Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
J Pharm Biomed Anal ; 54(4): 826-9, 2011 Mar 25.
Article in English | MEDLINE | ID: mdl-21131157

ABSTRACT

The option, for practical and ethical reasons, to replace animal plasma with human plasma for calibration standards was successfully applied to 73 analytical methods developed in our laboratory during the last years. The animals used for obtaining blank plasma could then be reduced with a number corresponding to about 25% of mice or 5% of rats in ordinary one-month toxicology studies. This is of important public concern and also in accordance with the 3R-strategy. The methods were successfully validated for determination of drug concentrations in plasma from rat, dog, mouse, rabbit and cynomolgus monkey. Reproducibility of study samples from dosed animals was established, showing a mean accuracy of 100.8% with a CV of 7.2% (n=1339). The purpose of this paper is to present a scientific basis for the alternative approach to adopt human plasma matrix for calibration standards, which will reduce animal use, without compromising the quality of appropriately validated assays. Additional advantages are cheaper and simplified plasma maintenance and the possibility to validate methods for several species in the same analytical batch.


Subject(s)
Animal Testing Alternatives , Drug Evaluation, Preclinical/methods , Drugs, Investigational/analysis , Pharmaceutical Preparations/blood , Animals , Calibration , Chromatography, High Pressure Liquid , Drug Evaluation, Preclinical/economics , Drug Stability , Humans , Reproducibility of Results , Spectrometry, Mass, Electrospray Ionization , Tandem Mass Spectrometry , Toxicity Tests/economics , Toxicity Tests/methods
2.
J Pharm Biomed Anal ; 40(3): 794-8, 2006 Feb 24.
Article in English | MEDLINE | ID: mdl-16242284

ABSTRACT

In the course of development and validation of a gas chromatography-mass spectrometry (GC-MS) method for ramipril and its biologically active metabolite ramiprilat, evidence was found for an unknown interfering metabolite. Sample treatment included isolation from plasma or urine by solid-phase extraction, methylation with trimethylsilyldiazomethane and acylation with trifluoroacetic anhydride (TFAA). When liquid chromatography was used to fractionate plasma extracts prior to derivatization, the alkyl, acyl-derivative of ramipril was obtained from two separate LC fractions. Electrospray ionization mass spectral data, together with circumstances for the derivatization, were consistent with the presence of an N-glucuronide of ramipril. Interference from the metabolite was eliminated by including a wash step after extraction/alkylation, prior to acylation. The final assay had a lower limit of quantification at 1.0 nmol/L and a linear range of 1-300 nmol/L. Intra- and inter-batch precision for ramipril and ramiprilat in plasma or urine were better than 10 and 5% at 2 and 80 nmol/L, respectively.


Subject(s)
Angiotensin-Converting Enzyme Inhibitors/blood , Angiotensin-Converting Enzyme Inhibitors/urine , Ramipril/analogs & derivatives , Calibration , Gas Chromatography-Mass Spectrometry , Glucuronides/blood , Glucuronides/urine , Humans , Indicators and Reagents , Mass Spectrometry , Methylation , Ramipril/blood , Ramipril/urine , Reference Standards , Reproducibility of Results
3.
Article in English | MEDLINE | ID: mdl-12482476

ABSTRACT

Analytical methods for the determination of ximelagatran, an oral direct thrombin inhibitor, its active metabolite melagatran, and intermediate metabolites, melagatran hydroxyamidine and melagatran ethyl ester, in biological samples by liquid chromatography (LC) positive electrospray ionization mass spectrometry (MS) using selected reaction monitoring are described. Isolation from human plasma was achieved by solid-phase extraction on octylsilica. Analytes and isotope-labelled internal standards were separated by LC utilising a C(18) analytical column and a mobile phase comprising acetonitrile-4 mmol/l ammonium acetate (35:65, v/v) containing 0.1% formic acid, at a flow-rate of 0.75 ml/min. Absolute recovery was approximately 80% for ximelagatran, approximately 60% for melagatran ethyl ester and >90% for melagatran and melagatran hydroxyamidine. Limit of quantification was 10 nmol/l, with a relative standard deviation <20% for each analyte and <5% above 100 nmol/l. Procedures for determination of these analytes in human urine and breast milk, plus whole blood from rat and mouse are also described.


Subject(s)
Antithrombins/analysis , Azetidines/analysis , Chromatography, Liquid/methods , Glycine/analogs & derivatives , Glycine/analysis , Spectrometry, Mass, Electrospray Ionization/methods , Animals , Antithrombins/metabolism , Antithrombins/urine , Azetidines/blood , Azetidines/urine , Benzylamines , Glycine/blood , Glycine/urine , Humans , Mice , Milk, Human/chemistry , Rats , Reproducibility of Results , Sensitivity and Specificity