Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters










Database
Language
Publication year range
1.
Opt Express ; 32(11): 19042-19056, 2024 May 20.
Article in English | MEDLINE | ID: mdl-38859048

ABSTRACT

Lidar using active light illumination is capable of capturing depth and reflectivity information of target scenes. Among various technologies, streak tube imaging lidar (STIL) has garnered significant attention due to its high resolution and excellent precision. The echo signals of a STIL system using single laser pulse are often overwhelmed by noise in complex environments, making it difficult to discern the range of the target. By combining high-frequency laser pulses with the repetitive sweep circuit, the STIL system enables efficient detection of few-photons signal in weak-light environments. Additionally, we have developed a robust algorithm for estimating the depth and reflectivity images of targets. The results demonstrate that this lidar system achieves a depth resolution better than 0.5 mm and a ranging accuracy of 95 um. Furthermore, the imaging of natural scenes also validates the exceptional 3D imaging capability of this system.

2.
Appl Opt ; 61(25): 7401-7408, 2022 Sep 01.
Article in English | MEDLINE | ID: mdl-36256041

ABSTRACT

Streak tube imaging lidar (STIL) can obtain 4-D images of a target, and its performance is mainly determined by the streak tube sensor. To obtain a large field of view, we developed a streak tube with a photocathode length as large as 35.3 mm, which is larger than the commonly used ST-HDR (30 mm). At the same time, the temporal resolution and dynamic spatial resolution are 60 ps and 12 lp/mm, which are very suitable to obtain accurate target coordinates for 4-D imaging. In addition, the streak tube has a high detection sensitivity of 46 mA/W at 500 nm and, hence, prospects in remote imaging. To test the performance of the streak tube, an underwater STIL experiment was conducted. Echo signal processing was performed by means of a bandpass filter and a matched filter, and then the peak detection algorithm was used to reconstruct the image. The results indicate that a spatial resolution better than 9 mm is achieved in the limpid water with a depth of 20 m, and a range accuracy of 1 cm is achieved in the turbid water with a depth of 10 m. Such a performance suggests that the large-field streak tube is of great potential for underwater target imaging and other remote imaging applications.


Subject(s)
Algorithms , Tomography, X-Ray Computed , Tomography, X-Ray Computed/methods , Signal Processing, Computer-Assisted , Water
SELECTION OF CITATIONS
SEARCH DETAIL
...