Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 21
Filter
2.
Diagnostics (Basel) ; 11(6)2021 Jun 20.
Article in English | MEDLINE | ID: mdl-34203008

ABSTRACT

MR relaxometry increasingly contributes to liver imaging. Studies on native relaxation times mainly describe relation to the presence of fibrosis. The hypothesis was that relaxation times are also influenced by other inherent factors, including changes in liver synthesis function. With the approval of the local ethics committee and written informed consent, data from 94 patients referred for liver MR imaging, of which 20 patients had cirrhosis, were included. Additionally to standard sequences, both native T1 and T2 parametric maps and T1 maps in the hepatobiliary phase of gadoxetate disodium were acquired. Associations with laboratory variables were assessed. Altogether, there was a negative correlation between albumin and all acquired relaxation times in cirrhotic patients. In non-cirrhotic patients, only T1 values exhibited a negative correlation with albumin. In all patients, bilirubin correlated significantly with post-contrast T1 relaxation times, whereas native relaxation times correlated only in cirrhotic patients. Evaluating patients with pathological INR values, post-contrast relaxation times were significantly higher, whereas native relaxation times did not correlate. In conclusion, apart from confirming the value of hepatobiliary phase T1 mapping, our results show a correlation of native T1 with serum albumin even in non-cirrhotic liver parenchyma, suggesting a direct influence of liver's synthesis capacity on T1 relaxation times.

3.
Radiol Case Rep ; 16(8): 2112-2118, 2021 Aug.
Article in English | MEDLINE | ID: mdl-34158905

ABSTRACT

This case report presents the diagnostic workup of liver malignancy incidentally detected in a 72-year-old male patient on routine body computed tomography angiography (CTA) performed for planning transcatheter aortic valve implantation (TAVI). The patient initially presented to an outside hospital with chest discomfort, where routine diagnostic procedures in the emergency room revealed grade III aortic valve stenosis. Routine CTA for TAVI planning in our department then revealed tumor thrombosis of the portal vein suspicious for hepatic malignancy. In contrast-enhanced ultrasound (CEUS) only the left hepatic lobe was inhomogeneously transformed with early arterial contrast enhancement. Magnetic resonance imaging (MRI) confirmed a primary hepatic malignancy involving the left liver. Transcutaneous biopsy with ultrasound guidance established the diagnosis of hepatocellular carcinoma (HCC). Incidental findings may be of prognostic relevance for the patient and in a number of cases, TAVI can be a prerequisite for the appropriate therapy.

4.
Sci Rep ; 10(1): 20899, 2020 12 01.
Article in English | MEDLINE | ID: mdl-33262372

ABSTRACT

Radiographs are the clinical first line imaging modality for evaluating hip morphology and pathology. MRI offers additional information and is the method of choice to evaluate soft tissue, bone marrow and preradiographic signs of osteoarthritis. Radiographs are used to measure the most morphometric parameters. The aim of this study was to compare susceptibility weighted MRI (SWMR) with radiographs to evaluate hip morphology. 40 Patients were examined with standard MR-sequences, coronal SWMR and radiographs in anteroposterior pelvic view. Coronal maximum intensity projection (MIP) images of both hips were automatically reconstructed on SWMR and T1weighted images. Sharp´s angle, Tönnis angle, lateral center-edge angle of Wiberg and caput-collum-diaphyseal angle were measured on coronal SWMR MIP-images, T1weighted MIP-images and radiographs. Measurements were compared by linear regression analysis and Bland-Altmann Plots, using radiographs as reference standard. Additionally, a ratio between the signal intensity of muscles and bone on SWMR and T1weighted MIP-images was calculated and compared between these two sequences. SWMR enables the reliable assessment of Sharp´s angle (SWMR: R2 = 0.80; T1weighted: R2 = 0.37), Tönnis angle (SWMR: R2 = 0.86; T1weighted: not measurable), lateral center-edge angle of Wiberg (SWMR: R2 = 0.88; T1weighted: R2 = 0.40) and caput-collum-diaphyseal angle (SWMR: R2 = 0.38; T1weighted: R2 = 0.18) compared to radiographs with a higher accuracy than conventional MR imaging. The ratio between the intensity of muscles and bone was significant higher on SWMR (2.00 and 2.02) than on T1weighted MIP-images (1.6 and 1.42; p < 0.001).


Subject(s)
Hip Joint/diagnostic imaging , Magnetic Resonance Imaging/methods , Tomography, X-Ray Computed/methods , Adult , Aged , Female , Hip Joint/anatomy & histology , Hip Joint/pathology , Humans , Male , Middle Aged , Observer Variation , Prospective Studies , X-Rays , Young Adult
5.
Sci Rep ; 10(1): 18104, 2020 10 22.
Article in English | MEDLINE | ID: mdl-33093649

ABSTRACT

Previous studies have shown gadoxetate disodium's potential to represent liver function by its retention in the hepatobiliary phase. Additionally, in cardiac imaging, quantitative characterization of altered parenchyma is established by extracellular volume (ECV) calculation with extracellular contrast agents. Therefore, the purpose of our study was to evaluate whether intracellular accumulation capacity (IAC) of gadoxetate disodium derived from ECV calculation provides added scientific value in terms of liver function compared to the established parameter reduction rate (RR). After local review board approval, 105 patients undergoing standard MR examination with gadoxetate disodium were included. Modified Look-Locker sequences were obtained before and 20 min after contrast agent administration. RR and IAC were calculated and correlated with serum albumin, as a marker of synthetic liver function. Correlation was higher between IAC and albumin, than between RR and albumin. Additionally, capacity of both RR and IAC to distinguish between patients with or without liver cirrhosis was investigated, and differed significantly in their respective means between patients with cirrhosis and those without. We concluded, that the formula to calculate ECV can be transferred to calculate IAC of gadoxetate disodium in hepatocytes, and, thereby, IAC may possibly qualify as an imaging-based parameter to estimate synthetic liver function.


Subject(s)
Biomarkers/metabolism , Contrast Media/metabolism , Gadolinium DTPA/metabolism , Liver Cirrhosis/pathology , Liver/metabolism , Magnetic Resonance Imaging/methods , Case-Control Studies , Female , Humans , Image Processing, Computer-Assisted/methods , Liver Cirrhosis/metabolism , Male , Middle Aged , Prospective Studies
6.
Int J Chron Obstruct Pulmon Dis ; 15: 1877-1886, 2020.
Article in English | MEDLINE | ID: mdl-32801683

ABSTRACT

Purpose: The aim of this retrospective study was to evaluate correlations between parameters of quantitative computed tomography (QCT) analysis, especially the 15th percentile of lung attenuation (P15), and parameters of clinical tests in a large group of patients with pulmonary emphysema. Patients and Methods: One hundred and seventy-two patients with pulmonary emphysema and chronic obstructive pulmonary disease (COPD) global initiative for chronic obstructive lung disease (GOLD) stage 3 or 4 were assessed by nonenhanced thin-section CT scans in full inspiratory and expiratory breath-hold, pulmonary function test (PFT), a 6-minute walk test (6MWT), and quality of life questionnaires (SGRQ and CAT). QCT parameters included total lung volume (TLV), total emphysema score (TES), and P15, all measured at inspiration (IN) and expiration (EX). Differences between inspiration and expiration were calculated for TLV (TLVDiff), TES (TESDiff), and P15 (P15Diff). Spearman correlation analysis was performed. Results: CT-measured lung volume in inspiration (TLVIN) correlated strongly with spirometry-measured total lung capacity (TLC) (r=0.81, p<0.001) and moderately to strongly with residual volume (RV), forced vital capacity (FVC), and forced expiratory volume in 1 second (FEV1)/FVC (r=0.60, 0.56, and -0.49, each p<0.001). Lung volume in expiration (TLVEX) correlated moderately to strongly with TLC, RV and FEV1/FVC ratio (r=0.75, 0.66, and -0.43, each p<0.001). TES and P15 showed stronger correlations with the carbon monoxide transfer coefficient (KCO%) (r= -0.42, 0.44, both p<0.001), when measured during expiration. P15Diff correlated moderately with KCO% and carbon monoxide diffusing capacity (DLCO%) (r= 0.41, 0.40, both p<0.001). The 6MWT and most QCT parameters showed significant differences between COPD GOLD 3 and 4 groups. Conclusion: Our results suggest that QCT can help predict the severity of lung function decrease in patients with pulmonary emphysema and COPD GOLD 3 or 4. Some QCT parameters, including P15EX and P15Diff, correlated moderately to strongly with parameters of pulmonary function tests.


Subject(s)
Pulmonary Disease, Chronic Obstructive , Pulmonary Emphysema , Forced Expiratory Volume , Humans , Lung/diagnostic imaging , Pulmonary Disease, Chronic Obstructive/diagnostic imaging , Pulmonary Emphysema/diagnostic imaging , Quality of Life , Retrospective Studies , Tomography, X-Ray Computed
7.
Sci Rep ; 10(1): 12889, 2020 07 30.
Article in English | MEDLINE | ID: mdl-32733016

ABSTRACT

Adjacent to hepatic metastases, liver parenchyma is often histopathologically altered even if its visual appearance on native magnetic resonance (MR) images is blunt. Yet, relaxation properties in MR imaging may show structural changes prior to visual alteration, and therefore, the aim of this study was to investigate whether T1 relaxation times in the perilesional zone differ between metastases and benign lesions. A total of 113 patients referred for MRI were included prospectively. Images were assessed for metastases, solid benign lesions and cysts, and regions-of-interest were drawn on T1 maps including the focal lesion and a close (inner perilesional zone = IPZ) and a larger perilesional zone (outer perilesional zone = OPZ). Simple ratios between these zones, as well as a gradient ratio between the IPZ and the entire perilesional zone (EPZ) were calculated. Within the collective, 44 patients had lesions of one or two entities. For metastases, the simple ratio between IPZ and OPZ as well as the mean EPZ gradient was significantly higher than for both solid benign lesions and cysts. Lesion size was not a significant covariate. We conclude, that native T1 properties of the perilesional zones differ significantly between malignant and both solid and cystic benign lesions.


Subject(s)
Cysts/diagnostic imaging , Liver Neoplasms , Liver/diagnostic imaging , Magnetic Resonance Imaging , Adult , Aged , Aged, 80 and over , Female , Humans , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/secondary , Male , Middle Aged , Neoplasm Metastasis , Prospective Studies
8.
J Clin Med ; 9(5)2020 May 21.
Article in English | MEDLINE | ID: mdl-32455558

ABSTRACT

BACKGROUND: Magnetic resonance relaxometry (MRR) offers highly reproducible pixel-wise parametric maps of T1 and T2 relaxation times, reflecting specific tissue properties, while diffusion-tensor imaging (DTI) is a promising technique for the characterization of microstructural changes, depending on the directionality of molecular motion. Both MMR and DTI may be used for non-invasive assessment of parenchymal changes caused by kidney injury or graft dysfunction. METHODS: We examined 46 patients with kidney transplantation and 16 healthy controls, using T1/T2 relaxometry and DTI at 3 T. Twenty-two early transplants and 24 late transplants were included. Seven of the patients had prior renal biopsy (all of them dysfunctional allografts; 6/7 with tubular atrophy and 7/7 with interstitial fibrosis). RESULTS: Compared to healthy controls, T1 and T2 relaxation times in the renal parenchyma were increased after transplantation, with the highest T1/T2 values in early transplants (T1: 1700 ± 53 ms/T2: 83 ± 6 ms compared to T1: 1514 ± 29 ms/T2: 78 ± 4 ms in controls). Medullary and cortical ADC/FA values were decreased in early transplants and highest in controls, with medullary FA values showing the most pronounced difference. Cortical renal T1, mean medullary FA and corticomedullary differentiation (CMD) values correlated best with renal function as measured by eGFR (cortical T1: r = -0.63, p < 0.001; medullary FA: r = 0.67, p < 0.001; FA CMD: r = 0.62, p < 0.001). Mean medullary FA proved to be a significant predictor for tubular atrophy (p < 0.001), while cortical T1 appeared as a significant predictor of interstitial fibrosis (p = 0.003). CONCLUSION: Cortical T1, medullary FA, and FA CMD might serve as new imaging biomarkers of renal function and histopathologic microstructure.

9.
AJR Am J Roentgenol ; 214(4): 747-753, 2020 04.
Article in English | MEDLINE | ID: mdl-31913067

ABSTRACT

OBJECTIVE. The purpose of this study is to compare the image quality, including artifacts, of a T1-weighted gradient-recalled echo (GRE) MRI sequence with a radial sampling approach to that of both 2D turbo spin-echo (TSE) and cartesian 3D GRE MRI sequences performed in the head and neck region. MATERIALS AND METHODS. The retrospective study included 26 datasets of patients who underwent MRI examination for inflammatory or neoplastic diseases of the head and neck region performed using a 1.5-T system. All examination protocols comprised three fat-saturated T1-weighted sequences performed in the axial plane after contrast agent administration. Axial FOV and spatial resolution in plane and along the z-axis were recorded. Sequences were evaluated independently by two readers for qualitative and quantitative parameters, including homogeneity of fat saturation and discrimination of pharyngeal wall structures. Qualitative parameters were evaluated using a 5-point Likert scale. RESULTS. For comparison, mean values of Likert scale scores were generated from the two readers' data. Fat saturation was significantly better on the radial GRE sequences (1.942) than on the TSE (2.346; p = 0.002) and cartesian GRE (2.365; p = 0.008) sequences. The overall impact of foreign material artifacts was comparable among sequences (radial GRE, 1.731; TSE, 1.731 [p = 1.000]; cartesian GRE, 1.769 [p = 0.414]); however, on direct comparison, the mean area that was not evaluable because of susceptibility was smaller on radial GRE sequences (53.8 mm) than on TSE sequences (59.8 mm; p = 0.062) and cartesian GRE sequences (59.6 mm; p = 0.079). Overall image quality was 1.635 with the use of radial GRE, 2.423 with TSE (p = 0.000), and 2.500 with cartesian GRE (p = 0.000). CONCLUSION. For imaging of the head and neck region, radial GRE has several advantages, including improved fat saturation and reduced extent of susceptibility artifacts, compared with TSE and cartesian GRE, leading to improved overall image quality.


Subject(s)
Head and Neck Neoplasms/diagnostic imaging , Imaging, Three-Dimensional/methods , Magnetic Resonance Imaging/methods , Artifacts , Contrast Media , Female , Humans , Inflammation , Male , Middle Aged , Retrospective Studies
10.
Cancer Imaging ; 19(1): 35, 2019 Jun 07.
Article in English | MEDLINE | ID: mdl-31174616

ABSTRACT

BACKGROUND: Correct staging and grading of patients with clear cell renal cell carcinoma (cRCC) is of clinical relevance for the prediction of operability and for individualized patient management. As partial or radial resection with postoperative tumor grading currently remain the methods of choice for the classification of cRCC, non-invasive preoperative alternatives to differentiate lower grade from higher grade cRCC would be beneficial. METHODS: This institutional-review-board approved cross-sectional study included twenty-seven patients (8 women, mean age ± SD, 61.3 ± 14.2) with histopathologically confirmed cRCC, graded according to the International Society of Urological Pathology (ISUP). A native, balanced steady-state free precession T2 mapping sequence (TrueFISP) was performed at 1.5 T. Quantitative T2 values were measured with circular 2D ROIs in the solid tumor portion and also in the normal renal parenchyma (cortex and medulla). To estimate the optimal cut-off T2 value for identifying lower grade cRCC, a Receiver Operating Characteristic Curve (ROC) analysis was performed and sensitivity and specificity were calculated. Students' t-tests were used to evaluate the differences in mean values for continuous variables, while intergroup differences were tested for significance with two-tailed Mann-Whitney-U tests. RESULTS: There were significant differences between the T2 values for lower grade (ISUP 1-2) and higher grade (ISUP 3-4) cRCC (p < 0.001), with higher T2 values for lower grade cRCC compared to higher grade cRCC. The sensitivity and specificity for the differentiation of lower grade from higher grade tumors were 83.3% (95% CI: 0.59-0.96) and 88.9% (95% CI: 0.52-1.00), respectively, using a threshold value of ≥110 ms. Intraobserver/interobserver agreement for T2 measurements was excellent/substantial. CONCLUSIONS: Native T2 mapping based on a balanced steady-state free precession MR sequence might support an image-based distinction between lower and higher grade cRCC in a two-tier-system and could be a helpful addition to multiparametric imaging.


Subject(s)
Carcinoma, Renal Cell/diagnostic imaging , Kidney Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Aged , Carcinoma, Renal Cell/pathology , Female , Humans , Image Interpretation, Computer-Assisted/methods , Kidney Neoplasms/pathology , Male , Middle Aged , Neoplasm Grading , Sensitivity and Specificity
11.
Eur Radiol ; 29(11): 5832-5843, 2019 Nov.
Article in English | MEDLINE | ID: mdl-30887194

ABSTRACT

OBJECTIVES: To assess the potential of T1 mapping-based extracellular volume fraction (ECV) for the identification of higher grade clear cell renal cell carcinoma (cRCC), based on histopathology as the reference standard. METHODS: For this single-center, institutional review board-approved prospective study, 27 patients (17 men, median age 62 ± 12.4 years) with pathologic diagnosis of cRCC (nucleolar International Society of Urological Pathology (ISUP) grading) received abdominal MRI scans at 1.5 T using a modified Look-Locker inversion recovery (MOLLI) sequence between January 2017 and June 2018. Quantitative T1 values were measured at different time points (pre- and postcontrast agent administration) and quantification of the ECV was performed on MRI and histological sections (H&E staining). RESULTS: Reduction in T1 value after contrast agent administration and MR-derived ECV were reliable predictors for differentiating higher from lower grade cRCC. Postcontrast T1diff values (T1diff = T1 difference between the native and nephrogenic phase) and MR-derived ECV were significantly higher for higher grade cRCC (ISUP grades 3-4) compared with lower grade cRCC (ISUP grades 1-2) (p < 0.001). A cutoff value of 700 ms could distinguish higher grade from lower grade tumors with 100% (95% CI 0.69-1.00) sensitivity and 82% (95% CI 0.57-0.96) specificity. There was a positive and strong correlation between MR-derived ECV and histological ECV (p < 0.01, r = 0.88). Interobserver agreement for quantitative longitudinal relaxation times in the T1 maps was excellent. CONCLUSIONS: T1 mapping with ECV measurement could represent a novel in vivo biomarker for the classification of cRCC regarding their nucleolar grade, providing incremental diagnostic value as a quantitative MR marker. KEY POINTS: • Reduction in MRI T1 relaxation times after contrast agent administration and MR-derived extracellular volume fraction are useful parameters for grading of clear cell renal cell carcinoma (cRCC). • T1 differences between the native and the nephrogenic phase are higher for higher grade cRCC compared with lower grade cRCC and MRI-derived extracellular volume fraction (ECV) and histological ECV show a strong correlation. • T1 mapping with ECV measurement may be helpful for the noninvasive assessment of cRCC pathology, being a safe and feasible method, and it has potential to optimize individualized treatment options, e.g., in the decision of active surveillance.


Subject(s)
Carcinoma, Renal Cell/pathology , Kidney Neoplasms/pathology , Kidney/pathology , Magnetic Resonance Imaging/methods , Neoplasm Staging/methods , Female , Humans , Male , Middle Aged , Prospective Studies , ROC Curve , Reproducibility of Results
12.
PLoS One ; 14(3): e0213408, 2019.
Article in English | MEDLINE | ID: mdl-30840710

ABSTRACT

BACKGROUND: Detection of metastases can have a significant impact on therapy. Nevertheless, even in gadoxetate disodium-enhanced MR scans, very small hepatic metastases may be difficult to see. PURPOSE: To investigate the potential of a contrast-optimised (phase-sensitive) inversion recovery MR sequence in gadoxetate disodium-enhanced scans for detection of hepatic metastases. MATERIALS AND METHODS: With institutional review board approval and after written informed consent, 40 patients (18 male, 22 female) with suspected or known hepatic metastases were examined on a 1.5 T MR system. A T1-weighted gradient-echo volumetric-interpolated-breath-hold (VIBE) sequence was acquired as part of the standard imaging protocol 20 minutes after administration of gadoxetate disodium. Additionally, an IR sequence was acquired with an inversion time to suppress native signal from metastases. Overall image quality and delineation of lesions were assessed on VIBE as well as on magnitude-reconstructed (MAG) and phase-sensitive IR (PSIR) sequences. Lesion-to-liver contrast (LLC) was compared between VIBE and MAG images. RESULTS: Overall image quality was high in both VIBE and MAG IR sequences (VIBE 4.275; MAG 4.313), yet significantly lower in PSIR (4.038). Subjective delineation of lesions was higher on MAG and PSIR images compared to VIBE in all size groups with an overall statistically significant difference for VIBE vs. MAG vs. PSIR (p < .001) in the variance analysis. Mean LLC was 0.35±0.01 for VIBE sequences, and 0.73±0.01 for MAG. CONCLUSION: Contrast-optimised PSIR seems to improve imaging characteristics of hepatic metastases in gadoxetate disodium-enhanced scans compared to T1 gradient-echo VIBE sequences.


Subject(s)
Image Enhancement/methods , Liver Neoplasms/diagnostic imaging , Liver Neoplasms/secondary , Magnetic Resonance Imaging/methods , Adult , Aged , Aged, 80 and over , Breath Holding , Contrast Media , Female , Gadolinium DTPA , Humans , Liver/diagnostic imaging , Male , Middle Aged , Prospective Studies
13.
Eur Radiol ; 29(4): 1855-1862, 2019 Apr.
Article in English | MEDLINE | ID: mdl-30324384

ABSTRACT

OBJECTIVE: The aim of this study was to evaluate the diagnostic performance of susceptibility-weighted magnetic resonance imaging (SW-MRI) for the evaluation of osseous foraminal stenosis (FS) of the cervical spine compared to conventional MRI-sequences, using computed tomography (CT) as a reference standard. MATERIALS AND METHODS: Twenty-one patients with suspected radiculopathy of the cervical spine were prospectively included. CT and MRI data sets were available for all patients. As standard of reference, 280 neuroforamina of the cervical spine, including 58 foraminal stenosis, were identified on sagittal CT images. T1-, T2-, and SW-MRI of the cervical spine were performed. The presence of foraminal stenosis was assessed on sagittal views in all sequences. Sensitivity and specificity were calculated and differences in detection rate and severity scoring of foraminal stenosis between the different sequences were tested. CT was used as reference standard for all analysis. RESULTS: Fifty-six of 58 osseous foraminal stenosis could be correctly identified on SW-MR magnitude images. SW-MRI achieved a sensitivity of 96.6% and specificity of 99.5% for the identification of foraminal stenosis. In comparison, conventional T1-weighted MRI sequences achieved a sensitivity and specificity of 43.1% and 100% respectively. T2-weighted MRI sequences achieved a sensitivity and specificity of 65.5% and 99.1%, respectively. The overall detection rate was significantly (p < 0.05) higher on SW-MRI and there was no significant difference (p > 0.05) in severity scoring compared to CT. T1- and T2-weighted MRI underestimated the degree of foraminal stenosis. Intermodality and interobserver agreements were highest for SW-MRI. CONCLUSIONS: SW-MRI enables the reliable detection of osseous foraminal stenosis of the cervical spine in patients with spinal radiculopathy with a higher sensitivity compared to conventional T1- and T2-MRI sequences, with CT as a reference standard. KEY POINTS: • Susceptibility-weighted magnetic resonance imaging enables the reliable detection of osseous foraminal stenosis of the cervical spine with CT as a reference standard. • This could be relevant for younger patients in order to prevent unnecessary radiation exposure. • This may also facilitate a one-stop-shop approach and speed up diagnostic work-up.


Subject(s)
Cervical Vertebrae/diagnostic imaging , Magnetic Resonance Imaging/methods , Radiculopathy/diagnostic imaging , Spinal Stenosis/diagnostic imaging , Adult , Aged , Female , Humans , Male , Middle Aged , Prospective Studies , Radiation Exposure , Radiculopathy/complications , Sensitivity and Specificity , Spinal Stenosis/complications , Tomography, X-Ray Computed
14.
Invest Radiol ; 54(2): 118-128, 2019 02.
Article in English | MEDLINE | ID: mdl-30379727

ABSTRACT

OBJECTIVES: The aims of this study were to identify higher-grade clear cell renal cell carcinoma (cRCC) with native T1 mapping and to histologically correlate the results with the collagen volume fraction. MATERIALS AND METHODS: For this institutional review board-approved, single-center prospective study, 68 consecutive patients received abdominal magnetic resonance imaging scans at 1.5 T between January 2017 and July 2018, using a Modified Look-Locker Inversion Recovery (MOLLI) sequence. Thirty patients with cRCC (20 men; mean age, 61.9 ± 13.1 years) who underwent partial or radical nephrectomy and histological grading according to the International Society of Urological Pathology (ISUP) classification and a separate healthy cohort of 30 individuals without renal malignancies or complex cysts (16 men; mean age, 59.7 ± 14.6 years) met the eligibility criteria. T1 values were quantitatively measured with region of interest measurements in T1 maps. Quantification of the collagen volume fraction was performed on histological sections (picrosirius red staining). RESULTS: Native T1 values were significantly lower for lower-grade cRCC (ISUP 1 and 2) compared with higher-grade cRCC (ISUP 3 and 4; P < 0.001). A cutoff value of 1101 milliseconds distinguished higher-grade from lower-grade tumors with a sensitivity of 100% (95% confidence interval [CI], 0.69-1.00), a specificity of 85% (95% CI, 0.62-0.97), and an accuracy of 90% (95% CI, 0.73-0.98). Native T1 values were significantly associated with the histological collagen volume fraction (P < 0.05). Furthermore, T1 times in the renal cortex, medulla, and tumor tissue showed an excellent interobserver agreement. CONCLUSIONS: Native T1 mapping could represent an in vivo biomarker for the differentiation of lower- and higher-grade cRCCs, providing incremental diagnostic value beyond qualitative magnetic resonance imaging features.


Subject(s)
Carcinoma, Renal Cell/diagnostic imaging , Image Interpretation, Computer-Assisted/methods , Kidney Neoplasms/diagnostic imaging , Magnetic Resonance Imaging/methods , Biomarkers , Carcinoma, Renal Cell/pathology , Cohort Studies , Female , Humans , Kidney/diagnostic imaging , Kidney/pathology , Kidney Neoplasms/pathology , Male , Middle Aged , Predictive Value of Tests , Prospective Studies , Reproducibility of Results , Sensitivity and Specificity
16.
Radiology ; 290(1): 146-154, 2019 01.
Article in English | MEDLINE | ID: mdl-30375926

ABSTRACT

Purpose To evaluate the use of susceptibility-weighted MRI for the differentiation of predominantly osteoblastic and osteolytic spine metastases. Materials and Methods For this prospective study, 53 study participants (mean age, 54.5 years ± 14.3 [range, 22-88 years]; 27 men with a mean age of 55.3 years ± 12.7 [range, 22-72 years] and 26 women with a mean age of 53.8 years ± 15.7 [range, 23-88 years]) with clinically suspected spine metastases underwent imaging with standard MRI sequences, susceptibility-weighted MRI, and CT. Sensitivities and specificities of MRI sequences for the detection of predominantly osteoblastic and osteolytic metastases were determined by using CT as the reference standard. The metastases-to-vertebral body signal intensity ratio (MVR) was calculated to compare modalities. Phantom measurements were obtained to correlate bone densities between MRI sequences and CT. Results A total of 64 metastases (38 predominantly osteoblastic, 26 predominantly osteolytic) were detected. Susceptibility-weighted MRI achieved a sensitivity of 100% (38 of 38) and specificity of 96% (25 of 26) for predominantly osteoblastic metastases and a sensitivity of 96% (25 of 26) and specificity of 100% (38 of 38) for predominantly osteolytic metastases. Standard MRI sequences achieved a sensitivity of 89% (34 of 38) and specificity of 73% (19 of 26) for predominantly osteoblastic metastases and a sensitivity of 73% (19 of 26) and specificity of 92% (35 of 38) for predominantly osteolytic metastases. MVR measurements obtained with susceptibility-weighted MRI demonstrated a strong correlation with those obtained with CT (R2 = 0.75), whereas those obtained with T1-weighted MRI, T2-weighted MRI, and turbo inversion-recovery magnitude MRI showed a weak to moderate correlation (R2 = 0.00, R2 = 0.35, and R2 = 0.39, respectively). Susceptibility-weighted MRI showed a strong correlation with CT with regard to metastases size (R2 = 0.91). In phantom measurements, susceptibility-weighted MRI enabled the reliable differentiation of different degrees of mineralization (R2 = 0.92 compared with CT). Conclusion Susceptibility-weighted MRI enables the reliable differentiation between predominantly osteoblastic and osteolytic spine metastases with a higher accuracy than standard MRI sequences. © RSNA, 2018 Online supplemental material is available for this article. See also the editorial by Schweitzer in this issue.


Subject(s)
Image Interpretation, Computer-Assisted/methods , Magnetic Resonance Imaging/methods , Spinal Neoplasms , Adult , Aged , Aged, 80 and over , Bone Neoplasms/pathology , Diagnosis, Differential , Female , Humans , Male , Middle Aged , Osteolysis/diagnostic imaging , Phantoms, Imaging , Prospective Studies , Sensitivity and Specificity , Spinal Neoplasms/classification , Spinal Neoplasms/diagnostic imaging , Spinal Neoplasms/secondary , Tomography, X-Ray Computed , Young Adult
17.
PLoS One ; 13(9): e0203476, 2018.
Article in English | MEDLINE | ID: mdl-30183778

ABSTRACT

AIM: To compare the potential of a gadoxetate disodium enhanced navigator-triggered 3D T1 magnetic-resonance cholangiography (MRC) sequence with a specific inversion recovery prepulse to T2-weighted MRCP for assessment of the hepatobiliary system. MATERIALS AND METHODS: 30 patients (12 male, 18 female) prospectively underwent conventional navigator-triggered 3D turbo spin-echo T2-weighted MRCP and 3D T1 MRC with a specific inversion pulse to minimise signal from the liver 30 minutes after administration of gadoxetate disodium on a 1.5 T MRI system. For qualitative evaluation, biliary duct depiction was assessed segmentally following a 5-point Likert scale. Visualisation of hilar structures as well as image quality was recorded. Additionally, the extrahepatic bile ducts were assessed quantitatively by calculation of signal-to-noise ratios (SNR). RESULTS: The advantages of T1 3D MRC include reduced affection of image quality by bowel movement and robust depiction of the relative position of the extrahepatic bile ducts in relation to the portal vein and the duodenum compared to T2 MRCP. However, overall T1 3D MRC did not significantly (p > 0.05) improve the biliary duct depiction compared to T2 MRCP in all segments: Common bile duct 4.1 vs. 4.4, right hepatic duct 3.6 vs. 4.2, left hepatic duct 3.5 vs. 4.1. Image quality did not differ significantly (p > 0.05) between both sequences (3.6 vs. 3.5). SNR measurements for the hepatobiliary system did not differ significantly (p > 0.05) between navigator-triggered T1 3D MRC and T2 MRCP. CONCLUSIONS: This preliminary study demonstrates that T1 3D MRC of a specific inversion recovery prepulse has potential to complement T2 MRCP, especially for the evaluation of liver structures close to the hilum in the diagnostic work-up of the biliary system in patients receiving gadoxetate disodium.


Subject(s)
Biliary Tract/diagnostic imaging , Cholangiography/methods , Gadolinium DTPA/administration & dosage , Magnetic Resonance Imaging/methods , Adult , Aged , Female , Humans , Male , Middle Aged
18.
Acta Radiol ; 59(2): 161-169, 2018 Feb.
Article in English | MEDLINE | ID: mdl-28513211

ABSTRACT

Background Computed tomography (CT) of the left atrium (LA) is performed prior to pulmonary vein isolation (PVI) to improve success of circumferential ablation for atrial fibrillation. The ablation procedure itself exposes patients to substantial radiation doses, therefore radiation dose reduction in pre-ablational imaging is of concern. Purpose To assess and compare diagnostic performance of low-radiation dose preprocedural CT in patients scheduled for PVI using two types of reconstruction algorithms. Material and Methods Forty-six patients (61 ± 10 years) scheduled for PVI were enrolled in this study irrespective of body-mass-index or cardiac rhythm at examination. An electrocardiographically triggered dual-source CT scan was performed. Filtered back projection (FBP) and iterative reconstruction (IR) algorithms were applied. Images were integrated into an electroanatomic mapping (EAM) system. Subjective image quality was scored independently by two readers on a five-point scale for both reconstruction algorithms (1 = excellent to 5 = non-diagnostic). Signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR), and effective radiation dose were calculated. Results Data acquisition and EAM integration were successful in all patients. Median image quality score was 1 for both FBP (quartiles = 1, 1.62; range = 1-3) and IR (quartiles = 1, 1.5; range = 1-3). Mean SNR was 7.61 ± 2.14 for FBP and 9.02 ± 2.69 for IR. Mean CNR was 5.92 ± 1.80 for FBP and 6.95 ± 2.29 for IR. Mean effective radiation dose was 0.3 ± 0.1 mSv. Conclusion At a radiation dose of 0.3 ± 0.1 mSv, high-pitch dual-source CT yields LA images of consistently high quality using both FBP and IR. IR raises SNR and CNR without significantly improving subjective image quality.


Subject(s)
Heart Atria , Pulmonary Veins/surgery , Tomography, X-Ray Computed/methods , Algorithms , Atrial Fibrillation/surgery , Electrocardiography , Female , Humans , Male , Middle Aged , Radiation Dosage
19.
Eur J Radiol ; 85(8): 1414-20, 2016 Aug.
Article in English | MEDLINE | ID: mdl-27423681

ABSTRACT

BACKGROUND: The aim of our retrospective study was to determine whether a dedicated software for assessment of airway morphology can detect differences in airway dimensions between patients with and without bronchiolitis obliterans syndrome (BOS), regarded as the clinical correlate of chronic lung allograft rejection. METHODS: 12 patients with and 14 patients without diagnosis of BOS were enrolled in the study. Evaluation of bronchial wall area percentage (WA%) and bronchial wall thickness (WT) in all follow-up CT scans was performed using a semiautomatic airway assessment tool. We assessed temporal changes (ΔWA%, ΔWT) and compared these morphological parameters with forced expiratory volume in one second (ΔFEV1). RESULTS: In patients with and without BOS, the temporal changes over the entire follow-up were 26.6% versus 16.2% for ΔFEV1 (p=0.034), 14.2% versus 5.4% for ΔWA% (p=0.003) and 0.212mm versus 0.064mm for ΔWT (p=0.011). CONCLUSIONS: We detected significant differences of the temporal changes of airway dimensions (ΔWA%, ΔWT) between lung transplant recipients with and without BOS. We conclude that computer-assisted bronchial wall measurements in CT scans might complement the information from pulmonary function tests and establish as a non-invasive method to confirm BOS in lung transplant recipients in the future.


Subject(s)
Allografts/transplantation , Bronchiolitis Obliterans/surgery , Image Processing, Computer-Assisted/methods , Lung Transplantation/methods , Lung/diagnostic imaging , Tomography, X-Ray Computed/methods , Adult , Allografts/diagnostic imaging , Bronchi/diagnostic imaging , Bronchi/pathology , Bronchiolitis Obliterans/diagnostic imaging , Cystic Fibrosis/diagnostic imaging , Cystic Fibrosis/surgery , Female , Follow-Up Studies , Forced Expiratory Volume/physiology , Humans , Hypertension, Pulmonary/diagnostic imaging , Hypertension, Pulmonary/surgery , Lung/pathology , Lung/physiology , Male , Middle Aged , Pulmonary Emphysema/diagnostic imaging , Pulmonary Emphysema/surgery , Pulmonary Fibrosis/diagnostic imaging , Pulmonary Fibrosis/surgery , Respiratory Function Tests , Retrospective Studies , Syndrome
20.
Invest Radiol ; 51(1): 33-40, 2016 Jan.
Article in English | MEDLINE | ID: mdl-26322554

ABSTRACT

OBJECTIVE: The aim of the study was to evaluate image quality of a dynamic hepatic magnetic resonance (MR) imaging strategy based on advanced parallel acquisition combined with rhythmic breath-hold and gadoxetate disodium enhancement. MATERIALS AND METHODS: Twenty-seven patients (21 male/6 female; mean age, 57.3 years) were enrolled in this institutional review board-approved study and underwent MR imaging at 3 T. The sequence (T1 3-dimensional gradient-recalled echo; acceleration factor, 4; reconstruction mode; controlled aliasing in parallel imaging resulting in higher acceleration factors; acquisition time, 10.4 seconds) was repeated at 8 fixed time points within the 3 minutes after contrast agent injection. Image quality was evaluated on a 5-point scale (1, excellent; 5, nondiagnostic). Dynamic sequences were classified according to perfusion phases and contrast characteristics. Artifacts and position of the liver in the z axis were recorded and analyzed. RESULTS: Overall image quality was found to be 1.44 (95% confidence interval, 1.18-1.71). Contrast was scored as excellent in 25 of 27 patients for central vessels and 22 of 27 patients for peripheral vessels. Adequate-quality arterial-phase images were obtained in all 27 patients. Double arterial and single arterial phases were acquired in 13 of 27 and 14 of 27 patients (n = 6 arterial dominant, n = 8 early arterial phases), respectively. In 1 (3.7%) of 27 patients, severe respiratory artifacts were seen during an early arterial phase. Artifacts were observed in 21 of 27 patients and rated as mild in 19 of these. Compromised quality was related to receiver coils (17 of 29), parallel imaging (6 of 29), breathing (3 of 29), and other causes (3 of 29). The position of the liver throughout the dynamic phases was highly constant, with a greatest mean shift of +2.9 mm throughout the first dynamic acquisition. CONCLUSIONS: Advanced parallel acquisition with rhythmic breath-hold and gadoxetate injection allows arterial phase imaging without breathing artifacts; a decelerated yet normal breathing pattern results in very robust breath-hold depth.


Subject(s)
Breath Holding , Contrast Media , Gadolinium DTPA , Liver Neoplasms/diagnosis , Magnetic Resonance Imaging/methods , Adult , Aged , Female , Humans , Male , Middle Aged , Prospective Studies , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...