Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 200
Filter
1.
Clin Res Cardiol ; 2023 Dec 20.
Article in English | MEDLINE | ID: mdl-38117299

ABSTRACT

BACKGROUND: Anxiety and limited patient comprehension may pose significant barriers when informing elderly patients about complex procedures such as transcatheter aortic valve implantation (TAVI). OBJECTIVES: We aimed to evaluate the utility of medical graphics to improve the patient informed consent (IC) before TAVI. METHODS: In this prospective, randomized dual center study, 301 patients were assigned to a patient brochure containing medical graphics (Comic group, n = 153) or sham information (Control group, n = 148) on top of usual IC. Primary outcomes were patient understanding of central IC-related aspects and periprocedural anxiety assessed by the validated Spielberger State Trait Anxiety Inventory (STAI), both analyzed by cognitive status according to the Montreal Cognitive Assessment (MoCA). RESULTS: Patient understanding was significantly higher in the Comic group [mean number of correct answers 12.8 (SD 1.2) vs. 11.3 (1.8); mean difference 1.5 (95% CI 1.2-1.8); p < 0.001]. This effect was more pronounced in the presence of cognitive dysfunction (MoCA < 26) [12.6 (1.2) in the Comic vs. 10.9 (1.6) in the Control group; mean difference 1.8 (1.4-2.2), p < 0.001]. Mean STAI score declined by 5.7 (95% CI 5.1-6.3; p < 0.001) in the Comic and 0.8 points (0.2-1.4; p = 0.015) in the Control group. Finally, mean STAI score decreased in the Comic group by 4.7 (3.8-5.6) in cognitively impaired patients and by 6.6 (95% CI 5.8 to 7.5) in patients with normal cognitive function (p < 0.001 each). CONCLUSIONS: Our results prove beneficial effects for using medical graphics to inform elderly patients about TAVI by improving patient understanding and reducing periprocedural anxiety (DRKS00021661; 23/Oct/2020). Medical graphics entailed significant beneficial effects on the primary endpoints, patient understanding and periprocedural anxiety, compared to the usual patient informed consent (IC) procedure. Patient understanding of IC-related aspects was significantly higher in the Comic group, with a more pronounced benefit in patients with cognitive impairment (p for IC method and cognitive status < 0.001, respectively; p for IC method x MoCA category interaction = 0.017). There further was a significant decline of periprocedural anxiety in patients with and without cognitive impairment (p for IC method x measuring time point < 0.001; p for IC method x MoCA category x measuring time point interaction = 0.018).

2.
J Heart Lung Transplant ; 41(6): 810-817, 2022 06.
Article in English | MEDLINE | ID: mdl-35422347

ABSTRACT

BACKGROUND: The majority (89%) of left ventricular assist device (LVAD) patients have an implantable cardioverter-defibrillator (ICD) in place. Due to the advances of modern-day LVAD therapy, more patients are on support for longer. This inevitably leads to more LVAD patients facing ICD generator battery depletion. Until now, there are insufficient data regarding periprocedural risks of generator replacements in a high-risk group like the LVAD cohort. METHODS: A retrospective, single-center analysis of pocket-related outcomes of all ICD generator replacements in LVAD and Non-LVAD patients between January 2014 and December 2018. The primary outcome was the combined endpoint of clinically significant pocket hematoma and/or cardiac implantable electronic device (CIED) infection in the first 6 months after ICD generator exchange. The clinically significant hematoma was defined as hematoma requiring reoperation, prolongation of hospitalization, or interruption of anticoagulation. The cumulative incidence function was calculated for the primary endpoint. RESULTS: Two hundred seventy-seven patients underwent ICD generator exchange in our clinic in this time. Of these, 251 patients had a complete 6-month follow-up regarding clinically significant pocket hematomas and pocket infections. One hundred ninety patients had no LVAD, and 61 patients were on LVAD support. The rate of the primary combined endpoint clinically significant pocket hematoma and/or CIED infection was 3.5 times higher in LVAD patients compared to the non-LVAD cohort (event rate 39.14 vs 11.07 per 100 patient-years, p = 0.048). Clinically significant pocket hematomas necessitating revision occurred nearly 4 times more often in the LVAD group (p = 0.042). Pocket device infection rates were around 16 times higher in LVAD patients compared to non-LVAD patients (p = 0.002). CONCLUSIONS: Compared to Non-LVAD patients, LVAD patients exhibit a relevant higher rate of clinically significant pocket hematoma and CIED infection after ICD generator exchange. This information should additionally be considered in the decision-making process regarding the indication for ICD generator exchange.


Subject(s)
Defibrillators, Implantable , Heart Failure , Heart-Assist Devices , Defibrillators, Implantable/adverse effects , Heart Failure/therapy , Heart-Assist Devices/adverse effects , Hematoma/epidemiology , Hematoma/etiology , Humans , Retrospective Studies
3.
Int J Pharm ; 604: 120747, 2021 Jul 15.
Article in English | MEDLINE | ID: mdl-34051320

ABSTRACT

Granular materials are part of the design, production and final products of different industrial sectors. Powder flowability is a major topic in manufacturing and transport as it is closely related to process feasibility. Nonetheless, the flows of granular materials are not easy to describe or quantify, even in the simple case of dry monodisperse cohesionless particles. Flowability assessment is not a standard or normalized issue; still, no test is able predict powder flow behavior in all the different mechanical situations encountered during processing. This study aims (1) to evaluate flowability, as device-related, through the force or the energy supplied to the powder bed and (2) to study the effect of glidants and moisture content on flowability. To illustrate these aims, the flowability of two well-known pharmaceutical excipients, Avicel® PH-102 and Retalac® mixed with four different types of precipitated nano-silica (SIPERNAT® D10, D17, 50 S and 500 LS), was assessed using two granular compaction devices: Densitap® and FT4® compaction cell. Our results show that the hydrophilicity of colloidal silica affects surface coverage, ranging from 6% to over 80%. Binary mixtures with hydrophobic additives, D10 and D17, generated smaller silica aggregates with a wider spread on the surface of host particles. For Retalac® conditioned at 20% RH, HR values changed from 1.30 (acceptable flow) to 1.17 (good flow). For Avicel® PH-102, conditioned at 60% RH, HR values changed from 1.22 (fair flow) to less than 1.10 (excellent flow).


Subject(s)
Cellulose , Excipients , Humidity , Particle Size , Powders
4.
J Cardiovasc Magn Reson ; 23(1): 15, 2021 03 01.
Article in English | MEDLINE | ID: mdl-33641670

ABSTRACT

BACKGROUND: Circulatory efficiency reflects the ratio between total left ventricular work and the work required for maintaining cardiovascular circulation. The effect of severe aortic valve stenosis (AS) and aortic valve replacement (AVR) on left ventricular/circulatory mechanical power and efficiency is not yet fully understood. We aimed to quantify left ventricular (LV) efficiency in patients with severe AS before and after surgical AVR. METHODS: Circulatory efficiency was computed from cardiovascular magnetic resonance (CMR) imaging derived volumetric data, echocardiographic and clinical data in patients with severe AS (n = 41) before and 4 months after AVR and in age and sex-matched healthy subjects (n = 10). RESULTS: In patients with AS circulatory efficiency was significantly decreased compared to healthy subjects (9 ± 3% vs 12 ± 2%; p = 0.004). There were significant negative correlations between circulatory efficiency and LV myocardial mass (r = - 0.591, p < 0.001), myocardial fibrosis volume (r = - 0.427, p = 0.015), end systolic volume (r = - 0.609, p < 0.001) and NT-proBNP (r = - 0.444, p = 0.009) and significant positive correlation between circulatory efficiency and LV ejection fraction (r = 0.704, p < 0.001). After AVR, circulatory efficiency increased significantly in the total cohort (9 ± 3 vs 13 ± 5%; p < 0.001). However, in 10/41 (24%) patients, circulatory efficiency remained below 10% after AVR and, thus, did not restore to normal values. These patients also showed less reduction in myocardial fibrosis volume compared to patients with restored circulatory efficiency after AVR. CONCLUSION: In our cohort, circulatory efficiency is reduced in patients with severe AS. In 76% of cases, AVR leads to normalization of circulatory efficiency. However, in 24% of patients, circulatory efficiency remained below normal values even after successful AVR. In these patients also less regression of myocardial fibrosis volume was seen. Trial Registration clinicaltrials.gov NCT03172338, June 1, 2017, retrospectively registered.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Heart Valve Prosthesis Implantation , Ventricular Function, Left , Aged , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/physiopathology , Case-Control Studies , Echocardiography, Doppler , Female , Fibrosis , Heart Valve Prosthesis , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Humans , Magnetic Resonance Imaging, Cine , Male , Middle Aged , Myocardium/pathology , Recovery of Function , Severity of Illness Index , Time Factors , Treatment Outcome , Ventricular Remodeling
5.
Anaesthesia ; 75(8): 1039-1049, 2020 08.
Article in English | MEDLINE | ID: mdl-32342498

ABSTRACT

In patients with pre-operative anaemia undergoing cardiac surgery, combination treatment with intravenous iron, subcutaneous erythropoietin alpha, vitamin B12 and oral folic acid reduces allogeneic blood product transfusions. It is unclear if certain types of anaemia particularly benefit from this treatment. We performed a post-hoc analysis of anaemic patients from a randomised trial on the 'Effect of ultra-short-term treatment of patients with iron deficiency or anaemia undergoing cardiac surgery'. We used linear regression analyses to examine the efficacy of a combination anaemia treatment compared with placebo on the following deficiencies, each representing a part of the combination treatment: ferritin and transferrin saturation; endogenous erythropoietin; holotranscobalamine; and folic acid in erythrocytes. Efficacy was defined as change in reticulocyte count from baseline to the first, third and fifth postoperative days and represented erythropoietic activity in the immediate peri-operative recovery phase. In all 253 anaemic patients, iron deficiency was the most common cause of anaemia. Treatment significantly increased reticulocyte count in all regression analyses on postoperative days 1, 3 and 5 (all p < 0.001). Baseline ferritin and endogenous erythropoietin were negatively associated with change in reticulocyte count on postoperative day 5, with an unstandardised regression coefficient B of -0.08 (95%CI -0.14 to -0.02) and -0.14 (95%CI -0.23 to -0.06), respectively. Quadruple anaemia treatment was effective regardless of the cause of anaemia and its effect manifested early in the peri-operative recovery phase. The more pronounced a deficiency was, the stronger the subsequent boost to erythropoiesis may have been.


Subject(s)
Anemia/drug therapy , Preoperative Care/methods , Administration, Intravenous , Aged , Aged, 80 and over , Anemia, Iron-Deficiency/drug therapy , Blood Transfusion/statistics & numerical data , Cardiac Surgical Procedures/methods , Double-Blind Method , Drug Therapy, Combination , Erythropoietin/administration & dosage , Erythropoietin/therapeutic use , Female , Folic Acid/administration & dosage , Folic Acid/therapeutic use , Hematinics/administration & dosage , Hematinics/therapeutic use , Humans , Iron/administration & dosage , Iron/therapeutic use , Male , Middle Aged , Postoperative Period , Reticulocyte Count , Vitamin B 12/administration & dosage , Vitamin B 12/therapeutic use , Vitamin B Complex/administration & dosage , Vitamin B Complex/therapeutic use
6.
Chirurg ; 91(3): 235-239, 2020 Mar.
Article in German | MEDLINE | ID: mdl-32144448

ABSTRACT

Less than 10 years ago a breakthrough was made in the world of computer science and artificial intelligence (AI) with the application of deep neural networks, which initially found little attention in medicine. In 2017 the first high-ranking publications on the medical application of AI were published. The potential of AI became known to many both in clinical medicine as well as in clinical and biomedical research. At the end of 2019 a phase of upheaval is occurring: first concepts for regulatory procedures have appeared, a large number of start-ups but also established companies are endeavoring to introduce AI-based medical devices into the market. This article discusses the basic principles for understanding AI-based medical devices as well as an overview of current AI-based solutions specific to cardiac surgery.


Subject(s)
Biomedical Research , Cardiac Surgical Procedures , Artificial Intelligence , Neural Networks, Computer
7.
Eur Heart J ; 41(2): 200-203, 2020 Jan 07.
Article in English | MEDLINE | ID: mdl-31909425
8.
Sci Rep ; 9(1): 3327, 2019 Feb 26.
Article in English | MEDLINE | ID: mdl-30804387

ABSTRACT

A correction to this article has been published and is linked from the HTML and PDF versions of this paper. The error has been fixed in the paper.

10.
Sci Rep ; 7(1): 9897, 2017 08 29.
Article in English | MEDLINE | ID: mdl-28851875

ABSTRACT

Optimizing treatment planning is essential for advances in patient care and outcomes. Precisely tailored therapy for each patient remains a yearned-for goal. Cardiovascular modelling has the potential to simulate and predict the functional response before the actual intervention is performed. The objective of this study was to proof the validity of model-based prediction of haemodynamic outcome after aortic valve replacement. In a prospective study design virtual (model-based) treatment of the valve and the surrounding vasculature were performed alongside the actual surgical procedure (control group). The resulting predictions of anatomic and haemodynamic outcome based on information from magnetic resonance imaging before the procedure were compared to post-operative imaging assessment of the surgical control group in ten patients. Predicted vs. post-operative peak velocities across the valve were comparable (2.97 ± 1.12 vs. 2.68 ± 0.67 m/s; p = 0.362). In wall shear stress (17.3 ± 12.3 Pa vs. 16.7 ± 16.84 Pa; p = 0.803) and secondary flow degree (0.44 ± 0.32 vs. 0.49 ± 0.23; p = 0.277) significant linear correlations (p < 0.001) were found between predicted and post-operative outcomes. Between groups blood flow patterns showed good agreement (helicity p = 0.852, vorticity p = 0.185, eccentricity p = 0.333). Model-based therapy planning is able to accurately predict post-operative haemodynamics after aortic valve replacement. These validated virtual treatment procedures open up promising opportunities for individually targeted interventions.

11.
Int J Cardiol ; 241: 326-329, 2017 Aug 15.
Article in English | MEDLINE | ID: mdl-28499667

ABSTRACT

BACKGROUND: Stanford acute type A aortic dissection (ATAAD) is a potentially lethal condition. Epidemiology studies show a statistical incidence in Europe of approximately 2-16 cases/100,000 inhabitants/year. In Germany, the estimated incidence (here subsumed under "thoracic aortic dissection" with 4.63 cases/100,000 inhabitants/year) is mainly extracted from medical death certificates by the German Federal Statistical Office. The prehospital incidence of ATAAD deaths is largely unknown. Since patients often die in the pre-hospital setting, the incidence of ATAAD is therefore likely to be higher than current estimates. MATERIAL AND METHODS: For the period from 2010 to 2014, we retrospectively analyzed all in-hospital ATAAD data from two of the largest cardiac surgical centers that treat ATAAD in the Berlin-Brandenburg region. In addition, autopsy reports of all forensic medicine institutes and of one large pathological provider in the region were analyzed to identify additional non-hospitalized ATAAD patients. Based on these findings, the regional incidence of ATAAD was calculated. RESULTS: In addition to in-hospital ATAAD patients (n=405), we identified additional 145 lethal ATAAD cases among 14,201 autopsy reports. The total of 550 ATAAD cases led to an estimated incidence of 11.9 cases/100,000 inhabitants/year for the whole Berlin-Brandenburg region. Arterial hypertension, pre-existing aortic dilatation, and hereditary connective tissue disorder were found in, respectively, 62.7%, 10%, and 1.8% of patients. CONCLUSION: ATAAD is more frequent than previously reported. Our results show that when patients who die outside of cardiac surgery centers are included, the incidence of ATAAD significantly exceeds the rate reported by the Federal Statistical Office.


Subject(s)
Aorta/pathology , Aortic Aneurysm/epidemiology , Aortic Aneurysm/pathology , Aortic Dissection/epidemiology , Aortic Dissection/pathology , Adult , Aged , Aged, 80 and over , Aortic Dissection/mortality , Aortic Aneurysm/mortality , Berlin/epidemiology , Female , Germany/epidemiology , Hospitalization/trends , Humans , Incidence , Male , Middle Aged , Retrospective Studies
12.
Chem Commun (Camb) ; 52(97): 14023-14026, 2016 Nov 29.
Article in English | MEDLINE | ID: mdl-27853758

ABSTRACT

Self-assembly of a molecule with many distinct conformational states, resulting in eight possible pairs of surface enantiomers, is investigated on a Au(111) surface under UHV conditions. The complex molecule is equipped with alkyl and carboxyl moieties to promote controlled self-assembly of lamellae structures. From statistical analysis of Scanning Tunnelling Microscopy (STM) data we observe a clear selection of specific conformational states after self-assembly. Using Density Functional Theory (DFT) calculations we rationalise how this selection is correlated to the orientation of the alkyl moieties in mirror-image domains of the lamellae structures, leading to selection of three out of the eight possible enantiomeric pairs.

15.
Eur Heart J ; 36(41): 2779, 2015 Nov 01.
Article in English | MEDLINE | ID: mdl-26129948

ABSTRACT

Corrigendum to: 2014 ESC Guidelines on the diagnosis and treatment of aortic diseases [Eur Heart Journal (2014) 35, 2873­2926,doi:10.1093/eurheartj/ehu281]. In Table 3, the radiation for MRI is "0" and not "-". The corrected table is shown below.

16.
Herz ; 40(2): 231-9, 2015 Apr.
Article in German | MEDLINE | ID: mdl-25822421

ABSTRACT

Mechanical circulatory support nowadays represents an important option in the treatment of patients with advanced heart insufficiency. Once developed as a bridging to heart transplantation, it is now a valuable option for permanent support in patients for whom a heart transplantation is not possible due to contraindications or a lack of available organs. Furthermore, it can be used as a bridging to myocardial recovery and explantation. The number of implantations of left ventricular assist devices (LVAD) has clearly increased in recent years and approximately one half of these implantations is already carried out in centers not specialized in transplantations. This development necessitates that every practicing physician is aware of the basic principles of mechanical circulatory support and with the possible complications. This article gives a summary of the current state of the technology and treatment of patients with long-term VADs.


Subject(s)
Heart Failure/prevention & control , Heart-Assist Devices , Infusion Pumps, Implantable , Terminal Care/methods , Ventricular Dysfunction, Left/therapy , Chronic Disease , Heart Failure/diagnosis , Heart Failure/etiology , Humans , Prosthesis Design , Treatment Outcome , Ventricular Dysfunction, Left/complications , Ventricular Dysfunction, Left/diagnosis
17.
Transplant Proc ; 46(5): 1463-8, 2014 Jun.
Article in English | MEDLINE | ID: mdl-24935314

ABSTRACT

INTRODUCTION: There are conflicting reports on the posttransplantation morbidity and mortality of patients listed urgently and/or supported by a ventricular assist device (VAD). The aim of this study was to analyze the outcomes with regard to pretransplantation condition (elective, urgent, VAD). METHODS: All adult recipients between January 1, 2005, and October 31, 2012, were included. Demographics; preoperative, operative, and postoperative data; outpatient follow-up; and donor characteristics were collected and analyzed. RESULTS: Of a total of 74 patients, 19 were listed urgently, 20 had a Berlin Heart EXCOR BVAD (biventricular assist device) (Berlin Heart, Berlin, Germany) (8 urgent), 7 had a Berlin Heart INCOR left VAD (Berlin Heart, Berlin, Germany) (2 urgent), and 2 had a HeartWare left VAD (HeartWare International, Framingham, Mass, USA) (none urgent). Mean age was 52 ± 12years. The overall 30-day, 1-year, and 3-year survival was 90% ± 3%, 79% ± 5%, and 66% ± 7%. There was no difference in survival when comparing urgently listed (95% ± 5%, 84% ± 8%, 74% ± 12%) and elective patients (89% ± 4%, 77% ± 6%, 63% ± 8%; P = .4), and VAD patients (86% ± 6%, 76% ± 8%, 63% ± 11%) and those without mechanical support (93% ± 4%, 81% ± 6%, 69% ± 9%; P = .6). In-hospital outcomes and long-term complications were also comparable. CONCLUSIONS: Our series suggests that urgent patients and patients on a VAD have a posttransplantation outcome comparable to elective patients and patients without a VAD. These data support the effectiveness of the current practice of listing for heart transplantation.


Subject(s)
Heart Transplantation , Heart-Assist Devices , Severity of Illness Index , Aged , Female , Humans , Male , Middle Aged , Survival Rate , Treatment Outcome
18.
Eur J Emerg Med ; 21(2): 105-11, 2014 Apr.
Article in English | MEDLINE | ID: mdl-23751288

ABSTRACT

OBJECTIVE: The use of emergency medical services increases with the age of patients. Some care providers hold on to the prejudice that these alarms are unnecessary or of a lower importance. We assessed the relation of age and age-dependent emergency characteristics, taking into consideration the ratings of emergency physicians on whether or not emergency cases were considered truly in need of emergency physician attendance. METHODS: Emergency physicians dispatched by the Berlin Fire Department evaluated for each case the necessity of emergency physician attendance. Case characteristics such as the day of the week and location of the emergency as well as patient characteristics such as age, sex, prior status, and care dependency were recorded. In addition, whether or not the physician accompanied the patient to the hospital was recorded as a parameter for emergency severity. Analysis was performed using multiple logistic regression modeling. RESULTS: During the 6-month prospective study period, 2702 cases were evaluated. Emergency medical services are used more frequently by older individuals, especially octogenarians. Emergency cases in older individuals were significantly more often rated as in need of emergency physician attendance; however, the rate of patients accompanied by the emergency physician to the hospital did not differ between the age groups. The age of patients, the primary diagnosis, the day and location of the emergency, and the presence of pre-existing dementia showed a significant impact on the necessity of physician-attended emergency missions. CONCLUSION: Despite common prejudices, emergency cases in elder patients are rated more often as in need of emergency physician attendance compared with those involving younger patients.


Subject(s)
Chronic Disease/therapy , Emergency Medical Services/organization & administration , Health Services for the Aged/organization & administration , Adolescent , Adult , Age Factors , Aged , Aged, 80 and over , Child , Child, Preschool , Emergencies , Emergency Medical Services/standards , Germany , Health Services for the Aged/standards , Humans , Infant , Middle Aged , Prospective Studies , Quality of Health Care , Surveys and Questionnaires , Young Adult
19.
Perfusion ; 28(4): 292-7, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23404056

ABSTRACT

BACKGROUND: In order to reduce the negative effects of extracorporeal circulation (ECC), the perfusion system and management were optimized at our institution. The goals of optimization were a reduction in the priming volume, in the foreign surface area and in microbubble activity, as well as optimization of suction blood management. METHODS: Sixty patients were included in this retrospective study. Patients were assigned to two groups, with regard to the use of an optimized perfusion system (OPS-group, n=30) and a standard perfusion system (SPS-group, n=30). All patients underwent elective procedures. RESULTS: There were no significant differences with respect to patient demographics and operation time. ECC time and cross-clamp time were significantly longer in the OPS group. Statistically significant differences in outcome between the two groups were seen with regard to the following variables: effective priming volume (OPS: 775±447ml; SPS: 1610±0ml; p<0.0001), hemoglobin drop after the start of ECC (OPS: 2.7±1.2g/dl; SPS: 4.2±0.8g/dl; p<0.0001), c-reactive protein on postoperative day 2 (OPS: 121.0±59.4 U/l; SPS: 164.0±50.2 U/l; p=0.003). With regard to the use of blood transfusions, a 33% reduction in the overall amount of transfused units was seen. The rate of patients without transfusions during the entire hospital stay increased from 37% (SPS) to 53% (OPS). The mean transfused red blood cell units per patient was lower in the OPS-group (1.6±2.4 units) than in the SPS-group (2.3±3.5 units). CONCLUSION: With the described optimized perfusion system, a significantly lower priming volume, leading to less hemodilution after the onset of CPB, was achieved. The amount of blood transfusions and the inflammatory response were reduced.


Subject(s)
Cardiopulmonary Bypass/methods , Extracorporeal Circulation/methods , Adult , Aged , Aged, 80 and over , Blood Transfusion , C-Reactive Protein/analysis , Cardiopulmonary Bypass/instrumentation , Extracorporeal Circulation/instrumentation , Female , Hemoglobins/analysis , Humans , Male , Middle Aged , Retrospective Studies
20.
Cardiology ; 123(4): 219-22, 2012.
Article in English | MEDLINE | ID: mdl-23208189

ABSTRACT

OBJECTIVES: Drug-related problems (DRPs) are events or circumstances involving drug therapy that actually or potentially interfere with desired health outcomes. This study tested the applicability of clinical decision support software in identifying and managing DRPs among cardiovascular surgery inpatients. METHODS: Two clinical pharmacologists attended ward rounds on a low-dependency cardiovascular surgery ward every 2 weeks over a 7-month period. Three hundred and three patients were assessed. On average, patients received 17 scheduled and 'as required' medicines. DRPs were identified 'manually' via assessment of electronic prescription charts and patient records and 'electronically' using clinical decision support software (Pharmavista). The numbers of alerts for optimizing medication safety generated by the two methods were compared. RESULTS: Manual checking identified 346 DRPs leading to 346 alerts in 201 patients (overall 1.1 alerts/patient). Relevant interactions accounted for 44% of DRPs detected by clinical pharmacologists. Clinical decision support software, which could only report interactions, however, generated 1,370 alerts (average 4.5 alerts/patient). Only 147 (11%) drug-drug interaction alerts were identical to those identified by manual checking; the remaining 89% were considered not clinically relevant. CONCLUSIONS: Compared to identification of DRPs by clinical pharmacologists, the clinical decision support software performed poorly due to over-alerting and inability to assess for problems not caused by drug-drug interactions.


Subject(s)
Decision Support Systems, Clinical , Drug Interactions , Software , Cardiovascular Surgical Procedures , Humans , Inpatients/statistics & numerical data , Pharmacology, Clinical/standards
SELECTION OF CITATIONS
SEARCH DETAIL
...