Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 12 de 12
Filter
1.
Int J Environ Health Res ; : 1-11, 2024 May 13.
Article in English | MEDLINE | ID: mdl-38741242

ABSTRACT

The main aim of this study is to quantitatively evaluate the differences, in terms of exposure to PM (particulate matter), between WFO (working-from-office) and WFH (working-from-home) conditions. Two measurement surveys were performed: a long-term and a short-term campaign, focused on the monitoring of personal exposure to size-fractionated PM in these different working conditions. Results of the long-term campaign show that the WFH subject is exposed to higher (up to 4 times) PM concentration, compared to the WFO subject. Specific activities performed by the subjects impacted their exposure concentrations, even if the most relevant contribution to total exposure was made by desk work. Results of the short-term campaign indicate that the subjects can be divided into two groups: subjects most exposed during the WFH mode (HE_H - Higher_Exposure_Home) and subjects most exposed during the WFO mode (HE_O - Higher_Exposure_Office). HE_H group is exposed to levels of pollutants up to 4 times higher in the domestic than in the office environment, during the moment of desk work. The HE_O group is exposed to higher (double) concentration levels during desk work during the WFO day. Considering the possible growing trend towards remote work it is important to evaluate these "new domestic offices" comprehensively.

2.
Toxics ; 12(4)2024 Mar 22.
Article in English | MEDLINE | ID: mdl-38668456

ABSTRACT

This study aimed to assess the performance, in terms of precision and accuracy, of a prototype (called "P.ALP"-Ph.D. Air Quality Low-cost Project) developed for monitoring PM2.5 concentration levels. Four prototypes were co-located with reference instrumentation in four different microenvironments simulating real-world and working conditions, namely (i) office, (ii) home, (iii) outdoor, and (iv) occupational environments. The devices were evaluated for a total of 20 monitoring days (approximately 168 h) under a wide range of PM2.5 concentrations. The performances of the prototypes (based on the light-scattering working principle) were tested through different statistical methods. After the data acquisition and data cleaning processes, a linear regression analysis was performed to assess the precision (by comparing all possible pairs of devices) and the accuracy (by comparing the prototypes against the reference instrumentation) of the P.ALP. Moreover, the United States Environmental Protection Agency (US EPA) criteria were applied to assess the possible usage of this instrumentation, and to evaluate the eventual error trends of the P.ALP in the data storage process, Bland-Altman plots were also adopted. The outcomes of this study underlined that the P.ALP performed differently depending on the microenvironment in which it was tested and, consequently, on the PM2.5 concentrations. The device can monitor PM2.5 variations with acceptable results, but the performance cannot be considered satisfactory at extremely low and remarkably high PM2.5 concentrations. Thanks to modular components and open-source software, the tested device has the potential to be customized and adapted to better fit specific study design needs, but it must be implemented with ad hoc calibration factors depending on the application before being used in field.

3.
Article in English | MEDLINE | ID: mdl-36231411

ABSTRACT

The goals of this work are the evaluation of the performances of official methods in the challenging determination of Cr(VI) in Cr(III)-rich particulate matter, and the development of a novel and robust analytical protocol for this issue. A liquid chromatography inductively coupled plasma mass spectrometry apparatus (LC-ICP-MS), together with an isotope-enriched spike addition technique, was used to allow the study of Cr(III)/Cr(VI) interconversions during the extraction step. An original separation strategy based on Cr(OH)3 head-column stacking was developed to tolerate high concentrations of Cr(III) (up to 10 mg/kg, with a Cr(VI) limit of detection of 0.51 µg/kg) without the need of any sample pretreatment. After observing, the official extraction protocols always yield false positive values in the challenging situation of particulate matter of leather industries (where huge amounts of Cr(III) are present), a new extraction strategy was developed. The novel procedure involves a 48-h extraction at room temperature using a pH-8 phosphate buffer, which demonstrated that no Cr(III)/Cr(VI) interconversions occur during this phase. To get rid of any possible interference caused by co-extracted substances, the measurement of the redox potential, together with the addition of a Fe(II)/Fe(III) redox buffer was performed to fix chromium speciation during the overall analytical protocol.


Subject(s)
Chromium , Ferric Compounds , Chromium/analysis , Dust/analysis , Ferrous Compounds , Isotopes , Mass Spectrometry/methods , Particulate Matter/analysis , Phosphates
4.
Sensors (Basel) ; 22(13)2022 Jun 27.
Article in English | MEDLINE | ID: mdl-35808337

ABSTRACT

Over the last decade, technological advancements have been made available and applied in a wide range of applications in several work fields, ranging from personal to industrial enforcements. One of the emerging issues concerns occupational safety and health in the Fourth Industrial Revolution and, in more detail, it deals with how industrial hygienists could improve the risk-assessment process. A possible way to achieve these aims is the adoption of new exposure-monitoring tools. In this study, a systematic review of the up-to-date scientific literature has been performed to identify and discuss the most-used sensors that could be useful for occupational risk assessment, with the intent of highlighting their pros and cons. A total of 40 papers have been included in this manuscript. The results show that sensors able to investigate airborne pollutants (i.e., gaseous pollutants and particulate matter), environmental conditions, physical agents, and workers' postures could be usefully adopted in the risk-assessment process, since they could report significant data without significantly interfering with the job activities of the investigated subjects. To date, there are only few "next-generation" monitors and sensors (NGMSs) that could be effectively used on the workplace to preserve human health. Due to this fact, the development and the validation of new NGMSs will be crucial in the upcoming years, to adopt these technologies in occupational-risk assessment.


Subject(s)
Environmental Pollutants , Occupational Health , Humans , Particulate Matter/analysis , Risk Assessment , Technology , Workplace
5.
Article in English | MEDLINE | ID: mdl-36612837

ABSTRACT

Objective During the induction of gaseous anaesthesia, waste anaesthetic gases (WAGs) can be released into workplace air. Occupational exposure to high levels of halogenated WAGs may lead to adverse health effects; hence, it is important to measure WAGs concentration levels to perform risk assessment and for health protection purposes. Methods A systematic review of the scientific literature was conducted on two different scientific databases (Scopus and PubMed). A total of 101 studies, focused on sevoflurane, desflurane and isoflurane exposures in hospitals, were included in this review. Key information was extracted to provide (1) a description of the study designs (e.g., monitoring methods, investigated occupational settings, anaesthetic gases in use); (2) an evaluation of time trends in the measured concentrations of considered WAGs; (3) a critical evaluation of the sampling strategies, monitoring methods and instruments used. Results Environmental monitoring was prevalent (68%) and mainly used for occupational exposure assessment during adult anaesthesia (84% of cases). Real-time techniques such as photoacoustic spectroscopy and infrared spectrophotometry were used in 58% of the studies, while off-line approaches such as active or passive sampling followed by GC-MS analysis were used less frequently (39%). Conclusions The combination of different instrumental techniques allowing the collection of data with different time resolutions was quite scarce (3%) despite the fact that this would give the opportunity to obtain reliable data for testing the compliance with 8 h occupational exposure limit values and at the same time to evaluate short-term exposures.


Subject(s)
Air Pollutants, Occupational , Anesthetics, Inhalation , Occupational Exposure , Anesthetics, Inhalation/adverse effects , Anesthetics, Inhalation/analysis , Air Pollutants, Occupational/analysis , Operating Rooms , Occupational Exposure/adverse effects , Hospitals
6.
Sensors (Basel) ; 21(13)2021 Jun 30.
Article in English | MEDLINE | ID: mdl-34209443

ABSTRACT

In the last years, the issue of exposure assessment of airborne pollutants has been on the rise, both in the environmental and occupational fields. Increasingly severe national and international air quality standards, indoor air guidance values, and exposure limit values have been developed to protect the health of the general population and workers; this issue required a significant and continuous improvement in monitoring technologies to allow the execution of proper exposure assessment studies. One of the most interesting aspects in this field is the development of the "next-generation" of airborne pollutants monitors and sensors (NGMS). The principal aim of this review is to analyze and characterize the state of the art and of NGMS and their practical applications in exposure assessment studies. A systematic review of the literature was performed analyzing outcomes from three different databases (Scopus, PubMed, Isi Web of Knowledge); a total of 67 scientific papers were analyzed. The reviewing process was conducting systematically with the aim to extrapolate information about the specifications, technologies, and applicability of NGMSs in both environmental and occupational exposure assessment. The principal results of this review show that the use of NGMSs is becoming increasingly common in the scientific community for both environmental and occupational exposure assessment. The available studies outlined that NGMSs cannot be used as reference instrumentation in air monitoring for regulatory purposes, but at the same time, they can be easily adapted to more specific applications, improving exposure assessment studies in terms of spatiotemporal resolution, wearability, and adaptability to different types of projects and applications. Nevertheless, improvements needed to further enhance NGMSs performances and allow their wider use in the field of exposure assessment are also discussed.


Subject(s)
Air Pollutants , Air Pollution , Environmental Pollutants , Air Pollutants/analysis , Air Pollution/analysis , Environmental Monitoring , Humans
7.
Toxics ; 9(6)2021 Jun 12.
Article in English | MEDLINE | ID: mdl-34204794

ABSTRACT

Recently, the need to assess personal exposure in different micro-environments has been highlighted. Further, estimating the inhaled dose of pollutants is considerably one of the most interesting parameters to be explored to complete the fundamental information obtained through exposure assessment, especially if associated with a dose-response approach. To analyze the main results obtained from the studies related to the estimation of the inhaled dose of pollutants in different micro-environments (environments in which an individual spends a part of his day), and to identify the influence of different parameters on it, a systematic review of the literature was performed. The principal outcomes from the considered studies outlined that (i) exposure concentration and residence time are among the most important parameters to be evaluated in the estimation of the inhaled dose, especially in transport environments. Further, (ii) the pulmonary ventilation rate can be of particular interest during active commuting because of its increase, which increases the inhalation of pollutants. From a methodological point of view, the advent of increasingly miniaturized, portable and low-cost technologies could favor these kinds of studies, both for the measurement of atmospheric pollutants and the real-time evaluation of physiological parameters used for estimation of the inhaled dose. The main results of this review also show some knowledge gaps. In particular, numerous studies have been conducted for the evaluation (in terms of personal exposure and estimation of the inhaled dose) of different PM fractions: other airborne pollutants, although harmful to human health, are less represented in studies of this type: for this reason, future studies should be conducted, also considering other air pollutants, not neglecting the assessment of exposure to PM. Moreover, many studies have been conducted indoors, where the population spends most of their daily time. However, it has been highlighted how particular environments, even if characterized by a shorter residence time, can contribute significantly to the dose of inhaled pollutants. These environments are, therefore, of particular importance and should be better evaluated in future studies, as well as occupational environments, where the work results in a high pulmonary ventilation rate. The attention of future studies should also be focused on these categories of subjects and occupational studies.

8.
Nanomaterials (Basel) ; 11(2)2021 Feb 05.
Article in English | MEDLINE | ID: mdl-33562871

ABSTRACT

In this study, the occupational risk assessment of carbon nanotubes (CNTs) was performed by means of a probabilistic approach. Chronic and subchronic inhalation exposure studies were retrieved during the hazard identification phase of the study. These studies were then used to obtain a guidance value (BMCh, expressed as a lognormal distribution with geometric mean ± geometric standard deviation = 10.0 ± 4.2 µg/m3) for occupational inhalation exposure to CNTs. An exposure scenario was selected from the scientific literature: three different work events (WEs) related to the production of conductive films were considered: (WE1) manufacturing of single walled carbon nanotubes films during normal operation using local exhaust ventilation (LEV); (WE2) manufacturing of SWCNT film without LEV; and (WE3) cleaning of one of the reactors. For each WE, a probability distribution function was applied, considering exposure expressed as mass concentration, as derived from three different measurement techniques. The ratio of the exposure and the BMCh distributions (i.e., the risk characterization ratio-RCR) was used to calculate the probability of occurrence of a relevant occupational risk. All the considered WEs indicated the presence of a risk (i.e., RCR distributions ≥ 1); however, only WE2 resulted in a statistically significant level of risk.

9.
Article in English | MEDLINE | ID: mdl-32825416

ABSTRACT

During rush hours, commuters are exposed to high concentrations and peaks of traffic-related air pollutants. The aims of this study were therefore to extend the inhaled dose estimation outcomes from a previous work investigating the inhaled dose of a typical commuter in the city of Milan, Italy, and to extend these results to a wider population. The estimation of the dose of pollutants inhaled by commuters and deposited within the respiratory tract could be useful to help commuters in choosing the modes of transport with the lowest exposure and to increase their awareness regarding this topic. In addition, these results could provide useful information to policy makers, for the creation/improvement of a mobility that takes these results into account. The principal result outcomes from the first part of the project (case study on a typical commuter in the city of Milan) show that during the winter period, the maximum deposited mass values were estimated in the "Other" environments and in "Underground". During the summer period, the maximum values were estimated in the "Other" and "Walking (high-traffic conditions)" environments. For both summer and winter, the lowest values were estimated in the "Car" and "Walking (low-traffic conditions)" environments. Regarding the second part of the study (the extension of the results to the general population of commuters in the city of Milan), the main results show that the period of permanence in a given micro-environment (ME) has an important influence on the inhaled dose, as well as the pulmonary ventilation rate. In addition to these results, it is of primary importance to report how the inhaled dose of pollutants can be strongly influenced by the time spent in a particular environment, as well as the subject's pulmonary ventilation rate and pollutant exposure levels. For these reasons, the evaluation of these parameters (pulmonary ventilation rate and permanence time, in addition to the exposure concentration levels) for estimating the inhaled dose is of particular relevance.


Subject(s)
Air Pollutants , Air Pollution , Environmental Pollutants , Air Pollutants/analysis , Air Pollution/analysis , Cities , Environmental Exposure/analysis , Humans , Inhalation Exposure , Italy , Particulate Matter/analysis , Transportation
10.
Article in English | MEDLINE | ID: mdl-32858967

ABSTRACT

As part of the assessment and management of chemical risk and occupational hygiene, retrospective exposure assessment (REA) to chemical agents can be defined as the estimate of exposure associated with a person's work history. The fundamental problem underlying the reconstruction of the exposure is that of transforming this type of information in quantitative terms to obtain an accurate estimate. REA can follow various approaches, some of which are technically complicated and both time and resource consuming. The aim of this systematic review is to present the techniques mainly used for occupational REA. In order to carry out this evaluation, a systematic review of the scientific literature was conducted. Forty-four studies were identified (published from 2010 to date) and analyzed. In exposure reconstruction studies, quantitative approaches should be preferable, especially when estimates will be used in the context of health impact assessment or epidemiology, although it is important to stress how, ideally, the experimental data available for the considered scenario should be used whenever possible as the main starting information base for further processing. To date, there is no single approach capable of providing an accurate estimate of exposure for each reasonably foreseeable condition and situation and the best approach generally depends on the level of information available for the specific case. The use of a combination of different reconstruction techniques can, therefore, represent a powerful tool for weighting and integrating data obtained through qualitative and quantitative approaches, in order to obtain the best possible estimate.


Subject(s)
Inhalation Exposure/analysis , Occupational Exposure/adverse effects , Occupational Health , Risk Assessment/methods , Asbestos/adverse effects , Environmental Monitoring , Humans , Prohibitins
11.
Article in English | MEDLINE | ID: mdl-32408600

ABSTRACT

Several studies evaluating exposure to pollutants in microenvironments (MEs) are available in the scientific literature, but studies that evaluate the inhaled doses of pollutants are few in number. Therefore, this study aimed to evaluate the exposure of commuters to different pollutants (i.e., nitrogen dioxide [NO2] and fractionated particulate matter [PM], including ultrafine particles [UFPs]) using miniaturized and portable real-time monitoring instruments in selected MEs; the inhaled doses of these pollutants were estimated for each of these MEs. Measurements were performed along a typical commute, considering different traffic and nontraffic MEs. Experimental data were collected over four working weeks in two different seasons (winter and summer). Different portable and miniaturized instruments were used to evaluate PM and NO2 exposure. Furthermore, physiological parameters were evaluated using a heart rate monitor. The principal results show that higher exposure levels were measured in Underground (for all PM fractions and NO2) and in Car (UFP), while lower levels were measured in Car (PM and NO2) and in Train (UFP). In contrast, higher values of the inhaled cumulative dose were estimated in environments defined as Other, followed by Walking (ht), while lower values were observed in Walking (lt) and in Car.


Subject(s)
Air Pollutants , Environmental Exposure , Environmental Pollutants , Environmental Monitoring , Humans , Nitrogen Dioxide , Particle Size , Particulate Matter , Transportation
12.
Article in English | MEDLINE | ID: mdl-31382456

ABSTRACT

Evaluation and validation studies of quantitative exposure models for occupational exposure assessment are still scarce and generally only consider a limited number of exposure scenarios. The aim of this review was to report the current state of knowledge of models' reliability in terms of precision, accuracy, and robustness. A systematic review was performed through searches of major scientific databases (Web of Science, Scopus, and PubMed), concerning reliability of Tier1 ("ECETOC TRA"-European Centre for Ecotoxicology and Toxicology of Chemicals Targeted Risk Assessment, MEASE, and EMKG-Expo-Tool) and Tier2 models (STOFFENMANAGER® and "ART"-Advanced Registration, Evaluation, Authorization and Restriction of Chemicals (REACH) Tool). Forty-five studies were identified, and we report the complete information concerning model performance in different exposure scenarios, as well as between-user reliability. Different studies describe the ECETOC TRA model as insufficient conservative to be a Tier1 model, in different exposure scenarios. Contrariwise, MEASE and EMKG-Expo-Tool seem to be conservative enough, even if these models have not been deeply evaluated. STOFFENMANAGER® resulted the most balanced and robust model. Finally, ART was generally found to be the most accurate and precise model, with a medium level of conservatism. Overall, the results showed that no complete evaluation of the models has been conducted, suggesting the need for correct and harmonized validation of these tools.


Subject(s)
Environmental Monitoring/methods , Occupational Exposure/analysis , Humans , Reproducibility of Results , Risk Assessment/methods
SELECTION OF CITATIONS