Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Transplant Proc ; 40(7): 2245-51, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18790205

ABSTRACT

The trial objective was to investigate the feasibility and safety of conversion to a generic microemulsion cyclosporine in stable renal transplant patients premaintained on Neoral. We enrolled 75 patients from seven centers in five Middle Eastern countries monitored them for 6 months after conversion to Sigmasporin Microral. Readings at 0, 0.5, 1, 2, 3, 4.5, and 6 months included cyclosporine blood level, serum creatinine, liver enzymes, lipid profile, blood sugar, blood pressure and adverse events. Patients included 54 men and 21 women of mean age 38.9 +/- 10.7 years at 30.3 +/- 29.3 months post-transplantation maintained on Sigmasporin Microral dose of 2.8 +/- 1.0 mg/kg per day; they were observed to be stable throughout the study period as reflected by the therapeutic blood C0 level of 181.6 +/- 102.1 and C2 of 759.2 +/- 384.4. Their absorption profile as represented by C2/C0 was 4.9 +/- 2.8, and C2/cyclosporine dose of 282.3 +/- 128.8. An average serum creatinine level of 116.1 +/- 29.5 micromol/L denoted stable graft function and their liver enzymes did not change during the study. No new-onset cases of hypertension, diabetes mellitus, or hyperlipidemia were reported among the patients. Graft function was stable for all patients, except for two incidences of mild acute rejection and two of mild cyclosporine nephrotoxicity; graft and patient survival rates were both 100%. Results of this 6-month study showed that Sigmasporin Microral was effective to maintain stable renal function in kidney transplant patients converted from Neoral with similar safety and tolerability profiles as those reported in the literature.


Subject(s)
Cyclosporine/therapeutic use , Kidney Transplantation/immunology , Adult , Aged , Chemistry, Pharmaceutical , Creatinine/blood , Cyclosporine/administration & dosage , Cyclosporine/blood , Drug Therapy, Combination , Female , Follow-Up Studies , Graft Survival/drug effects , Graft Survival/immunology , Humans , Immunosuppressive Agents/administration & dosage , Immunosuppressive Agents/blood , Immunosuppressive Agents/therapeutic use , Kidney Failure, Chronic/surgery , Kidney Function Tests , Kidney Transplantation/physiology , Male , Middle Aged , Patient Compliance , Treatment Outcome
2.
Transplant Proc ; 40(7): 2252-7, 2008 Sep.
Article in English | MEDLINE | ID: mdl-18790206

ABSTRACT

We tested a hypothesized pharmacokinetic difference between the reference (Sandimmun Neoral) and test (Sigmasporin Microral) products to prove therapeutic equivalence in an open, multiple fixed dose, one-way crossover, multicenter, and multinational study over a period of 29 days. Forty two stable renal transplant recipients maintained on Sandimmun Neoral were enrolled. Whole blood was collected at day 14 of the study at 0, 0.5, 1.0, 1.5, 2, 3, 4, 5, 6, 8, 10, and 12 hours after reference dosing and the same schedule was repeated at day 29 after switching on an mg:mg basis to the test product at day 15 of the study. Analysis of variance was performed for the pharmacokinetic parameters (area under the curve [AUC]0-12, maximum concentration [Cmax]) of cyclosporine using log-transformed values. Tolerability was assessed by vital signs, adverse events, and laboratory investigations. The 90% confidence interval (CI) test for the Ln-transformed, pharmacokinetic parameters was all within the US Food and Drug Administration acceptable range of 80% to 125%, as Ln area under the steady-state curve (AUCss) was within the range of 92.56 to 103.55 and Ln Cmax was within the range of 85.73 to 103.58; the same also applied for AUC0-4, which may be considered the area of greatest inter- and intra-patient variability. Furthermore, in line with the newly adopted recommendations of the Expert Advisory Committee on Bioavailability and Bioequivalence of Health Canada, the 90% CI for AUCss was within the narrow range of 90% to 112%. No significant difference in tolerability was recorded between the two products. Sigmasporin Microral (Julphar) was found to be bioequivalent and clinically interchangeable on an mg:mg basis with Sandimmun Neoral (Novartis).


Subject(s)
Cyclosporine/therapeutic use , Kidney Transplantation/immunology , Adult , Chemistry, Pharmaceutical , Cyclosporine/administration & dosage , Cyclosporine/blood , Drugs, Generic/therapeutic use , Emulsions , Female , Humans , Immunosuppressive Agents/administration & dosage , Immunosuppressive Agents/blood , Immunosuppressive Agents/therapeutic use , Kidney Diseases/classification , Kidney Diseases/surgery , Male , Middle Aged
SELECTION OF CITATIONS
SEARCH DETAIL
...