J Cardiovasc Electrophysiol ; 28(10): 1140-1150, 2017 Oct.
Article in English | MEDLINE | ID: mdl-28675629

ABSTRACT

AIMS: The use of left atrial appendage (LAA) occluders in atrial fibrillation is increasing. There are few data on the comparison between transesophageal echocardiography (TEE) and computed tomography (MDCT) assessing peridevice flow and outcome of electrical cardioversion (ECV) in these patients. METHODS AND RESULTS: Single-center prospective registry from 2009 to 2015 including all LAA occluders to analyze success and complications during implantation and follow-up. Patients having ≥1 ECV were further analyzed. TEE was performed during implantation and at 6 weeks. In a subgroup of 77 patients, we compared MDCT with TEE at 6 weeks. Overall, 135 patients (69 ± 9 years; 70% male; CHA2 DS2 -VASc score: 3.6 ± 1.4; HAS-BLED score: 2.5 ± 0.6) received a LAA occluder (Watchman, n = 73; ACP-1, n = 59; Amulet, n = 3; PVI + LAA occluder, n = 91; and LAA occluder only, n = 44). Device implantation was successful in 131 (97%). Eight patients (5.9%) had major periprocedural complications (ischemic stroke/transient ischemic attacks, n = 4, tamponade, n = 2, device thrombosis, n = 2, Dressler syndrome, n = 1). The periprocedural complication rate was similar between concomitant procedure and LAA occluder only (8/91 vs. 5/44; P = 0.6). Twelve patients (9%) died (procedure-related, n = 2; 1%) during follow-up of 44 months (IQR: 43). MDCT (n = 77) at 6 weeks showed similar peridevice flow compared to TEE (TEE: 1.5 ± 1.9 mm vs. MDCT: 1.1 ± 2.2 mm, P = 0.25). Thromboembolic events occurred in 3 patients (CVA, n = 1; TIA, n = 2) during follow-up. In total, 41 ECV were performed in 26 patients (1.6 ± 0.9/patient), 13 months (IQR: 24) after implantation (<1 month: n = 8). No ECV-related clinical complications were observed. CONCLUSION: LAA occlusion is feasible with an acceptable safety profile and few events during long-term follow-up. ECV after LAA occlusion is feasible. MDCT could help to evaluate peridevice flow.


Subject(s)
Atrial Appendage/diagnostic imaging , Atrial Fibrillation/surgery , Blood Vessel Prosthesis Implantation/methods , Echocardiography, Transesophageal/methods , Electric Countershock/methods , Septal Occluder Device , Tomography, X-Ray Computed/methods , Aged , Atrial Appendage/surgery , Atrial Fibrillation/mortality , Blood Vessel Prosthesis , Female , Follow-Up Studies , Humans , Male , Middle Aged , Multimodal Imaging , Postoperative Complications/epidemiology , Predictive Value of Tests , Prospective Studies , Treatment Outcome
2.
Cardiol Res ; 5(6): 163-170, 2014 Dec.
Article in English | MEDLINE | ID: mdl-28352448

ABSTRACT

BACKGROUND: The aim of the study was to prove the concept that correction of established parameters of dyssynchrony is a requirement for favorable long-term outcome in patients with cardiac resynchronization therapy (CRT), whereas patients with persisting dyssynchrony should have a less favorable response. METHODS: After CRT implantation and optimization of dyssynchrony parameters, we evaluated whether correction or persistence of dyssynchrony predicted long-term outcome. Primary endpoint was a combination of cardiac mortality/heart transplantation and hospitalization due to worsening heart failure, and secondary endpoint was NYHA class. RESULTS: One hundred twenty-eight consecutive patients (mean age 68 ± 10 years) undergoing CRT with a mean left ventricular ejection fraction of 27±9% were followed for 27 ± 19 months. All cause mortality was 17.2%, cardiac mortality was 7.8% and 3.1% had to undergo heart transplantation. Rehospitalization due to worsening heart failure was observed in 14.8%. NYHA class before CRT implantation was 2.8 ± 0.8 and improved during follow-up to 2.0 ± 0.8 (P < 0.001). A clinical response was observed in 76% (n = 97) and an echocardiographic response was documented in 66% (n = 85). After individually optimized AV and VV intervals with echocardiography, atrioventricular dyssynchrony was still present in 7.2%, interventricular dyssynchrony in 13.3% and intraventricular dyssynchrony in 16.4%. Despite persistent atrioventricular, interventricular and intraventricular dyssynchrony at long-term follow-up, the combined primary and secondary endpoints did not differ compared to the group without mechanical dyssynchrony (P = ns). QRS duration with biventricular stimulation did not differ between responders vs. nonresponders. CONCLUSION: After successful CRT implantation, clinical long-term response is independent of correction of dyssynchrony measured by echocardiographic parameters and QRS width.

SELECTION OF CITATIONS
SEARCH DETAIL
...