Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 804
Filter
1.
Front Bioeng Biotechnol ; 12: 1363780, 2024.
Article in English | MEDLINE | ID: mdl-38756412

ABSTRACT

Articular cartilage injuries present a significant global challenge, particularly in the aging population. These injuries not only restrict movement due to primary damage but also exacerbate elderly degenerative lesions, leading to secondary cartilage injury and osteoarthritis. Addressing osteoarthritis and cartilage damage involves overcoming several technical challenges in biological treatment. The use of induced mesenchymal stem cells (iMSCs) with functional gene modifications emerges as a solution, providing a more stable and controllable source of Mesenchymal Stem Cells (MSCs) with reduced heterogeneity. Furthermore, In addition, this review encompasses strategies aimed at enhancing exosome efficacy, comprising the cultivation of MSCs in three-dimensional matrices, augmentation of functional constituents within MSC-derived exosomes, and modification of their surface characteristics. Finally, we delve into the mechanisms through which MSC-exosomes, sourced from diverse tissues, thwart osteoarthritis (OA) progression and facilitate cartilage repair. This review lays a foundational framework for engineering iMSC-exosomes treatment of patients suffering from osteoarthritis and articular cartilage injuries, highlighting cutting-edge research and potential therapeutic pathways.

2.
Genes Genomics ; 2024 May 28.
Article in English | MEDLINE | ID: mdl-38807022

ABSTRACT

BACKGROUND: Liver cancer is one of the most malignant liver diseases in the world, and the 5-year survival rate of such patients is low. Analgesics are often used to cure pain prevalent in liver cancer. The expression changes and clinical significance of the analgesic targets (ATs) in liver cancer have not been deeply understood. OBJECTIVE: The purpose of this study is to clarify the expression pattern of ATs gene in liver cancer and its clinical significance. Through the comprehensive analysis of transcriptome data and clinical parameters, the prognosis model related to ATs gene is established, and the drug information sensitive to ATs is mined. METHODS: The study primarily utilized transcriptomic data and clinical information from liver cancer patients sourced from The Cancer Genome Atlas (TCGA) database. These data were employed to analyze the expression of ATs, conduct survival analysis, gene set variation analysis (GSVA), immune cell infiltration analysis, establish a prognostic model, and perform other bioinformatic analyses. Additionally, data from liver cancer patients in the International Cancer Genome Consortium (ICGC) were utilized to validate the accuracy of the model. Furthermore, the impact of analgesics on key genes in the prognostic model was assessed using data from the Comparative Toxicogenomics Database (CTD). RESULTS: The study investigated the differential expression of 58 ATs genes in liver cancer compared to normal tissues. Patients were stratified based on ATs expression, revealing varied survival outcomes. Functional enrichment analysis highlighted distinctions in spindle organization, centrosome, and spindle microtubule functions. Prognostic modeling identified low TP53 expression as protective, while elevated CCNA2, NEU1, and HTR2C levels posed risks. Commonly used analgesics, including acetaminophen and others, were found to influence the expression of these genes. These findings provide insights into potential therapeutic strategies for liver cancer and shed light on the molecular mechanisms underlying its progression. CONCLUSIONS: The collective analysis of gene signatures associated with ATs suggests their potential as prognostic predictors in hepatocellular carcinoma patients. These findings not only offer insights into cancer therapy but also provide novel avenues for the development of indications for analgesics.

4.
Int Immunopharmacol ; 134: 112212, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38728882

ABSTRACT

Chronic myeloid leukemia (CML) is a type of hematologic malignancies caused by BCR-ABL chimeric oncogene. Resistance to tyrosine kinase inhibitors (TKIs) leads to the progression of CML into advanced stages. Selinexor is a small molecule inhibitor that targets a nuclear transporter called Exportin 1. Combined with imatinib, selinexor has been shown to disrupt nuclear-cytoplasmic transport signal of leukemia stem cells, resulting in cell death. The objective of this study was to investigate the mechanism of drug resistance to selinexor in CML. We established K562 cell line resistant to selinexor and conducted single cell dynamic transcriptome sequencing to analyze the heterogeneity within the parental and selinexor resistant cell populations. We identified specific gene expression changes associated with resistance to selinexor. Our results revealed differential expression patterns in genes such as MT2A, TFPI, MTND3, and HMGCS1 in the total RNA, as well as MT-TW, DNAJB1, and HSPB1 in the newly synthesized RNA, between the parental and drug-resistant groups. By applying pseudo-time analysis, we discovered that a specific cluster of cells exhibited characteristics of tumor stem cells. Furthermore, we observed a gradual decrease in the expression of ferroptosis-related molecules as drug resistance developed. In vitro experiments confirmed that the combination of a ferroptosis inducer called RSL3 effectively overcame drug resistance. In conclusion, this study revealed the resistance mechanism of selinexor in CML. In conclusion, we identified a subgroup of CML cells with tumor stem cell properties and demonstrated that ferroptosis inducer improved the efficacy of selinexor in overcoming drug resistance.


Subject(s)
Drug Resistance, Neoplasm , Hydrazines , Leukemia, Myelogenous, Chronic, BCR-ABL Positive , Triazoles , Humans , Hydrazines/pharmacology , Hydrazines/therapeutic use , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/drug therapy , Leukemia, Myelogenous, Chronic, BCR-ABL Positive/genetics , Drug Resistance, Neoplasm/genetics , Triazoles/pharmacology , K562 Cells , Single-Cell Analysis , Antineoplastic Agents/pharmacology , Antineoplastic Agents/therapeutic use , RNA-Seq , Single-Cell Gene Expression Analysis
5.
Aging (Albany NY) ; 16(9): 8171-8197, 2024 May 10.
Article in English | MEDLINE | ID: mdl-38738999

ABSTRACT

BACKGROUND: LRRC59 is a leucine-rich repeats-containing protein located in the endoplasmic reticulum (ER), it serves as a prognostic marker in several cancers. However, there has been no systematic analysis of its role in the tumor immune microenvironment, nor its predictive value of prognosis and immunotherapy response in different cancers. METHODS: A comprehensive pan-cancer analysis of LRRC59 was conducted from various databases to elucidate the associations between its expression and the prognosis of cancer, genetic alterations, tumor metabolism, and tumor immunity. Additionally, further functional assays were performed in hepatocellular carcinoma (HCC) to study its biological role in regulating cell proliferation, migration, apoptosis, cell cycle arrest, and sensitivity to immunotherapy. RESULTS: The pan-cancer analysis reveals a significant upregulation of LRRC59 in pan-cancer, and its overexpression is correlated with unfavorable prognosis in cancer patients. LRRC59 is negatively correlated with immune cell infiltration, tumor purity estimation, and immune checkpoint genes. Finally, the validation in HCC demonstrates LRRC59 is significantly overexpressed in cancer tissue and cell lines, and its knockdown inhibits cell proliferation and migration, promotes cell apoptosis, induces cell cycle arrest, and enhances the sensitivity to immunotherapy in HCC cells. CONCLUSIONS: LRRC59 emerges as a novel potential prognostic biomarker across malignancies, offering promise for anti-cancer drugs and immunotherapy.


Subject(s)
Carcinoma, Hepatocellular , Liver Neoplasms , Humans , Carcinoma, Hepatocellular/immunology , Carcinoma, Hepatocellular/genetics , Carcinoma, Hepatocellular/pathology , Liver Neoplasms/immunology , Liver Neoplasms/genetics , Liver Neoplasms/pathology , Prognosis , Cell Line, Tumor , Cell Proliferation/genetics , Biomarkers, Tumor/genetics , Biomarkers, Tumor/metabolism , Gene Expression Regulation, Neoplastic , Tumor Microenvironment/immunology , Tumor Microenvironment/genetics , Apoptosis/genetics , Membrane Proteins/genetics , Membrane Proteins/metabolism , Cell Movement/genetics , Immunotherapy
6.
Cancer Cell ; 42(4): 701-719.e12, 2024 Apr 08.
Article in English | MEDLINE | ID: mdl-38593782

ABSTRACT

Co-occurrence and mutual exclusivity of genomic alterations may reflect the existence of genetic interactions, potentially shaping distinct biological phenotypes and impacting therapeutic response in breast cancer. However, our understanding of them remains limited. Herein, we investigate a large-scale multi-omics cohort (n = 873) and a real-world clinical sequencing cohort (n = 4,405) including several clinical trials with detailed treatment outcomes and perform functional validation in patient-derived organoids, tumor fragments, and in vivo models. Through this comprehensive approach, we construct a network comprising co-alterations and mutually exclusive events and characterize their therapeutic potential and underlying biological basis. Notably, we identify associations between TP53mut-AURKAamp and endocrine therapy resistance, germline BRCA1mut-MYCamp and improved sensitivity to PARP inhibitors, and TP53mut-MYBamp and immunotherapy resistance. Furthermore, we reveal that precision treatment strategies informed by co-alterations hold promise to improve patient outcomes. Our study highlights the significance of genetic interactions in guiding genome-informed treatment decisions beyond single driver alterations.


Subject(s)
Breast Neoplasms , Humans , Female , Breast Neoplasms/drug therapy , Breast Neoplasms/genetics , Breast Neoplasms/pathology , Genomics , Treatment Outcome , Phenotype , Mutation
7.
Opt Express ; 32(7): 12200-12212, 2024 Mar 25.
Article in English | MEDLINE | ID: mdl-38571050

ABSTRACT

As an integral component of the laser interferometry measurement system, the tilt-to-length (TTL) coupling noise inside the telescope stands out as a critical noise factor that requires meticulous consideration. In the TianQin project, the non-geometric TTL-coupled noise inside the telescope should be less than 0.22 pm/Hz1/2. Additionally, the wavefront aberration RMS at the small pupil of the telescope needs to be better than 0.0065 λ. These requirements set for the telescope are exceptionally stringent. To address this challenge, this study aims to relax the wavefront aberration requirements by mitigating non-geometric TTL coupling noise, while ensuring the non-geometric TTL coupling noise remains below 0.22 pm/Hz1/2. By controlling the coupling aberration proportion, the wavefront aberration RMS at the small pupil of the telescope can be relaxed to 0.014 λ. Alternatively, optimizing the Gaussian beam waist radius can relax the wavefront aberration RMS to 0.016 λ. By simultaneously utilizing two optimization methods, the wavefront aberration at the small pupil of the telescope can be reduced to 0.033 λ, resulting in an impressive success rate of 91.15% in meeting the noise requirements.

8.
Nanoscale ; 16(22): 10682-10689, 2024 Jun 06.
Article in English | MEDLINE | ID: mdl-38687297

ABSTRACT

A one-step solvent-mediated transfer printing technology (sTPT) is proposed to fabricate printable silver (Ag) electrodes. This simple approach can realize the residuals in the active layer serving as the mediator due to the capillary action without the use of any additional solvent. The as-cast polydimethylsiloxane (PDMS) was used as the stamp in the fabrication process. The residual solvent and the as-cast PDMS stamps simplified the fabrication process, while the transfer-printed Ag electrodes presented favorable conductivity and improved hydrophobicity due to the presence of residual PDMS on the surface of Ag, indicating the superiority as the top electrode for organic photodetectors (OPDs). Compared to the devices with the top Ag electrodes fabricated by the conventional evaporation method, we demonstrated that the OPDs with transfer-printed Ag electrodes presented better performance than that of the reference devices, including suppressed dark current, enlarged linear dynamic range, shortened response time, and optimized durability. These improved performances can be attributed to the fewer traps at the interface between the active layer and Ag electrodes. The sTPT may be a promising method for the fabrication of OPDs owing to the simplified fabrication process and enhanced device performance.

9.
Asian J Surg ; 47(6): 2613-2622, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38565445

ABSTRACT

BACKGROUND: The optimal proximal margin (PM) length for Siewert II/III adenocarcinoma of the esophagogastric junction (AEJ) remains unclear. This study aimed to determine the optimal PM length using an abdominal approach to guide surgical decision-making. METHODS: A prospective study analyzed 304 consecutive patients diagnosed with Siewert II/III AEJ between January 2019 and December 2021. Total gastrectomy was performed via the abdominal approach, and PM length was measured on fixed gross specimens. X-Tile software determined the optimal PM cut-point based on progression-free survival (PFS). Univariate analyses compared baseline characteristics across PM groups, while survival analyses utilized Kaplan-Meier estimation and Cox proportional hazards regression for assessing the impact of margin length on survival. Multivariable analyses were conducted to adjust for confounding variables. RESULTS: The study included 264 AEJ cases classified as Siewert II (71.97%) or III (28.03%). The median gross PM length was 1.0 cm (IQR: 0.5 cm-1.5 cm, range: 0 cm-6 cm). PM length ≥1.2 cm was associated with a lower risk of disease progression compared to PM length 0.4 cm on PFS (HR = 0.41, 95% CI 0.20-0.84, P = 0.015). Moreover, PM ≥ 1.2 cm improved prognosis in subgroups of T4 or N3, tumor size <4 cm, Siewert II, and Lauren classification. CONCLUSIONS: For Siewert type II/III AEJ, a proximal margin length ≥1.2 cm (1.65 cm in situ) is associated with improved outcomes. These findings offer valuable insights into the association between PM length and outcomes in Siewert II/III AEJ, providing guidance for surgical approaches and aiding clinical decision-making to enhance patient outcomes.


Subject(s)
Adenocarcinoma , Esophageal Neoplasms , Esophagogastric Junction , Gastrectomy , Margins of Excision , Stomach Neoplasms , Humans , Esophagogastric Junction/pathology , Esophagogastric Junction/surgery , Adenocarcinoma/surgery , Adenocarcinoma/pathology , Adenocarcinoma/mortality , Male , Female , Middle Aged , Gastrectomy/methods , Aged , Prognosis , Stomach Neoplasms/surgery , Stomach Neoplasms/pathology , Stomach Neoplasms/mortality , Prospective Studies , Esophageal Neoplasms/pathology , Esophageal Neoplasms/surgery , Esophageal Neoplasms/mortality
10.
Cell Biol Toxicol ; 40(1): 24, 2024 Apr 23.
Article in English | MEDLINE | ID: mdl-38653919

ABSTRACT

Elongin B (ELOB), a pivotal element in the ELOB/c-Cullin2/5-SOCS-box E3 ubiquitin-protein ligase complex, plays a significant role in catalyzing the ubiquitination and subsequent degradation of a broad spectrum of target proteins. Notably, it is documented to facilitate these processes. However, the regulatory role of ELOB in breast cancer remains ambiguous. In this study, through bio-informatic analysis of The Cancer Genome Atlas and Fudan University Shanghai Cancer Center database, we demonstrated that ELOB was over-expressed in breast cancer tissues and was related to unfavorable prognosis. Additionally, pathway enrichment analysis illustrated that high expression of ELOB was associated with multiple cancer promoting pathways, like cell cycle, DNA replication, proteasome and PI3K - Akt signaling pathway, indicating ELOB as a potential anticancer target. Then, we confirmed that both in vivo and in vitro, the proliferation of breast cancer cells could be significantly suppressed by the down-regulation of ELOB. Mechanically, immunoprecipitation and in vivo ubiquitination assays prompted that, as the core element of Cullin2-RBX1-ELOB E3 ligase (CRL2) complex, ELOB regulated the ubiquitination and the subsequent degradation of oncoprotein p14/ARF. Moreover, the anticancer efficacy of erasing ELOB could be rescued by simultaneous knockdown of p14/ARF. Finally, through analyzing breast cancer tissue microarrays and western blot of patient samples, we demonstrated that the expression of ELOB in tumor tissues was elevated in compared to adjacent normal tissues. In conclusion, ELOB is identified to be a promising innovative target for the drug development of breast cancer by promoting the ubiquitination and degradation of oncoprotein p14/ARF.


Subject(s)
Breast Neoplasms , Cell Proliferation , Elongin , Ubiquitination , Humans , Breast Neoplasms/metabolism , Breast Neoplasms/pathology , Breast Neoplasms/genetics , Female , Elongin/metabolism , Elongin/genetics , Animals , Cell Line, Tumor , Cell Proliferation/genetics , Disease Progression , Mice, Nude , Mice , Gene Expression Regulation, Neoplastic , Signal Transduction , Mice, Inbred BALB C , MCF-7 Cells , Transcription Factors/metabolism , Transcription Factors/genetics
11.
Adv Healthc Mater ; : e2304532, 2024 Mar 27.
Article in English | MEDLINE | ID: mdl-38533604

ABSTRACT

In vitro blood vessel models are significant for disease modeling, drug assays, and therapeutic development. Microfluidic technologies allow to create physiologically relevant culture models reproducing the features of the in vivo vascular microenvironment. However, current microfluidic technologies are limited by impractical rectangular cross-sections and single or nonsynchronous compound mechanical stimuli. This study proposes a new strategy for creating round-shaped deformable soft microfluidic channels to serve as artificial in vitro vasculature for developing in vitro models with vascular physio-mechanical microenvironments. Endothelial cells seeded into vascular models are used to assess the effects of a remodeled in vivo mechanical environment. Furthermore, a 3D stenosis model is constructed to recapitulate the flow disturbances in atherosclerosis. Soft microchannels can also be integrated into traditional microfluidics to realize multifunctional composite systems. This technology provides new insights into applying microfluidic chips and a prospective approach for constructing in vitro blood vessel models.

12.
Immunology ; 172(2): 313-327, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38462236

ABSTRACT

This study longitudinally evaluated the immune response in individuals over a year after receiving three doses of an inactivated SARS-CoV-2 vaccine, focusing on reactions to Omicron breakthrough infections. From 63 blood samples of 37 subjects, results showed that the third booster enhanced the antibody response against Alpha, Beta, and Delta VOCs but was less effective against Omicron. Although antibody titres decreased post-vaccination, SARS-CoV-2-specific T-cell responses, both CD4+ and CD8+, remained stable. Omicron breakthrough infections significantly improved neutralization against various VOCs, including Omicron. However, the boost in antibodies against WT, Alpha, Beta, and Delta variants was more pronounced. Regarding T cells, breakthrough infection predominantly boosted the CD8+ T-cell response, and the intensity of the spike protein-specific T-cell response was roughly comparable between WT and Omicron BA.5.


Subject(s)
Antibodies, Viral , COVID-19 Vaccines , COVID-19 , SARS-CoV-2 , Vaccines, Inactivated , Humans , COVID-19 Vaccines/immunology , COVID-19 Vaccines/administration & dosage , SARS-CoV-2/immunology , COVID-19/prevention & control , COVID-19/immunology , Antibodies, Viral/blood , Antibodies, Viral/immunology , Male , Female , Vaccines, Inactivated/immunology , Vaccines, Inactivated/administration & dosage , Adult , Middle Aged , Antibodies, Neutralizing/immunology , Antibodies, Neutralizing/blood , CD8-Positive T-Lymphocytes/immunology , Vaccination/methods , Immunization, Secondary , Spike Glycoprotein, Coronavirus/immunology , CD4-Positive T-Lymphocytes/immunology , Aged , T-Lymphocytes/immunology , Breakthrough Infections
13.
Appl Opt ; 63(7): 1815-1821, 2024 Mar 01.
Article in English | MEDLINE | ID: mdl-38437285

ABSTRACT

The telescope is vital for accurate gravitational wave detection in the TianQin project. It must meet criteria like a geometric tilt-to-length (TTL) coupling noise c o e f f i c i e n t≤0.02√2n m/µr a d and wavefront R M S≤λ/30. Analyzing the pupil aberration's impact on geometric TTL noise, we devised an optimization method using the chief ray spot diagram's standard deviation. Implementing this in Zemax with a ZPL macro, we designed an optical system meeting TianQin's requirements. The system has a maximum geometric TTL noise coefficient of 0.0250 nm/µrad over the science FOV and a wavefront RMS of 0.0111λ, confirming the method's feasibility.

14.
Appl Opt ; 63(6): 1488-1494, 2024 Feb 20.
Article in English | MEDLINE | ID: mdl-38437360

ABSTRACT

The optical path length stability of the off-axis four-reflection telescope is one of the key technical indicators for the TianQin gravitational wave detection system. In the MHz observation band, the telescope must exhibit an optical path length stability of 0.4p m/H z 1/2. As a feasible solution, the optical path length stability measurement of the off-axis four-reflection telescope based on the Pound-Drever-Hall (PDH) technique imposes stringent requirements on the alignment of the off-axis resonant cavity (ORC). Taking the off-axis two-reflection prototype as the research object, we propose a Monte Carlo analysis-based method for ORC alignment precision analysis. By considering misalignment as an intermediate function, we establish a relationship between the coupling efficiency of the ORC and the wavefront aberration of the telescope. The research results show that by considering the combined effects of multiple misalignment couplings of the primary and secondary mirrors, when the detected telescope wavefront aberration is better than 0.068λ (λ=1064n m) with a probability of 98%, the ORC coupling efficiency can achieve greater than 40% with a probability of 97.13%, which can be used as the main reference indicator for system misalignment analysis. This method simplifies the alignment difficulty of the target under test and can provide alignment reference for subsequent resonant cavities with internal off-axis telescopes.

15.
J Appl Physiol (1985) ; 136(5): 1157-1169, 2024 May 01.
Article in English | MEDLINE | ID: mdl-38511210

ABSTRACT

The coronary sinus reducer (CSR) is an emerging medical device for treating patients with refractory angina, often associated with myocardial ischemia. Patients implanted with CSR have shown positive outcomes, but the underlying mechanisms are unclear. This study sought to understand the mechanisms of CSR by investigating its effects on coronary microcirculation hemodynamics that may help explain the therapy's efficacy. We applied a validated computer model of the coronary microcirculation to investigate how CSR affects hemodynamics under different degrees of coronary artery stenosis. With moderate coronary stenosis, an increase in capillary transit time (CTT) [up to 69% with near-complete coronary sinus (CS) occlusion] is the key change associated with CSR. Because capillaries in the microcirculation can still receive oxygenated blood from the upstream artery with moderate stenosis, the increase in CTT allows more time for the exchange of gases and nutrients, aiding tissue oxygenation. With severe coronary stenosis; however, the redistribution of blood draining from the nonischemic region to the ischemic region (up to 96% with near-complete CS occlusion) and the reduction in capillary flow heterogeneity are the key changes associated with CSR. Because blood draining from the nonischemic region is not completely devoid of O2, the redistribution of blood to the capillaries in the ischemic region by CSR is beneficial especially when little or no oxygenated blood reaches these capillaries. This simulation study provides insights into the mechanisms of CSR in improving clinical symptoms. The mechanisms differ with the severity of the upstream stenosis.NEW & NOTEWORTHY Emerging coronary venous retroperfusion treatments, particularly coronary sinus reducer (CSR) for refractory angina linked to myocardial ischemia, show promise; however, their mechanisms of action are not well understood. We find that CSR's effectiveness varies with the severity of coronary stenosis. In moderate stenosis, CSR improves tissue oxygenation by increasing capillary transit time, whereas in severe stenosis, it redistributes blood from nonischemic to ischemic regions and reduces capillary flow heterogeneity.


Subject(s)
Computer Simulation , Coronary Circulation , Coronary Sinus , Hemodynamics , Microcirculation , Myocardial Ischemia , Humans , Coronary Sinus/physiopathology , Myocardial Ischemia/physiopathology , Myocardial Ischemia/metabolism , Coronary Circulation/physiology , Hemodynamics/physiology , Microcirculation/physiology , Coronary Stenosis/physiopathology , Models, Cardiovascular
16.
ACS Omega ; 9(9): 10343-10352, 2024 Mar 05.
Article in English | MEDLINE | ID: mdl-38463336

ABSTRACT

Graphene oxide (GO) is an ideal reinforcing material with super design capability, which can achieve the combination of strength and toughness. However, the actual effect of GO is far below the theoretical prediction. This is mainly due to the weak interface between the nanofiller and the matrix. In this paper, a controllable method for improving interlayer stress transfer of double-layer graphene oxide/C-S-H (D-GO-CSH)-layered nanostructures is proposed by using interlayer sp3 bond and chirality. The results show that, compared with the control group, the normalized shear stress and normalized pull-out energy of the OH-sp3 model are increased by 44.93 and 49.25%, respectively, while those of the OO-sp3 model are increased by 32.26 and 31.03%, respectively. The interlayer sp3 bonds lead to a great enhancement (more than 3 times) in normalized interlayer stress transfer of D-GO-CSH-layered nanostructures while exerting a little opposite effect (about 5%). The improvement effects induced by the interlayer sp3 bonds are also strongly dependent on their distributions and the chirality of GO. According to the fracture mechanic theory and molecular dynamics results, the strain energy percentage difference (bond length and bond angle) of the zigzag-cen model is 34.8% lower than that of the control group model, which proves that the interlayer sp3 bonds have a remarkably positive effect on the interlayer stress transfer of D-GO-CSH-layered nanostructures. This provides a new way to further improve the interlayer stress transfer, pull-out energy, and interlayer shear stress of D-GO-CSH-layered nanostructures.

17.
Nanoscale ; 16(13): 6464-6476, 2024 Mar 28.
Article in English | MEDLINE | ID: mdl-38415750

ABSTRACT

The development of flexible pressure sensors for monitoring human motion and physiological signals has attracted extensive scientific research. However, achieving low monitoring limits, a wide detection range, large bending stresses, and excellent mechanical stability simultaneously remains a serious challenge. With the aim of developing a high-performance capacitive pressure sensor (CPS), this paper introduces the successful preparation of a single-walled carbon nanotube (SWNT)/polydimethylsiloxane (S-PDMS) composite dielectric with a foam-like structure (high permittivity and low elasticity modulus) and MXene/SWNT (S-MXene) composite film electrodes with a micro-crumpled structure. The above structurally modified CPS (SMCPS) demonstrated an excellent response output during pressure loading, achieving a wide pressure detection range (up to 700 kPa), a low detection limit (16.55 Pa), fast response/recovery characteristics (48/60 ms), enhanced sensitivity across a wide pressure range, long-term stability under repeated heavy loading and unloading (40 kPa, >2000 cycles), and reliable performance under various temperature and humidity conditions. The SMCPS demonstrated a precise and stable capacitive response in monitoring subtle physiological signals and detecting motion, owing to its unique electrode structure. The flexible device was integrated with an Internet of Things module to create a smart glove system that enables real-time tracking of dynamic gestures. This system demonstrates exceptional performance in gesture recognition and prediction with artificial intelligence analysis, highlighting the potential of the SMCPS in human-machine interface applications.

18.
Sci Rep ; 14(1): 3577, 2024 02 13.
Article in English | MEDLINE | ID: mdl-38347067

ABSTRACT

Osteosarcoma (OS) is the most common primary malignant tumor of bone. Remodelin, an inhibitor of the N (4)-Acetylcytidine (ac4C) acetylation modifying enzyme N-acetyltransferase 10 (NAT10), has been shown to have therapeutic effects on cancer in several studies, and our previous studies have confirmed the inhibitory effect of Remodelin on OS cells, however, the mechanism of action has not yet been elucidated. We used network pharmacological analysis to quantify the therapeutic targets of Remodelin against OS. acRIP-seq and RNA-seq were performed to investigate the inhibitory activity of Remodelin on acetylation and its effect on the transcriptome after intervening in OS cells U2OS with Remodelin in vitro. Key target genes were deduced based on their pharmacological properties, combined with network pharmacology results and sequencing results. Finally, the deduced target genes were validated with vitro experiments. Network pharmacological analysis showed that 2291 OS-related target genes and 369 Remodelin-related target genes were obtained, and 116 overlapping genes were identified as Remodelin targets for OS treatment. Sequencing results showed that a total of 13,736 statistically significant ac4C modification peaks were detected by acRIP-seq, including 6938 hypoacetylation modifications and 6798 hyperacetylation modifications. A total of 2350 statistically significant mRNAs were detected by RNA-seq, of which 830 were up-regulated and 1520 were down-regulated. Association analyses identified a total of 382 genes that were Hypoacetylated-down, consistent with inhibition of mRNA acetylation and expression by Remodelin. Five genes, CASP3, ESR2, FGFR2, IGF1 and MAPK1, were identified as key therapeutic targets of Remodelin against OS. Finally, in vitro experiments, CCK-8 and qRT-PCR demonstrated that Remodelin indeed inhibited the proliferation of OS cells and reduced the expression of three genes: ESR2, IGF1, and MAPK1. In conclusion, ESR2, IGF1 and MAPK1 were identified as key therapeutic targets of Remodelin against OS. This reveals the target of Remodelin's pharmacological action on OS and provides new ideas for the treatment of OS.


Subject(s)
Bone Neoplasms , Hydrazones , Osteosarcoma , Thiazoles , Humans , Network Pharmacology , Osteosarcoma/drug therapy , Osteosarcoma/genetics , Genes, Overlapping , Bone Neoplasms/drug therapy , Bone Neoplasms/genetics
19.
WIREs Mech Dis ; 16(3): e1642, 2024.
Article in English | MEDLINE | ID: mdl-38316634

ABSTRACT

Cardiac-coronary interaction is fundamental to the function of the heart. As one of the highest metabolic organs in the body, the cardiac oxygen demand is met by blood perfusion through the coronary vasculature. The coronary vasculature is largely embedded within the myocardial tissue which is continually contracting and hence squeezing the blood vessels. The myocardium-coronary vessel interaction is two-ways and complex. Here, we review the different types of cardiac-coronary interactions with a focus on insights gained from mathematical models. Specifically, we will consider the following: (1) myocardial-vessel mechanical interaction; (2) metabolic-flow interaction and regulation; (3) perfusion-contraction matching, and (4) chronic interactions between the myocardium and coronary vasculature. We also provide a discussion of the relevant experimental and clinical studies of different types of cardiac-coronary interactions. Finally, we highlight knowledge gaps, key challenges, and limitations of existing mathematical models along with future research directions to understand the unique myocardium-coronary coupling in the heart. This article is categorized under: Cardiovascular Diseases > Computational Models Cardiovascular Diseases > Biomedical Engineering Cardiovascular Diseases > Molecular and Cellular Physiology.


Subject(s)
Heart , Humans , Heart/physiology , Animals , Myocardium/metabolism , Models, Cardiovascular , Coronary Vessels/physiology , Coronary Circulation/physiology , Models, Theoretical
20.
Immun Inflamm Dis ; 12(2): e1202, 2024 Feb.
Article in English | MEDLINE | ID: mdl-38411294

ABSTRACT

BACKGROUND: Histiocytic necrotizing lymphadenitis (HNL) is a self-limited inflammatory disease of unknown pathogenesis. A very small fraction of patients with HNL could develop hemophagocytic lymphohistiocytosis (HLH), a hyperinflammatory disorder. These patients are diagnosed as HNL with HLH (HNL-HLH). HNL-HLH in the pediatric population has been systemically studied, however, the clinical, laboratory, and radiological features and outcomes of adult patients with HNL-HLH remain to be explored. We aimed to explore the clinical, laboratory, and radiological features and outcomes of adult patients with HNL-HLH. METHODS: We collected the clinical data of patients with HNL-HLH admitted to the First Affiliated Hospital of Nanjing Medical University from October 2010 to June 2015. All the patients underwent lymph node biopsy and have a pathological diagnosis of HNL. The age, gender, clinical presentation, lymph node signs, laboratory findings and imaging data, and pathological findings of the patients were collected. RESULTS: In this study, we reported five adult patients with HNL-HLH. All five patients showed enlarged lymph nodes and prolonged fever. Laboratory findings were consistent with the diagnosis of HLH. 18F-fluorodeoxyglucose positron emission tomography/computed tomography (18F-FDG PET/CT) showed enlarged lymph nodes with increased FDG uptake and splenic hypermetabolism could be present. All the patients responded well to corticosteroids and had a good prognosis. Two of the five patients were diagnosed with systemic lupus erythematosus during the follow-up. CONCLUSIONS: Our study demonstrated that adult patients with HNL-HLH showed distinct clinical, laboratory, and radiological features. And the prognosis is good and patients could be managed with steroids and supportive care.


Subject(s)
Histiocytic Necrotizing Lymphadenitis , Lymphohistiocytosis, Hemophagocytic , Adult , Humans , Child , Histiocytic Necrotizing Lymphadenitis/complications , Histiocytic Necrotizing Lymphadenitis/diagnosis , Histiocytic Necrotizing Lymphadenitis/drug therapy , Lymphohistiocytosis, Hemophagocytic/complications , Lymphohistiocytosis, Hemophagocytic/diagnosis , Lymphohistiocytosis, Hemophagocytic/drug therapy , Positron Emission Tomography Computed Tomography/adverse effects , Lymph Nodes , Biopsy/adverse effects
SELECTION OF CITATIONS
SEARCH DETAIL
...