Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 6 de 6
Filter
Add more filters










Database
Language
Publication year range
1.
Lab Chip ; 17(20): 3498-3503, 2017 10 11.
Article in English | MEDLINE | ID: mdl-28932842

ABSTRACT

The interplay between platelets and tumor cells is known to play important roles in metastasis by enhancing tumor cell survival, tumor-vascular interactions, and escape from immune surveillance. However, platelet-covered circulating tumor cells (CTC) are extremely difficult to isolate due to masking or downregulation of surface epitopes. Here we describe a microfluidic platform that takes advantage of the satellite platelets on the surface of these "stealth" CTCs as a ubiquitous surface marker for isolation. Compared to conventional CTC enrichment techniques which rely on known surface markers expressed by tumor cells, platelet-targeted isolation is generally applicable to CTCs of both epithelial and mesenchymal phenotypes. Our approach first depletes unbound, free platelets by means of hydrodynamic size-based sorting, followed by immunoaffinity-based capture of platelet-covered CTCs using a herringbone micromixing device. This method enabled the reliable isolation of CTCs from 66% of lung and 60% of breast cancer (both epithelial) patient samples, as well as in 83% of melanoma (mesenchymal) samples. Interestingly, we observed special populations of CTCs that were extensively covered by platelets, as well as CTC-leukocyte clusters. Because these cloaked CTCs often escape conventional positive and negative isolation mechanisms, further characterization of these cells may uncover important yet overlooked biological information in blood-borne metastasis and cancer immunology.


Subject(s)
Blood Platelets/cytology , Cell Separation/methods , Microfluidic Analytical Techniques/methods , Neoplastic Cells, Circulating/chemistry , Biomarkers, Tumor , Breast Neoplasms/pathology , Epithelial-Mesenchymal Transition , Female , Humans , Immunoassay , Lung Neoplasms/pathology
2.
Sci Rep ; 7(1): 10936, 2017 09 07.
Article in English | MEDLINE | ID: mdl-28883519

ABSTRACT

Circulating tumor cells (CTCs) are a treasure trove of information regarding the location, type and stage of cancer and are being pursued as both a diagnostic target and a means of guiding personalized treatment. Most isolation technologies utilize properties of the CTCs themselves such as surface antigens (e.g., epithelial cell adhesion molecule or EpCAM) or size to separate them from blood cell populations. We present an automated monolithic chip with 128 multiplexed deterministic lateral displacement devices containing ~1.5 million microfabricated features (12 µm-50 µm) used to first deplete red blood cells and platelets. The outputs from these devices are serially integrated with an inertial focusing system to line up all nucleated cells for multi-stage magnetophoresis to remove magnetically-labeled white blood cells. The monolithic CTC-iChip enables debulking of blood samples at 15-20 million cells per second while yielding an output of highly purified CTCs. We quantified the size and EpCAM expression of over 2,500 CTCs from 38 patient samples obtained from breast, prostate, lung cancers, and melanoma. The results show significant heterogeneity between and within single patients. Unbiased, rapid, and automated isolation of CTCs using monolithic CTC-iChip will enable the detailed measurement of their physicochemical and biological properties and their role in metastasis.


Subject(s)
Blood Cells , Cell Separation/methods , Lab-On-A-Chip Devices , Neoplasms/diagnosis , Neoplastic Cells, Circulating , Automation, Laboratory/instrumentation , Automation, Laboratory/methods , Cell Separation/instrumentation , Female , Humans , Male
3.
Sci Rep ; 7(1): 2433, 2017 05 26.
Article in English | MEDLINE | ID: mdl-28550299

ABSTRACT

Circulating tumor cell clusters (CTC clusters) are potent initiators of metastasis and potentially useful clinical markers for patients with cancer. Although there are numerous devices developed to isolate individual circulating tumor cells from blood, these devices are ineffective at capturing CTC clusters, incapable of separating clusters from single cells and/or cause cluster damage or dissociation during processing. The only device currently able to specifically isolate CTC clusters from single CTCs and blood cells relies on the batch immobilization of clusters onto micropillars which necessitates long residence times and causes damage to clusters during release. Here, we present a two-stage continuous microfluidic chip that isolates and recovers viable CTC clusters from blood. This approach uses deterministic lateral displacement to sort clusters by capitalizing on two geometric properties: size and asymmetry. Cultured breast cancer CTC clusters containing between 2-100 + cells were recovered from whole blood using this integrated two-stage device with minimal cluster dissociation, 99% recovery of large clusters, cell viabilities over 87% and greater than five-log depletion of red blood cells. This continuous-flow cluster chip will enable further studies examining CTC clusters in research and clinical applications.


Subject(s)
Cell Separation/methods , Cell Size , Microfluidic Analytical Techniques/methods , Neoplastic Cells, Circulating/pathology , Cell Separation/instrumentation , Cell Survival , Flow Cytometry , Humans , Microfluidic Analytical Techniques/instrumentation , Reproducibility of Results , Single-Cell Analysis/instrumentation , Single-Cell Analysis/methods
4.
Nat Protoc ; 9(3): 694-710, 2014 Mar.
Article in English | MEDLINE | ID: mdl-24577360

ABSTRACT

The ability to isolate and analyze rare circulating tumor cells (CTCs) has the potential to further our understanding of cancer metastasis and enhance the care of cancer patients. In this protocol, we describe the procedure for isolating rare CTCs from blood samples by using tumor antigen-independent microfluidic CTC-iChip technology. The CTC-iChip uses deterministic lateral displacement, inertial focusing and magnetophoresis to sort up to 107 cells/s. By using two-stage magnetophoresis and depletion antibodies against leukocytes, we achieve 3.8-log depletion of white blood cells and a 97% yield of rare cells with a sample processing rate of 8 ml of whole blood/h. The CTC-iChip is compatible with standard cytopathological and RNA-based characterization methods. This protocol describes device production, assembly, blood sample preparation, system setup and the CTC isolation process. Sorting 8 ml of blood sample requires 2 h including setup time, and chip production requires 2-5 d.


Subject(s)
Cell Separation/methods , Microfluidic Analytical Techniques/methods , Neoplastic Cells, Circulating , Humans , Insect Proteins , Magnets
5.
Lab Chip ; 12(17): 3159-67, 2012 Sep 07.
Article in English | MEDLINE | ID: mdl-22763858

ABSTRACT

The ability to control cell-surface interactions in order to achieve binding of specific cell types is a major challenge for microfluidic immunoaffinity cell capture systems. In the majority of existing systems, the functionalized capture surface is constructed of solid materials, where flow stagnation at the solid-liquid interface is detrimental to the convection of cells to the surface. We study the use of ultra-high porosity (99%) nanoporous micro-posts in microfluidic channels for enhancing interception efficiency of particles in flow. We show using both modelling and experiment that nanoporous posts improve particle interception compared to solid posts through two distinct mechanisms: the increase of direct interception, and the reduction of near-surface hydrodynamic resistance. We provide initial validation that the improvement of interception efficiency also results in an increase in capture efficiency when comparing nanoporous vertically aligned carbon nanotube (VACNT) post arrays with solid PDMS post arrays of the same geometry. Using both bacteria (∼1 µm) and cancer cell lines (∼15 µm) as model systems, we found capture efficiency increases by 6-fold and 4-fold respectively. The combined model and experimental platform presents a new generation of nanoporous microfluidic devices for cell isolation.


Subject(s)
Cell Separation/methods , Microfluidic Analytical Techniques/instrumentation , Nanotechnology/instrumentation , Cell Line, Tumor , Cell Separation/instrumentation , Dimethylpolysiloxanes/chemistry , Escherichia coli/isolation & purification , Humans , Microfluidic Analytical Techniques/methods , Nanotubes, Carbon/chemistry , Particle Size , Porosity
6.
Small ; 7(8): 1061-7, 2011 Apr 18.
Article in English | MEDLINE | ID: mdl-21413145

ABSTRACT

Solid materials, such as silicon, glass, and polymers, dominate as structural elements in microsystems including microfluidics. Porous elements have been limited to membranes sandwiched between microchannel layers or polymer monoliths. This paper reports the use of micropatterned carbon-nanotube forests confined inside microfluidic channels for mechanically and/or chemically capturing particles ranging over three orders of magnitude in size. Nanoparticles below the internanotube spacing (80 nm) of the forest can penetrate inside the forest and interact with the large surface area created by individual nanotubes. For larger particles (>80 nm), the ultrahigh porosity of the nanotube elements reduces the fluid boundary layer and enhances particle-structure interactions on the outer surface of the patterned nanoporous elements. Specific biomolecular recognition is demonstrated using cells (≈10 µm), bacteria (≈1 µm), and viral-sized particles (≈40 nm) using both effects. This technology can provide unprecedented control of bioseparation processes to access bioparticles of interest, opening new pathways for both research and point-of-care diagnostics.


Subject(s)
Microfluidics/methods , Nanoparticles/chemistry , Particle Size , Permeability , Porosity
SELECTION OF CITATIONS
SEARCH DETAIL
...