Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
Add more filters











Type of study
Publication year range
1.
Br Dent J ; 218(1): 9-12, 2015 Jan.
Article in English | MEDLINE | ID: mdl-25571813

ABSTRACT

This paper re-visits the need for patients or their carers to maintain as low a level of denture biofilm as possible. It notes that the handling of dentures is unpleasant to carers and suggests a method of reducing this contact to a minimum but yet allow efficient cleaning by means of brushing. It also highlights the potential damage that can occur due to mishandling or accident. The denture box acts as a safe storage unit and finally, it suggests that its 'footprint' allows accurate recovery in an institution where dentures can be inadvertently mingled.


Subject(s)
Dentures , Oral Hygiene/instrumentation , Biofilms , Dentures/adverse effects , Dentures/microbiology , Humans , Oral Hygiene/methods
2.
Br Dent J ; 214(10): 519-23, 2013 May.
Article in English | MEDLINE | ID: mdl-23703184

ABSTRACT

OBJECTIVE: To ascertain from participants of the BDJ UCL Eastman CPD programme its value to their professional endeavours, and in particular to determine whether they would object to making it more robust especially in the way that the CPD hours are achieved. DESIGN: An online questionnaire survey. METHOD: Participants were encouraged to complete an online survey of nine questions by 31 July 2012. RESULTS: Of the 3,292 participants who began the survey, it was completed by 3,070 (93.2%). Of those, 2,952 (91.1%) thought that additional learning tools would be helpful. The ability to resubmit incorrect answers was preferred by 2,549 (80.1%) of the respondents. Two thousand two hundred and fourteen participants (69.9%) raised no objection to making the scoring system more robust and 953 (30.1%) objections to this proposition were recorded. Ninety-eight percent (3,128) favoured the regular inclusion and flagging of core subjects and 95% of these respondents thought it would be useful to record these separately. The most preferred method of obtaining verifiable CPD was cited by 1,075 (39.5%) participants as reading journals followed by attending lectures and hands-on courses. The BDJ was the preferred journal to achieve both verifiable and general CPD. Most participants (1,930; 67.7%) use a home computer to take part in this initiative while a significant minority use tablets and smart-phones. CONCLUSION: This survey showed that the BDJ UCL Eastman CPD journal-based verifiable CPD programme remains a popular method of fulfilling the GDC regulations and that the majority of participants are in favour of making the process more rigorous.


Subject(s)
Data Collection , Education, Dental, Continuing , Attitude of Health Personnel , Data Collection/methods , Education, Dental, Continuing/methods , Humans , Online Systems , Schools, Dental , Surveys and Questionnaires , United Kingdom
4.
Br Dent J ; 199(10): 665-9, discussion 654, 2005 Nov 26.
Article in English | MEDLINE | ID: mdl-16311570

ABSTRACT

OBJECTIVE: There is little information available on journal based verifiable continuing professional development (CPD). The aim of this study was to survey those dentists who have undertaken this form of CPD and elicit their views. DESIGN: A questionnaire survey. METHOD: Four hundred dentists who had registered to undertake CPD with the British Dental Journal (BDJ) were randomly selected and sent a questionnaire. RESULTS: Three hundred and twelve questionnaires were returned (78%) of these 181 (58%) were male and 131 (42%) were female. Of the 312, 307 had undertaken the BDJ CPD initiative. Two hundred and sixty eight respondents (87.3%) agreed/strongly agreed that the BDJ CPD satisfied their personal CPD needs. Two hundred and eighty three (92.2%) agreed/strongly agreed that their knowledge has been increased as a result of undertaking the BDJ CPD initiative. Two hundred and twenty agreed/strongly agreed (71.7%) that an element of their clinical practice had changed as a result of undertaking the BDJ CPD initiative. CONCLUSION: Journal based learning appears to be an effective way of undertaking verifiable CPD.


Subject(s)
Education, Dental, Continuing/methods , Periodicals as Topic , Adult , Aged , Chi-Square Distribution , Female , Humans , Male , Middle Aged , Personal Satisfaction , Surveys and Questionnaires , United Kingdom
5.
Br Dent J ; 189(6): 318-22, 2000 Sep 23.
Article in English | MEDLINE | ID: mdl-11060953

ABSTRACT

OBJECTIVE: The aim of this study was to test whether rest seats cut by a group of general dental practitioners for a removable partial denture differed in size and shape from those prepared by either a group of postgraduate students or their academic teachers. METHOD: The occlusal surfaces of a number of plastic teeth were scanned by a laser profilometer. Each tooth was then placed in a set of articulated phantom head dental arches. 30 dental practitioners, 16 postgraduates and 11 dental academics were asked to cut a rest seat preparation in the mesial marginal ridge suitable for the construction of a removable chromium cobalt partial denture. The tooth was removed from the models, rescanned, and this data converted to grey level images for measurement of the width, length and area of each rest seat. Depth was calculated as the difference between the pre and post preparation scanned profiles. RESULTS: There was a wide variation in the size of the individual rest seat preparations. There was no significant difference between the measured parameters from the images of the preparations made by academic staff and postgraduate students. The two sets of data were therefore combined. The length, width and area of the rest seats prepared by the staff and postgraduate group were significantly greater than those cut by the dental practitioner group. However, there was no significant difference in the depths measured. The outline form of the rests prepared by the dental practitioners was often round with sharply defined margins contrasting with the smooth triangular preparation the staff and postgraduates prepared. CONCLUSION: A 'refresher' in tooth modification for GDPs designing partial dentures would improve the long term success of the prosthesis.


Subject(s)
Denture, Partial, Removable , Prosthodontics/education , Tooth Preparation, Prosthodontic/methods , Clinical Competence , Denture Retention/methods , Faculty, Dental , General Practice, Dental/education , Humans , Models, Dental , Molar , Students, Dental
6.
Int J Prosthodont ; 4(6): 539-42, 1991.
Article in English | MEDLINE | ID: mdl-1817525

ABSTRACT

The design of removable partial dentures has progressed both clinically and in laboratory research. Nonetheless, there still appears to be a conflict between the empirical practice and the scientific data available. On this basis, the authors question several aspects of the lingual connector. If lingual connectors are required to be rigid, how is this best achieved and can it be assured that designs impart sufficient rigidity? On the contrary, is it possible to make the connector too rigid? No conclusions are attempted in this theoretical discussion, but research to resolve the dilemma is encouraged.


Subject(s)
Denture Design , Denture, Partial, Removable , Humans , Mandible/physiology , Periodontal Ligament/physiology
7.
Clin Mater ; 6(2): 163-79, 1990.
Article in English | MEDLINE | ID: mdl-10147518

ABSTRACT

This study investigated the rigidity imparted by the dimensions and cross-sectional shape of major connectors for a range of arch-forms. Sixteen cobalt chromium castings in all were fabricated, four in the form of standardised lingual bars, four as thickened lingual bars, four as lingual plates and two as modified sublingual bars. Arch-forms varied in length, radius of curvature and mid-sagittal angulation. All connectors were tested in compression on an Instron machine with and without a resilient base. The latter simulated the displacement of the periodontal membrane. A further apparatus was constructed to record the transmission of applied loads to the contralateral side of the arch; again resilient material was used as an analogue to the periodontal ligament. Results indicated that connector deflection varied directly with its length and inversely with its radius of curvature and the minimum cross-section of the anterior third. A 20 degrees change in mid-sagittal angulation was not significant. The theoretical relationships between a connector's dimensions and its rigidity were not confirmed. Regions of minimum connector dimension limited rigidity. The lingual bars and plates did not distribute lateral stresses effectively to the contralateral side of the arch and were found to be less rigid than the modified sublingual bars.


Subject(s)
Denture Design/methods , Denture, Partial, Removable , Chromium Alloys , Humans , Materials Testing , Models, Biological , Stress, Mechanical
10.
11.
Dent Pract Dent Rec ; 16(6): 214-6, 1966 Feb.
Article in English | MEDLINE | ID: mdl-5218031
12.
Apex ; 2(4): 21-2, 1966.
Article in English | MEDLINE | ID: mdl-5233171
SELECTION OF CITATIONS
SEARCH DETAIL