Cardiol J ; 22(1): 57-67, 2015.
Article in English | MEDLINE | ID: mdl-24846515

ABSTRACT

BACKGROUND: Implantable cardioverter-defibrillator leads from Riata® family (St. Jude Medical Inc., Sylmar, CA, USA) have been recently recalled by Food and Drug Administration for concerns of a unique type of "inside-out" insulation failure leading to conductor externalization. The objective of this study was to evaluate the prevalence and predictors of conductor externalization in patients implanted with Riata 8 French (Fr) and 7 Fr leads. METHODS: Patients implanted with Riata® and Riata ST® who were actively followed up in our institution were scheduled for high resolution 3 view fluoroscopy and device interrogation including high voltage (HV) lead impedance testing. Fluoroscopic images were graded as presence of externalization or no externalization. RESULTS: Of the 90 patients who underwent screening fluoroscopy, majority had dual coil leads (62.5%) and median duration from the implant time to screening was 79.5 months. Twenty four (26.7%) patients exhibited evidence of lead externalization with 10 (41.6%) of these showing electrical abnormalities at the time of screening. No externalization was seen in the 7 Fr leads. Pacing thresholds were significantly elevated in the externalized cohort compared to non-externalized group (1.42 ± 1.23 vs. 0.93 ± 0.53; p = 0.01). Time since lead implant and lead diameter emerged as significant predictors of lead externalization on univariate analysis with only lead diameter being significant on multivariate analysis (odds ratio 30.68; 4.95-∞, p = 0.001). CONCLUSIONS: Prevalence of insulation failure exhibiting as conductor externalization is high (26.7%) among the large diameter 8 Fr Riata® leads with a significant proportion of patients manifesting electrical failure. High resolution 3 view fluoroscopy is a reasonable approach to screen for this unique type of insulation failure.


Subject(s)
Death, Sudden, Cardiac/prevention & control , Defibrillators, Implantable/adverse effects , Electric Countershock/adverse effects , Foreign-Body Migration/diagnostic imaging , Prosthesis Failure , Aged , Aged, 80 and over , Chi-Square Distribution , Databases, Factual , Death, Sudden, Cardiac/etiology , Electric Countershock/instrumentation , Electric Impedance , Female , Fluoroscopy , Foreign-Body Migration/epidemiology , Humans , Male , Medical Device Recalls , Middle Aged , Multivariate Analysis , Odds Ratio , Prevalence , Prosthesis Design , Retrospective Studies , Risk Factors , Time Factors , Treatment Outcome , United States , United States Food and Drug Administration
SELECTION OF CITATIONS
SEARCH DETAIL
...