30 Hz) in presumably higher-order somatosensory areas in the right hemisphere that correlated well with the subjective valence of tactile caressing. Importantly, when using single trial classification techniques, beta-power significantly distinguished between pleasant and unpleasant stimulation on a single trial basis with high accuracy. Our results therefore suggest a dissociation of the sensory and affective aspects of touch in the somatosensory system and may provide features that may be used for single trial decoding of affective mental states from simple electroencephalographic measurements.

4.
Article in English | MEDLINE | ID: mdl-22254963

ABSTRACT

After spinal cord injury, electrical stimulation of the roots inside the spinal column at the level of the cauda equina is a safe and effective way to regain some degree of control over lower body function, e.g. bladder and bowel management and leg movement. The success of current systems used for so-called intrathecal stimulation is limited by the low number of stimulation channels, which are in consequence of the maximum acceptable number of transdural cables. In order to overcome this limitation, we developed an active electrode with integrated electronics, providing four individual stimulation channels that requires one cable only. This paper outlines the different elements of the so-called active book with the emphasis on its preliminary construction and assembly.


Subject(s)
Spinal Cord Injuries/physiopathology , Electrodes , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...