Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 130
Filter
1.
Article in English | MEDLINE | ID: mdl-38699843

ABSTRACT

BACKGROUND: Calcific mitral stenosis (calcific MS) presents a challenge for surgical treatment and is a contraindication for most contemporary transcatheter mitral valve replacement devices (TMVR), rendering patients with very limited therapeutic options. AIMS: This study aims to assess the clinical and hemodynamic follow-up after mitral valve lithotripsy (MVL). METHODS: All consecutive patients who underwent MVL to treat symptomatic calcific MS at St Michael's Hospital, Toronto, Canada, were included. Patients were deemed unsuitable for mitral surgery or TMVR after heart team assessment. Patients with rheumatic MS or ≥moderate mitral regurgitation (MR) were excluded. The primary endpoint was a reduction in the invasive mitral gradient by ≥50% without significant (≥moderate) MR. RESULTS: Fifteen patients underwent MVL between 2021 and 2023 with a mean age of 74 ± 9 years; 53% were female, with a mean STS score of 10% ± 0.1%. Following MVL, there was a reduction in the invasively measured mean trans-mitral gradient compared to baseline (14 mmHg vs. 6 mmHg; p < 0.05). The primary endpoint was achieved in 8 patients (53%) with no major procedural complications. At follow-up (median 90 days, IQR 58-115 days), 14 (93%) patients reported improved symptoms from New York Heart Association (NYHA) Class III-IV to NYHA Class I-II (p < 0.01) with stable echo-derived mean gradient (7.7 mmHg ± 2 mmHg vs. 8.4 mmHg ± 2.9 mmHg (p = 0.7). CONCLUSIONS: In selected patients with symptomatic inoperable calcific MS, MVL was safe and associated with significant short-term clinical and hemodynamic improvement. MVL may represent a new compassionate therapy for this challenging cohort. Further studies are needed to determine the long-term outcomes and help define the role of IVL technology in treating calcific valvular conditions.

2.
Article in English | MEDLINE | ID: mdl-38752971

ABSTRACT

BACKGROUND: The safety profile of transcatheter tricuspid valve (TTV) repair techniques is well established, but residual tricuspid regurgitation (TR) remains a concern. OBJECTIVES: The authors sought to assess the impact of residual TR severity post-TTV repair on survival. METHODS: We evaluated the survival rate at 2 years of 613 patients with severe isolated functional TR who underwent TTV repair in TRIGISTRY according to the severity of residual TR at discharge using a 3-grade (mild, moderate, and severe) or 4-grade scheme (mild, mild to moderate, moderate to severe, and severe). RESULTS: Residual TR was none/mild in 33%, moderate in 52%, and severe in 15%. The 2-year adjusted survival rates significantly differed between the 3 groups (85%, 70%, and 44%, respectively; restricted mean survival time [RMST]: P = 0.0001). When the 319 patients with moderate residual TR were subdivided into mild to moderate (n = 201, 33%) and moderate to severe (n = 118, 19%), the adjusted survival rate was also significantly different between groups (85%, 80%, 55%, and 44%, respectively; RMST: P = 0.001). Survival was significantly lower in patients with moderate to severe residual TR compared to patients with mild to moderate residual TR (P = 0.006). No difference in survival rates was observed between patients with no/mild and mild to moderate residual TR (P = 0.67) or between patients with moderate to severe and severe residual TR (P = 0.96). CONCLUSIONS: The moderate residual TR group was heterogeneous and encompassed patients with markedly different clinical outcomes. Refining TR grade classification with a more granular 4-grade scheme improved outcome prediction. Our results highlight the importance of achieving a mild to moderate or lower residual TR grade during TTV repair, which could define a successful intervention.

3.
Eur J Heart Fail ; 2024 Apr 12.
Article in English | MEDLINE | ID: mdl-38606485

ABSTRACT

AIMS: Patients with heart failure and mildly reduced or preserved ejection fraction have limited therapeutic options. The ALT-FLOW Early Feasibility Study evaluated safety, haemodynamics and outcomes for the APTURE transcatheter shunt system, a novel left atrium to coronary sinus shunt in these patients. METHODS AND RESULTS: Safety and shunt implantation success was evaluated for all 116 enrolled patients. An analysis population of implanted patients with a left ventricular ejection fraction (LVEF) >40% (n = 95) was chosen to assess efficacy via paired comparison between baseline and follow-up haemodynamic (3 and 6 months), and echocardiographic, clinical and functional outcomes (6 months and 1 year). Health status and quality of life outcomes were assessed using the Kansas City Cardiomyopathy Questionnaire overall summary score (KCCQ-OSS). The primary safety endpoint, major adverse cardiac, cerebral, and renal events, and reintervention through 30 days, occurred in 3/116 patients (2.6%). All implanted shunts were patent at 1 year. In patients with LVEF >40%, the mean (95% confidence interval) reduction in exercise pulmonary capillary wedge pressure (PCWP) at 20 W was -5.7 (-8.6, -2.9) mmHg at 6 months (p < 0.001). At baseline, 8% had New York Heart Association class I-II status and improved to 68% at 1 year (p < 0.001). KCCQ-OSS at baseline was 39 (35, 43) and improved at 6 months and 1 year by 25 (20-30) and 27 (22-32) points, respectively (both p < 0.0001). No adverse changes in haemodynamic and echocardiographic indices of right heart function were observed at 1 year. Overall, the reduction in PCWP at 20 W and improvement in KCCQ-OSS in multiple subgroups were consistent with those observed for the entire population. CONCLUSIONS: In patients with heart failure and LVEF >40%, the APTURE shunt demonstrated an acceptable safety profile with significant sustained improvements in haemodynamic and patient-centred outcomes, underscoring the need for further evaluation of the APTURE shunt in a randomized trial.

5.
JACC Cardiovasc Interv ; 17(7): 859-870, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38599688

ABSTRACT

BACKGROUND: Data on the prognostic role of the TRI-SCORE in patients undergoing transcatheter tricuspid valve intervention (TTVI) are limited. OBJECTIVES: The aim of this study was to evaluate the performance of the TRI-SCORE in predicting outcomes of patients undergoing TTVI. METHODS: TriValve (Transcatheter Tricuspid Valve Therapies) is a large multicenter multinational registry including patients undergoing TTVI. The TRI-SCORE is a risk model recently proposed to predict in-hospital mortality after tricuspid valve surgery. The TriValve population was stratified based on the TRI-SCORE tertiles. The outcomes of interest were all-cause death and all-cause death or heart failure hospitalization. Procedural complications and changes in NYHA functional class were also reported. RESULTS: Among the 634 patients included, 223 patients (35.2%) had a TRI-SCORE between 0 and 5, 221 (34.8%) had 6 or 7, and 190 (30%) had ≥8 points. Postprocedural blood transfusion, acute kidney injury, new atrial fibrillation, and in-hospital mortality were more frequent in the highest TRI-SCORE tertile. Postprocedure length of stay increased with a TRI-SCORE increase. A TRI-SCORE ≥8 was associated with an increased risk of 30-day all-cause mortality and all-cause mortality and the composite endpoint assessed at a median follow-up of 186 days (OR: 3.00; 95% CI: 1.38-6.55; HR: 2.17; 95% CI: 1.78-4.13; HR: 2.08, 95% CI: 1.57-2.74, respectively) even after adjustment for procedural success and EuroSCORE II or Society of Thoracic Surgeons Predicted Risk of Mortality. The NYHA functional class improved across all TRI-SCORE values. CONCLUSIONS: In the TriValve registry, the TRI-SCORE has a suboptimal performance in predicting clinical outcomes. However, a TRISCORE ≥8 is associated with an increased risk of clinical events and a lack of prognostic benefit after successful TTVI.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Cardiac Catheterization/methods , Heart Failure/diagnosis , Heart Failure/therapy , Heart Failure/etiology , Treatment Outcome , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Multicenter Studies as Topic , Registries
7.
Int J Cardiol ; 405: 131934, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38437953

ABSTRACT

AIMS: T-TEER is an effective therapy for the treatment of tricuspid regurgitation (TR). However, the effects of leaflets clipping on tricuspid valve annulus (TA) have not been investigated in detail. The aim of this study is to investigate the effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on TA diameter. METHODS AND RESULTS: The TriValve registry (Transcatheter Tricuspid Valve Therapies, NCT03416166) collected 556 patients from 22 European and North American centres undergoing transcatheter tricuspid valve interventions from 2016 to 2022. Patients undergoing T-TEER with available pre- and post-procedural data on TA diameter measured in the apical 4-chamber view on transthoracic echocardiography were selected for this study. Primary end-point was the reduction of TA diameter after T-TEER. A total of 186 patients were included in the study. In 115 patients (62%) TA diameter was reduced by at least 1 mm as compared to baseline. A significant reduction of TA dimension was observed following T-TEER (mean 2.3 mm [from pre-procedural diameter 46.7 mm to post-procedural diameter 44.4 mm], p < 0.001). In particular, the greatest reduction was observed in those with T-TEER in antero-septal commissure (mean 2.7 mm [from 47.1 mm to 44.4 mm], p < 0.001) as compared to those combining both antero-septal and postero-septal commissures (mean 1.4, from 46.0 mm to 44.6 mm, P = 0.06). A significant reduction of TA dimension was recorded in patients with 1 or 2 clips implanted but not in those patients with ≥3 clips implanted. CONCLUSIONS: In almost two third of patients T-TEER reduces TA diameter in addition to leaflet approximation. CONDENSED ABSTRACT: The effects of tricuspid transcatheter edge-to-edge repair (T-TEER) on tricuspid valve annulus (TA) have not been studied in details. This study investigates TA diameter as measured in apical 4-chamber view on transthoracic echocardiography before and after T-TEER. A total of 186 patients from the TriValve registry were included in the study. The study results show that 62% of patients have a TA reduction after T-TEER, especially in those receiving 1 or 2 clips in the antero-septal commissure. These suggest that T-TEER reduces tricuspid regurgitation not only by approximation of leaflets, but also by TA diameter reduction.


Subject(s)
Cardiac Catheterization , Registries , Tricuspid Valve Insufficiency , Tricuspid Valve , Humans , Male , Female , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Aged , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve Insufficiency/diagnostic imaging , Cardiac Catheterization/methods , Aged, 80 and over , Treatment Outcome , Heart Valve Prosthesis Implantation/methods , Middle Aged , Echocardiography/methods
8.
CJC Open ; 6(1): 47-53, 2024 Jan.
Article in English | MEDLINE | ID: mdl-38313339

ABSTRACT

Background: Despite advancements in critical care and coronary revascularization, cardiogenic shock (CS) outcomes remain poor. Implementing a shock team and use of veno-arterial extracorporeal membrane oxygenation (VA-ECMO) have been associated with improved CS outcomes, but its feasibility in remote and rural areas remains unknown. Methods: This retrospective study included patients with CS who required mechanical circulatory support (MCS) at Health Sciences North, Sudbury, Ontario. The analysis aimed to accomplish 2 objectives: first, to review the outcomes associated with use of Impella (Abiomed, Danvers, MA) and, second, to assess the feasibility of establishing a shock team to facilitate the local implementation of VA-ECMO. The primary endpoint was in-hospital mortality. Results: The outcomes of 15 patients with CS who received Impella between 2015 and 2021 were reviewed. Their average age was 65 years (standard deviation [SD]: 13), and 8 patients (53%) were female. CS was ischemic in 12 patients (80%). Transfemoral Impella CP (cardiac power) was the most frequently used (93%). Thirteen patients (87%) died during the index hospital stay post-Impella because of progressive circulatory failure. The shock team was established following consultations with several Canadian MCS centres, leading to the development of a protocol to guide use of MCS. There have been 4 cases in which percutaneous VA-ECMO using Cardiohelp (Getinge/Maquet, Wayne, NJ) has been used; 3 (75%) survived beyond the index hospitalization. Conclusions: This analysis demonstrated the feasibility of implementing a shock team in remote Northern Ontario, enabling the use of VA-ECMO with success in a centre with a sizeable rural catchment area. This initiative helps address the gap in cardiac care outcomes between rural and urban areas in Ontario.


Introduction: En dépit des avancées des soins aux patients en phase critique et de la revascularisation coronarienne, les résultats du choc cardiogénique (CC) semblent mauvais. La mise en place d'une équipe de choc et l'utilisation de l'oxygénation extracorporelle (ECMO, de l'anglais extracorporeal membrane oxygenation) par voie veino-artérielle (VA) (VA-ECMO) ont été associées à de meilleurs résultats du CC, mais on ignore sa faisabilité dans les régions éloignées et rurales. Méthodes: La présente étude rétrospective portait sur des patients en CC qui ont eu besoin d'une assistance circulatoire mécanique (ACM) à Horizon Santé-Nord, à Sudbury, en Ontario. L'analyse visait 2 objectifs : le premier objectif était de passer en revue les résultats associés à l'utilisation de Impella (Abiomed, Danvers, MA) et, le deuxième était d'évaluer la faisabilité de la mise en place d'une équipe de choc pour faciliter la mise en œuvre locale de la VA-ECMO. Le principal critère d'évaluation était la mortalité intrahospitalière. Résultats: Nous avons passé en revue les résultats cliniques de 15 patients ayant subi un CC qui avaient reçu une Impella entre 2015 et 2021. L'âge moyen était de 65 ans (écart type [ET] : 13), et 8 patients (53 %) étaient des femmes. Le CC était d'origine ischémique chez 12 patients (80 %). L'Impella CP (cardiac power, soit la pompe cardiaque) par voie transfémorale était la plus fréquemment utilisée (93 %). Treize patients (87 %) sont morts durant le séjour de référence à l'hôpital après l'utilisation de l'Impella en raison d'insuffisance circulatoire progressive. La mise en place de l'équipe de choc à la suite des consultations dans plusieurs centres canadiens d'ACM a mené à l'élaboration d'un protocole d'utilisation de l'ACM. Il y a eu 4 cas chez lesquels la VA-ECMO par voie percutanée à l'aide de Cardiohelp (Getinge/Maquet, Wayne, New Jersey, É.-U.) a été utilisée ; 3 (75 %) ont survécu après l'hospitalisation de référence. Conclusions: Cette analyse a démontré la faisabilité de la mise en place d'une équipe de choc dans les régions éloignées du nord de l'Ontario, qui a permis d'utiliser efficacement la VA-ECMO dans un centre d'une circonscription hospitalière rurale non négligeable. Cette initiative aide à remédier à l'écart des résultats en soins cardiaques entre les régions rurales et urbaines de l'Ontario.

10.
JACC Cardiovasc Interv ; 17(4): 552-560, 2024 Feb 26.
Article in English | MEDLINE | ID: mdl-38418058

ABSTRACT

BACKGROUND: Transcatheter tricuspid valve replacement (TTVR) abolishes tricuspid regurgitation (TR) and has emerged as a definitive treatment for TR. OBJECTIVES: The purpose of this multicenter, observational study was to determine the clinical characteristics and short-term outcomes of patients with TR screened for TTVR. METHODS: Patients underwent TTVR screening at 7 centers on a compassionate-use basis. The primary endpoints were NYHA functional class and TR grade at 30-day follow-up. Secondary endpoints included all-cause mortality, heart failure hospitalization, technical success, and reasons for TTVR screening failure. RESULTS: A total of 149 patients (median age 79 years [Q1-Q3: 72-84 years], 54% women) underwent TTVR screening. The TTVR screening failure rate was 74%, mainly related to large tricuspid annular diameter. Patients undergoing TTVR (n = 38) had significant functional improvements (NYHA functional class I or II from 21% to 68%; P < 0.001), with TR ≤1+ in 97% at 30-day follow-up (P < 0.001 from baseline). Technical success was achieved in 91%, with no intraprocedural mortality or conversion to surgery. At 30-day follow-up, mortality was 8%, heart failure hospitalization 5%, major bleeding 18%, and reintervention 9%. Patients who failed screening for TTVR and subsequently underwent "bailout" transcatheter edge-to-edge repair (n = 26) had favorable outcomes (NYHA functional class I or II from 27% to 58%; P < 0.001), with TR ≤1+ in 43% at 30-day follow-up (P < 0.001 from baseline). CONCLUSIONS: This first real-world report of TTVR screening demonstrated a high screening failure rate, mainly related to large tricuspid annular diameter. Patients undergoing TTVR had superior TR reduction and symptom alleviation compared with bailout tricuspid transcatheter edge-to-edge repair, at the cost of greater procedural complications.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Female , Aged , Male , Tricuspid Valve/diagnostic imaging , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/adverse effects , Hemodynamics , Cardiac Catheterization/adverse effects , Treatment Outcome , Recovery of Function , Time Factors , Severity of Illness Index , Tricuspid Valve Insufficiency/diagnostic imaging , Tricuspid Valve Insufficiency/surgery , Registries
11.
Catheter Cardiovasc Interv ; 103(1): 202-208, 2024 01.
Article in English | MEDLINE | ID: mdl-38009641

ABSTRACT

BACKGROUND: Conduction disturbances and the need for permanent pacemaker (PPM) implantation remains a common complication for transcatheter aortic valve replacement (TAVR), particularly when self-expanding (SE) valves are used. AIMS: We compared in-hospital and 30-day rates of new PPM implantation between patients undergoing TAVR with SE valves using the conventional three-cusp coplanar implantation technique and the cusp-overlap technique. METHODS: We retrospectively compared patients without a pre-existing PPM who underwent a TAVR procedure with SE Evolut R or PRO valves using the cusp-overlap technique from July 2018 to September 2020 (n = 519) to patients who underwent TAVR using standard three-cusp technique from April 2016 to March 2017 (n = 128) in two high volume Canadian centers. RESULTS: There was no significant difference in baseline RBBB between the groups (10.4% vs. 13.2; p = 0.35). The rate of in-hospital new complete heart block (9.4% vs. 23.4%; p ≤ 0.001) and PPM implantation (8% vs. 21%; p ≤ 0.001) were significantly reduced when using the cusp-overlap technique. The incidence of new LBBB (30.4% vs. 29%; p = 0.73) was similar. At 30 days, the rates of new complete heart block (11% vs. 23%; p ≤ 0.001) and PPM implantation (10% vs. 21%, p ≤ 0.001) remained significantly lower in the cusp-overlap group, while the rate of new LBBB (35% vs. 30%; p = 0.73) was similar. CONCLUSION: Cusp-overlap approach offers several potential technical advantages compared to standard three-cusp view, and may result in lower PPM rates in TAVR with SE Evolut valve.


Subject(s)
Aortic Valve Stenosis , Atrioventricular Block , Heart Valve Prosthesis , Pacemaker, Artificial , Transcatheter Aortic Valve Replacement , Humans , Transcatheter Aortic Valve Replacement/adverse effects , Aortic Valve Stenosis/diagnostic imaging , Aortic Valve Stenosis/surgery , Retrospective Studies , Risk Factors , Treatment Outcome , Prosthesis Design , Canada , Aortic Valve/diagnostic imaging , Aortic Valve/surgery
12.
Curr Opin Cardiol ; 39(2): 79-85, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38116841

ABSTRACT

PURPOSE OF REVIEW: Tricuspid transcatheter edge-to-edge repair (T-TEER) has emerged as a well tolerated and effective therapeutic option for many patients with symptomatic severe tricuspid regurgitation at prohibitive surgical risk. However, there remain several important limitations to clip-based technology in the context of other rapidly emerging percutaneous treatment options for tricuspid regurgitation. RECENT FINDINGS: Tricuspid lesions pose unique challenges to treatment with the current toolbox of transcatheter clip-based technologies. This review will explore key issues related to patient factors, anatomical factors, and imaging factors that may render lesions to be unsuitable for treatment with T-TEER. SUMMARY: Selection for T-TEER must include a detailed clinical evaluation in the context of a 'heart team' approach involving multiple subspecialists, with screening for patient/lesion characteristics that make T-TEER suboptimal with current clip-based technologies. Future directions for research include patient-specific 3D modeling techniques, leaflet grasping techniques, clip deployment strategies, and personalized device sizing to increase the spectrum of lesions that may be treated with T-TEER within the context of other emerging transcatheter treatment options.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/surgery , Heart Valve Prosthesis Implantation/adverse effects , Treatment Outcome , Cardiac Catheterization/methods , Forecasting
13.
Article in English | MEDLINE | ID: mdl-37962288

ABSTRACT

BACKGROUND: The CLASP IID (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical) trial is the first randomized controlled trial comparing the PASCAL system and the MitraClip system in prohibitive risk patients with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: The study sought to report primary and secondary endpoints and 1-year outcomes for the full cohort of the CLASP IID trial. METHODS: Prohibitive-risk patients with 3+/4+ DMR were randomized 2:1 (PASCAL:MitraClip). One-year assessments included secondary effectiveness endpoints (mitral regurgitation [MR] ≤2+ and MR ≤1+), and clinical, echocardiographic, functional, and quality-of-life outcomes. Primary safety (30-day composite major adverse events [MAE]) and effectiveness (6-month MR ≤2+) endpoints were assessed for the full cohort. RESULTS: Three hundred patients were randomized (PASCAL: n = 204; MitraClip: n = 96). At 1 year, differences in survival, freedom from heart failure hospitalization, and MAE were nonsignificant (P > 0.05 for all). Noninferiority of the PASCAL system compared with the MitraClip system persisted for the primary endpoints in the full cohort (For PASCAL vs MitraClip, the 30-day MAE rates were 4.6% vs 5.4% with a rate difference of -0.8% and 95% upper confidence bound of 4.6%. The 6-month MR≤2+ rates were 97.9% vs 95.7% with a rate difference of 2.2% and 95% lower confidence bound (LCB) of -2.5%, for, respectively). Noninferiority was met for the secondary effectiveness endpoints at 1 year (MR≤2+ rates for PASCAL vs MitraClip were 95.8% vs 93.8% with a rate difference of 2.1% and 95% LCB of -4.1%. The MR≤1+ rates were 77.1% vs 71.3% with a rate difference of 5.8% and 95% LCB of -5.3%, respectively). Significant improvements in functional classification and quality of life were sustained in both groups (P <0.05 for all vs baseline). CONCLUSIONS: The CLASP IID trial full cohort met primary and secondary noninferiority endpoints, and at 1 year, the PASCAL system demonstrated high survival, significant MR reduction, and sustained improvements in functional and quality-of-life outcomes. Results affirm the PASCAL system as a beneficial therapy for prohibitive-surgical-risk patients with significant symptomatic DMR.

15.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Article in English | MEDLINE | ID: mdl-37930776

ABSTRACT

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Subject(s)
Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Female , Aged , Male , Tricuspid Valve Insufficiency/epidemiology , Tricuspid Valve Insufficiency/surgery , Tricuspid Valve/surgery , Heart Valve Prosthesis Implantation/methods , Prospective Studies , Quality of Life , Treatment Outcome , Cardiac Catheterization/methods , Severity of Illness Index
16.
Eur J Heart Fail ; 25(12): 2243-2251, 2023 Dec.
Article in English | MEDLINE | ID: mdl-37905381

ABSTRACT

AIM: Functional or secondary tricuspid regurgitation (STR) is the most common phenotype of tricuspid regurgitation (TR) with atrial STR (ASTR) and ventricular STR (VSTR) being recently identified as two distinct entities. Data on tricuspid transcatheter edge-to-edge repair (T-TEER) in patients with STR according to phenotype (i.e. ASTR vs. VSTR) are lacking. The aim of this study was to assess characteristics and outcomes of patients with ASTR versus VSTR undergoing T-TEER. METHODS AND RESULTS: Patients with STR undergoing T-TEER were selected from the Transcatheter Tricuspid Valve Therapies (TriValve) registry. ASTR was defined by (i) left ventricular ejection fraction ≥50%, (ii) atrial fibrillation, and (iii) systolic pulmonary artery pressure <50 mmHg. Patients not matching these criteria were classified as VSTR. Patients with primary TR and cardiac implantable electronic device were excluded. Key endpoints included procedural success and survival at follow-up. A total of 298 patients were enrolled in the study: 65 (22%) with ASTR and 233 (78%) with VSTR. Procedural success was similar in the two groups (80% vs. 83% for ASTR vs. VSTR, p = 0.56) and TEER was effective in reducing TR in both groups (from 97% of patients with baseline TR ≥3+ to 23% in ASTR and to 15% in VSTR, all p = 0.001). At 12-month follow-up, survival was significantly higher in the ASTR versus VSTR cohort (91% vs. 72%, log-rank p = 0.02), with VSTR being an independent predictor of mortality at multivariable analysis (hazard ratio 4.75). CONCLUSIONS: In a real-world, multicentre registry, T-TEER was effective in reducing TR grade in both ASTR and VSTR. At 12-month follow-up, ASTR showed better survival than VSTR.


Subject(s)
Heart Failure , Heart Valve Prosthesis Implantation , Tricuspid Valve Insufficiency , Humans , Tricuspid Valve Insufficiency/complications , Tricuspid Valve Insufficiency/surgery , Heart Valve Prosthesis Implantation/methods , Stroke Volume , Treatment Outcome , Cardiac Catheterization/methods , Heart Failure/etiology , Ventricular Function, Left , Registries
17.
Ann Thorac Surg ; 2023 Sep 17.
Article in English | MEDLINE | ID: mdl-37717882

ABSTRACT

BACKGROUND: Whether transcatheter mitral valve replacement (TMVR) devices perform similarly with respect to the underlying mitral regurgitation (MR) etiology remains unknown. The aim of the present analysis was to assess outcomes of TMVR according to the MR underlying etiology among the CHoice of OptImal transCatheter trEatment for Mitral Insufficiency (CHOICE-MI) registry. METHODS: Of 746 patients, 229 patients (30.7%) underwent TMVR. The study population was subdivided according to primary, secondary, or mixed MR. Patients with mitral annular calcification were excluded. The primary study endpoint was a composite endpoint of all-cause mortality or hospitalization for heart failure at 1 year. Secondary study endpoints were all-cause and cardiovascular mortality at 1 year, New York Heart Association functional class, and residual MR, both at discharge and 1 year. RESULTS: The predominant MR etiology was secondary MR (58.4%), followed by primary MR (28.7%) and mixed MR (12.9%). Technical success and procedural mortality were similar according to MR etiology. Discharge echocardiography revealed residual MR 2+ in 11.3%, 3.7%, and 5.3% of patients with primary, secondary, and mixed MR, respectively (P = .1). MR elimination was similar in all groups up to the 1-year follow-up. There was no difference in terms of primary combined outcome occurrence according to MR etiology. One-year all-cause mortality was reported in 28.8%, 24.2%, and 32.1% of patients with primary, secondary, and mixed MR, respectively (P = .07). CONCLUSIONS: In our study we did not find differences in short-term and 1-year outcomes after TMVR according to MR etiology.

18.
Int J Cardiol ; 390: 131139, 2023 11 01.
Article in English | MEDLINE | ID: mdl-37355239

ABSTRACT

BACKGROUND: In the first report from the MitraBridge registry, MitraClip as a bridge to heart transplantation (HTx) proved to be at 1-year an effective treatment strategy for 119 patients with advanced heart failure (HF) who were potential candidates for HTx. We aimed to determine if benefits of MitraClip procedure as a bridge-to-transplant persist up to 2-years. METHODS: By the end of the enrollment period, a total of 153 advanced HF patients (median age 59 years, left ventricular ejection fraction 26.9 ± 7.7%) with significant secondary mitral regurgitation, who were potential candidates for HTx and were treated with MitraClip as a bridge-to-transplant strategy, were included in the MitraBridge registry. The primary endpoint was the 2-year composite adverse events rate of all-cause death, first hospitalization for HF, urgent HTx or LVAD implantation. RESULTS: Procedural success was achieved in 89.5% of cases. Thirty-day mortality was 0%. At 2-year, Kaplan-Meier estimates of freedom from primary endpoint was 47%. Through 24 months, the annualized rate of HF rehospitalization per patient-year was 44%. After an overall median follow-up time of 26 (9-52) months, elective HTx was successfully performed in 30 cases (21%), 19 patients (13.5%) maintained or obtained the eligibility for transplant, and 32 patients (22.5%) no longer had an indication for HTx because of significant clinical improvement. CONCLUSIONS: After 2-years of follow-up, the use of MitraClip as a bridge-to-transplant was confirmed as an effective strategy, allowing elective HTx or eligibility for transplant in one third of patients, and no more need for transplantation in 22.5% of cases.


Subject(s)
Heart Failure , Heart Transplantation , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Middle Aged , Stroke Volume , Ventricular Function, Left , Time Factors , Heart Transplantation/adverse effects , Treatment Outcome , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Heart Failure/diagnosis , Heart Failure/surgery , Registries , Heart Valve Prosthesis Implantation/methods
19.
J Am Heart Assoc ; 12(13): e029735, 2023 07 04.
Article in English | MEDLINE | ID: mdl-37345813

ABSTRACT

Background Little is known about the impact of transcatheter mitral valve edge-to-edge repair on changes in left ventricular ejection fraction (LVEF) and the effect of an acute reduction in LVEF on prognosis. We aimed to assess changes in LVEF after transcatheter mitral valve edge-to-edge repair for both primary and secondary mitral regurgitation (PMR and SMR, respectively), identify rates and predictors of LVEF reduction, and estimate its impact on prognosis. Methods and Results In this international multicenter registry, patients with both PMR and SMR undergoing transcatheter mitral valve edge-to-edge repair were included. We assessed rates of acute LVEF reduction (LVEFR), defined as an acute relative decrease of >15% in LVEF, its impact on all-cause mortality, major adverse cardiac event (composite end point of all-cause death, mitral valve surgery, and residual mitral regurgitation grade ≥2), and LVEF at 12 months, as well as predictors for LVEFR. Of 2534 patients included (727 with PMR, and 1807 with SMR), 469 (18.5%) developed LVEFR. Patients with PMR were older (79.0±9.2 versus 71.8±8.9 years; P<0.001) and had higher mean LVEF (54.8±14.0% versus 32.7±10.4%; P<0.001) at baseline. After 6 to 12 months (median, 9.9 months; interquartile range, 7.8-11.9 months), LVEF was significantly lower in patients with PMR (53.0% versus 56.0%; P<0.001) but not in patients with SMR. The 1-year mortality was higher in patients with PMR with LVEFR (16.9% versus 9.7%; P<0.001) but not in those with SMR (P=0.236). LVEF at baseline (odds ratio, 1.03 [95% CI, 1.01-1.05]; P=0.002) was predictive of LVEFR for patients with PMR, but not those with SMR (P=0.092). Conclusions Reduction in LVEF is not uncommon after transcatheter mitral valve edge-to-edge repair and is correlated with worsened prognosis in patients with PMR but not patients with SMR. Registration URL: https://www.clinicaltrials.gov; Unique identifier: NCT05311163.


Subject(s)
Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Ventricular Function, Left , Stroke Volume , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Treatment Outcome , Heart Valve Prosthesis Implantation/methods
20.
Catheter Cardiovasc Interv ; 102(1): 145-154, 2023 07.
Article in English | MEDLINE | ID: mdl-37178388

ABSTRACT

BACKGROUND: Mitral valve transcatheter edge-to-edge repair (M-TEER) is an effective option for treatment of mitral regurgitation (MR). We previously reported favorable 2-year outcomes for the PASCAL transcatheter valve repair system. OBJECTIVES: We report 3-year outcomes from the multinational, prospective, single-arm CLASP study with analysis by functional MR (FMR) and degenerative MR (DMR). METHODS: Patients with core-lab determined MR ≥ 3+ were deemed candidates for M-TEER by the local heart team. Major adverse events were assessed by an independent clinical events committee to 1 year and by sites thereafter. Echocardiographic outcomes were evaluated by the core laboratory to 3 years. RESULTS: The study enrolled 124 patients, 69% FMR; 31% DMR (60% NYHA class III-IVa, 100% MR ≥ 3+). The 3-year Kaplan-Meier estimate for survival was 75% (66% FMR; 92% DMR) and freedom from heart failure hospitalization (HFH) was 73% (64% FMR; 91% DMR), with 85% reduction in annualized HFH rate (81% FMR; 96% DMR) (p < 0.001). MR ≤ 2+ was achieved and maintained in 93% of patients (93% FMR; 94% DMR) and MR ≤ 1+ in 70% of patients (71% FMR; 67% DMR) (p < 0.001). The mean left ventricular end-diastolic volume (181 mL at baseline) decreased progressively by 28 mL [p < 0.001]. NYHA class I/II was achieved in 89% of patients (p < 0.001). CONCLUSIONS: The 3-year results from the CLASP study demonstrated favorable and durable outcomes with the PASCAL transcatheter valve repair system in patients with clinically significant MR. These results add to the growing body of evidence establishing the PASCAL system as a valuable therapy for patients with significant symptomatic MR.


Subject(s)
Cardiac Surgical Procedures , Heart Valve Prosthesis Implantation , Mitral Valve Insufficiency , Humans , Mitral Valve Insufficiency/diagnostic imaging , Mitral Valve Insufficiency/surgery , Mitral Valve/diagnostic imaging , Mitral Valve/surgery , Prospective Studies , Treatment Outcome
SELECTION OF CITATIONS
SEARCH DETAIL
...