1.
Article in English | MEDLINE | ID: mdl-15027829

ABSTRACT

Tannery effluent is characterized not only by heavy loads but also with toxic heavy metals especially chromium ions. Chromium is considered an important source of contamination due to large volume of exhaust liquid discharged and solid sludge produced. Details on adsorption studies were carried out using synthetic chromium salts (chromium chloride) as adsorbate, and cement kiln dust (a waste from white cement industry) as adsorbent. Equilibrium isotherms have been determined for the adsorption of chromium ions on cement kiln dust. Kinetic study provided that the adsorption process is diffusion controlled. The experimental results have been fitted using Freundlich, Langmuir, and Redlich Peterson isotherms. The maximum adsorption capacity of cement kiln dust was found to be 33 mg/g. Industrial tannery effluent (22-mg/L chromium and COD 952 mg/L) was also treated by cement dust. The treated effluent (using 20 g cement dust per 1 L) contains only 0.6 mg/L chromium and COD 200 mg/L.


Subject(s)
Chromium/isolation & purification , Industrial Waste , Water Pollutants/isolation & purification , Water Purification/methods , Adsorption , Animals , Cattle , Construction Materials , Dust , Skin , Tannins