Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 20
Filter
Add more filters










Publication year range
1.
Phys Rev Lett ; 124(23): 232502, 2020 Jun 12.
Article in English | MEDLINE | ID: mdl-32603173

ABSTRACT

We report on a comparison between the theoretically predicted and experimentally measured spectra of the first-forbidden nonunique ß-decay transition ^{137}Xe(7/2^{-})→^{137}Cs(7/2^{+}). The experimental data were acquired by the EXO-200 experiment during a deployment of an AmBe neutron source. The ultralow background environment of EXO-200, together with dedicated source deployment and analysis procedures, allowed for collection of a pure sample of the decays, with an estimated signal to background ratio of more than 99 to 1 in the energy range from 1075 to 4175 keV. In addition to providing a rare and accurate measurement of the first-forbidden nonunique ß-decay shape, this work constitutes a novel test of the calculated electron spectral shapes in the context of the reactor antineutrino anomaly and spectral bump.

2.
Phys Rev Lett ; 123(16): 161802, 2019 Oct 18.
Article in English | MEDLINE | ID: mdl-31702371

ABSTRACT

A search for neutrinoless double-ß decay (0νßß) in ^{136}Xe is performed with the full EXO-200 dataset using a deep neural network to discriminate between 0νßß and background events. Relative to previous analyses, the signal detection efficiency has been raised from 80.8% to 96.4±3.0%, and the energy resolution of the detector at the Q value of ^{136}Xe 0νßß has been improved from σ/E=1.23% to 1.15±0.02% with the upgraded detector. Accounting for the new data, the median 90% confidence level 0νßß half-life sensitivity for this analysis is 5.0×10^{25} yr with a total ^{136}Xe exposure of 234.1 kg yr. No statistically significant evidence for 0νßß is observed, leading to a lower limit on the 0νßß half-life of 3.5×10^{25} yr at the 90% confidence level.

3.
Phys Rev Lett ; 120(7): 072701, 2018 Feb 16.
Article in English | MEDLINE | ID: mdl-29542972

ABSTRACT

Results from a search for neutrinoless double-beta decay (0νßß) of ^{136}Xe are presented using the first year of data taken with the upgraded EXO-200 detector. Relative to previous searches by EXO-200, the energy resolution of the detector has been improved to σ/E=1.23%, the electric field in the drift region has been raised by 50%, and a system to suppress radon in the volume between the cryostat and lead shielding has been implemented. In addition, analysis techniques that improve topological discrimination between 0νßß and background events have been developed. Incorporating these hardware and analysis improvements, the median 90% confidence level 0νßß half-life sensitivity after combining with the full data set acquired before the upgrade has increased twofold to 3.7×10^{25} yr. No statistically significant evidence for 0νßß is observed, leading to a lower limit on the 0νßß half-life of 1.8×10^{25} yr at the 90% confidence level.

4.
Rev Sci Instrum ; 85(9): 095114, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25273779

ABSTRACT

We describe a system to transport and identify barium ions produced in liquid xenon, as part of R&D towards the second phase of a double beta decay experiment, nEXO. The goal is to identify the Ba ion resulting from an extremely rare nuclear decay of the isotope (136)Xe, hence providing a confirmation of the occurrence of the decay. This is achieved through Resonance Ionization Spectroscopy (RIS). In the test setup described here, Ba ions can be produced in liquid xenon or vacuum and collected on a clean substrate. This substrate is then removed to an analysis chamber under vacuum, where laser-induced thermal desorption and RIS are used with time-of-flight mass spectroscopy for positive identification of the barium decay product.

5.
Phys Rev Lett ; 109(3): 032505, 2012 Jul 20.
Article in English | MEDLINE | ID: mdl-22861843

ABSTRACT

We report on a search for neutrinoless double-beta decay of 136Xe with EXO-200. No signal is observed for an exposure of 32.5 kg yr, with a background of ∼1.5×10(-3) kg(-1) yr(-1) keV(-1) in the ±1σ region of interest. This sets a lower limit on the half-life of the neutrinoless double-beta decay T(1/2)(0νßß)(136Xe)>1.6×10(25) yr (90% C.L.), corresponding to effective Majorana masses of less than 140-380 meV, depending on the matrix element calculation.

6.
Phys Rev Lett ; 107(21): 212501, 2011 Nov 18.
Article in English | MEDLINE | ID: mdl-22181874

ABSTRACT

We report the observation of two-neutrino double-beta decay in (136)Xe with T(1/2) = 2.11 ± 0.04(stat) ± 0.21(syst) × 10(21) yr. This second-order process, predicted by the standard model, has been observed for several nuclei but not for (136)Xe. The observed decay rate provides new input to matrix element calculations and to the search for the more interesting neutrinoless double-beta decay, the most sensitive probe for the existence of Majorana particles and the measurement of the neutrino mass scale.

7.
Rev Sci Instrum ; 82(10): 105114, 2011 Oct.
Article in English | MEDLINE | ID: mdl-22047336

ABSTRACT

A magnetically driven piston pump for xenon gas recirculation is presented. The pump is designed to satisfy extreme purity and containment requirements, as is appropriate for the recirculation of isotopically enriched xenon through the purification system and large liquid xenon time projection chamber of EXO-200. The pump, using sprung polymer gaskets, is capable of pumping more than 16 standard liters per minute of xenon gas with 750 Torr differential pressure.

8.
Rev Sci Instrum ; 81(11): 113301, 2010 Nov.
Article in English | MEDLINE | ID: mdl-21133463

ABSTRACT

We describe a source capable of producing single barium ions through nuclear recoils in radioactive decay. The source is fabricated by electroplating (148)Gd onto a silicon α-particle detector and vapor depositing a layer of BaF(2) over it. (144)Sm recoils from the alpha decay of (148)Gd are used to dislodge Ba(+) ions from the BaF(2) layer and emit them in the surrounding environment. The simultaneous detection of an α particle in the substrate detector allows for tagging of the nuclear decay and of the Ba(+) emission. The source is simple, durable, and can be manipulated and used in different environments. We discuss the fabrication process, which can be easily adapted to emit most other chemical species, and the performance of the source.

9.
Opt Lett ; 8(6): 322-3, 1983 Jun 01.
Article in English | MEDLINE | ID: mdl-19718101

ABSTRACT

Absolute wave-number measurements, with an accuracy of 2-11 parts in 10(9), are presented for 27 (127)I(2) hyperfine-structure lines in the range 5763-6563 A. Individual components were resolved by saturation spectroscopy and their wave numbers measured by a comparison with wavelength standards made using a temperature-stabilized Fabry-Perot interferometer. Good consistency is found among the four accepted (127)I(2)wavelength standards. The result of a previous measurement at 6563 A, which was used as the basis for a Rydberg-constant determination, is also confirmed.

10.
Med Phys ; 7(4): 307-14, 1980.
Article in English | MEDLINE | ID: mdl-7393157

ABSTRACT

The magnetic susceptibility of the heart and the intracardiac blood is substantially greater than that of the surrounding lung tissue. The periodic redistribution of blood and tissue during the cardiac cycle will thus alter an externally applied magnetic field. These magnetic field changes can be detected by a magnetometer outside the body, and have been termed magnetic susceptibility plethysmography (MSPG) signals. A differential magnetometer, a liquid helium dewar, and a superconducting persistent-current magnet have been developed to detect the x component of the MSPG signal. The theoretical analysis of this instrument is presented to understand the spatial sensitivity of an MSPG susceptometer with a nonuniform magnetizing field. Preliminary measurements are shown to be in fair agreement with the model calculations. Several possible improvements of the technique are discussed.


Subject(s)
Cardiography, Impedance , Magnetics , Plethysmography, Impedance , Adult , Cardiography, Impedance/instrumentation , Humans , Male , Plethysmography, Impedance/instrumentation
11.
Opt Lett ; 5(11): 459-61, 1980 Nov 01.
Article in English | MEDLINE | ID: mdl-19701270

ABSTRACT

Single atoms are detected and their motion measured for the first time to our knowledge by the fluorescence photon- burst method in the presence of large quantities of buffer gas. A single-clipped digital correlator records the photon burst in real time and displays the atom's transit time across the laser beam. A comparison is made of the special requirements for single-atom detection in vacuum and in a buffer gas. Finally, the probability distribution of the bursts from many atoms is measured. It further proves that the bursts observed on resonance are due to single atoms and pot simply to noise fluctuations.

12.
Opt Lett ; 2(2): 30, 1978 Feb 01.
Article in English | MEDLINE | ID: mdl-19680396
13.
Science ; 198(4322): 1159-62, 1977 Dec 16.
Article in English | MEDLINE | ID: mdl-929192

ABSTRACT

A unipositional lead system has been developed to record the human magnetic heart vector and to permit comparison with the electric heart vector recorded with a conventional Frank lead system. Recordings made in five normal subjects showed a remarkably consistent relation between the electric and magnetic heart vectors. However, the angle between electric heart vector R and T waves was markedly different from the magnetic heart vector R-T angle. In addition, recordings made in two patients with bundle branch block showed a different relation between the electric and magnetic heart vectors compared to normal subjects. These data support the hypothesis that magnetic measurements have a different sensitivity to some components of cardiac activation compared with body surface potential measurements.


Subject(s)
Heart Block/physiopathology , Heart/physiology , Magnetics , Electrocardiography , Heart/physiopathology , Humans
15.
Science ; 196(4293): 973, 1977 May 27.
Article in English | MEDLINE | ID: mdl-17778708
20.
Appl Opt ; 10(10): 2259-62, 1971 Oct 01.
Article in English | MEDLINE | ID: mdl-20111312

ABSTRACT

A spectrograph using an image orthicon tube for low light level spectroscopy has been constructed. It has been tested for rapid raman spectroscopy and, with computer control, for transient absorption spectra of ions excited to metastable states. The advantages and disadvantages of the instrument are discussed.

SELECTION OF CITATIONS
SEARCH DETAIL
...