Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add more filters










Database
Language
Publication year range
1.
J Cardiovasc Med (Hagerstown) ; 12(2): 116-21, 2011 Feb.
Article in English | MEDLINE | ID: mdl-21135588

ABSTRACT

BACKGROUND: Radial arterial access is becoming increasingly popular for coronary angiography and angioplasty. The technique is, however, more demanding than femoral arterial access, and hemostasis is not care-free. A quality assurance program was run by our nursing staff, with patient follow-up, to monitor radial arterial access implementation in our laboratory. METHOD: In 973 consecutive patients, both a hydrophilic sheath and an inflatable bandage for hemostasis were used. Bandage inflation volume and time were both reduced through subsequent data audit and protocol changes (A = 175 patients; B = 297; C = 501). RESULTS: An increase was achieved in the percentage of patients with neither loss of radial pulse nor hematoma of any size (A = 81.3%, B = 90.9%, C = 92.2%, P < 0.001), and no discomfort at all (A = 44.2%, B = 75.1%, C = 89.3%, P < 0.001). Follow-up was available for 965 patients (99%), and in 956, the access site could be re-inspected at least once. There were no vascular complications. Overall, the radial artery pulse was absent at latest follow-up in 0.6% of cases (95% confidence interval 0.21-1.05%). In 460 consecutive patients with complete assessment in protocol C, a palpable arterial pulse was absent in 5% of cases at about 20 h after hemostasis. Barbeau's test was positive in 26.5% of patients (95% confidence interval 22.5-30.6%). They had a significantly lower body weight, a lower systolic blood pressure at hemostasis, and a higher bandage inflation volume; a hematoma of any size and the report of any discomfort were also more frequent. Barbeau's test returned to normal in 30% of them 3-60 days later. CONCLUSION: Our nurse-led quality assurance program helped us in reducing minor vascular sequelae and improving patient comfort after radial access. Early occlusion of the radial artery as detected by pulse oxymeter is frequent, often reversible, and may be mostly related to trauma/occlusion of the artery during hemostasis.


Subject(s)
Cardiac Catheterization/nursing , Hemorrhage/prevention & control , Hemostatic Techniques/nursing , Nursing Staff, Hospital/standards , Quality Assurance, Health Care/standards , Radial Artery , Aged , Arterial Occlusive Diseases/etiology , Arterial Occlusive Diseases/prevention & control , Cardiac Catheterization/adverse effects , Chi-Square Distribution , Clinical Audit , Female , Hematoma/etiology , Hematoma/prevention & control , Hemorrhage/etiology , Humans , Italy , Male , Middle Aged , Oximetry/nursing , Punctures , Risk Assessment , Risk Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...