Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Eur J Prosthodont Restor Dent ; 32(2): 183-193, 2024 May 31.
Article in English | MEDLINE | ID: mdl-38691584

ABSTRACT

INTRODUCTION: The purpose of this in vitro study was to evaluate the dimensional accuracy, trueness, and precision of vinyl siloxane ether (VSXE) and polyvinylsiloxane (PVS) impression materials using different impression techniques. MATERIAL AND METHODS: A three-dimensional (3D) printed mandibular model with implants and metal rods served as the reference model. Impressions were taken in custom trays, resulting in four groups: PVS-closed-tray, VSXE-closed-tray, PVS-open-tray, and VSXE-open-tray. The reference model and impressions were scanned and analyzed using 3D analysis software to assess the trueness and precision within each group. RESULTS: There was significant difference in trueness between the groups, with PVS closed tray showing a higher deviation than VSXE-closed-tray and PVS-open-tray. VSXE-open-tray had the lowest deviation, which was statistically significant. In terms of precision, PVS-closed-tray showed the highest deviation, while no significant differences were found among the other groups. CONCLUSIONS: VSXE impression material with an open tray technique consistently demonstrated the highest levels of accuracy and precision. Conversely, PVS impression material with a closed tray technique yielded less favorable results. CLINICAL RELEVANCE: Better understanding of trueness and precision of new impression materials with new impression techniques will increase their clinical effectiveness.


Subject(s)
Dental Impression Materials , Dental Impression Technique , Denture, Overlay , Mandible , Polyvinyls , Siloxanes , Dental Impression Materials/chemistry , Siloxanes/chemistry , Humans , Dental Prosthesis, Implant-Supported , Printing, Three-Dimensional , In Vitro Techniques , Models, Dental
2.
Niger J Clin Pract ; 22(10): 1335-1340, 2019 Oct.
Article in English | MEDLINE | ID: mdl-31607721

ABSTRACT

OBJECTIVE: The purpose of this study was to evaluate the cyclic fatigue resistances of the WaveOne Gold (WOG), ProTaper Next (PTN), 2Shape (TS) instruments. MATERIALS AND METHODS: Totally 45 new WOG (25/.07), PTN (25/.06), TS (25/.06) files were tested inside the artificial canal of a custom-made stainless steel block with an inner diameter of 1.5 mm, a 60° angle, and a 5-mm radius of curvature. A 16-mm-long file segment (from the tip) was introduced and was immersed in 37°C water. The number of cycles to fracture (NCF), time to failure (TTF), fractured fragment length (FL) was recorded and the fractured surface was examined using microscope. RESULTS: WOG > PTN > TS according to TTF results (P = 0.00). PTN > TS according to NCF results (P = 0.00). The FL values showed no significant difference (P = 0.335). CONCLUSIONS: Reciprocating motion can be used more safely than continuous rotation due to the higher cyclic fatigue resistance.


Subject(s)
Dental Alloys , Dental Instruments , Root Canal Preparation/instrumentation , Temperature , Alloys , Dental Stress Analysis , Equipment Failure , Gold , Humans , Nickel , Rotation , Stainless Steel , Titanium
SELECTION OF CITATIONS
SEARCH DETAIL
...