Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 35
Filter
1.
Arch Cardiovasc Dis ; 116(8-9): 366-372, 2023.
Article in English | MEDLINE | ID: mdl-37573160

ABSTRACT

BACKGROUND: Cardiac magnetic resonance imaging may provide a non-invasive alternative to coronary angiography for differentiating between ischaemic and non-ischaemic cardiomyopathy in cases of unexplained reduced left ventricular ejection fraction. AIM: The CAMAREC study aims to evaluate the diagnostic accuracy of cardiac magnetic resonance imaging in predicting significant coronary artery disease in patients with reduced left ventricular ejection fraction, using coronary angiography as the gold standard for comparison. METHODS: CAMAREC is a prospective cohort study of 406 patients in 10 centres with newly diagnosed, unexplained left ventricular ejection fraction ≤ 45%. Cardiac magnetic resonance imaging and coronary angiography will be conducted within a 2-week interval, starting with cardiac magnetic resonance imaging; independent committees will review the results blindly. Primary outcome is sensitivity of detecting ischaemic scar on cardiac magnetic resonance imaging for predicting significant coronary artery disease on coronary angiography according to Felker's criteria. Secondary outcomes include specificity and positive and negative predictive values (with 95% confidence intervals) of cardiac magnetic resonance imaging for predicting significant coronary artery disease in patients with reduced left ventricular ejection fraction, kappa concordance coefficient between cardiac magnetic resonance imaging and coronary angiography for diagnosing the affected myocardial territory, and the impact of cardiac magnetic resonance imaging on revascularization decisions. Two ancillary studies will evaluate the incremental cost-effectiveness of using cardiac magnetic resonance imaging first versus coronary angiography first, and the sensitivity of pre- and postcontrast T1-mapping for predicting significant coronary artery disease in patients with reduced left ventricular ejection fraction. CONCLUSION: Our study protocol is designed to rigorously evaluate cardiac magnetic resonance imaging as a non-invasive alternative to coronary angiography in patients with unexplained reduced left ventricular ejection fraction. The results will have significant implications for patient management, and may support growing evidence for the clinical utility of cardiac magnetic resonance imaging.


Subject(s)
Coronary Artery Disease , Ventricular Dysfunction, Left , Humans , Coronary Artery Disease/diagnosis , Stroke Volume , Prospective Studies , Ventricular Function, Left , Ventricular Dysfunction, Left/diagnostic imaging , Ventricular Dysfunction, Left/etiology , Magnetic Resonance Imaging
2.
J Clin Med ; 12(4)2023 Feb 11.
Article in English | MEDLINE | ID: mdl-36835980

ABSTRACT

BACKGROUND: Because rotational atherectomy (RA) is associated with arterial trauma and platelet activation, patients treated with RA may benefit from more potent antiplatelet drugs. The aim of this trial was to assess the superiority of ticagrelor over clopidogrel in reducing post procedure troponin release. METHODS: TIRATROP (TIcagrelor in Rotational Atherectomy to reduce TROPonin enhancement) is a multicenter double-blind randomized controlled trial that included 180 patients with severe calcified lesions requiring RA who received either clopidogrel (300 mg loading dose, then 75 mg/d) or ticagrelor (loading dose 180 mg then 90 mg twice daily). Blood samples were collected at the beginning (T0), and 6, 12, 18, 24 and 36 h after the procedure. Primary end point was troponin release within the first 24 h using area under the curve analysis (troponin level as a function of time). RESULTS: The mean age of patients was 76 ± 10 years, 35% had diabetes. RA was used to treat 1, 2 or 3 calcified lesions in 72%, 23% and 5% of patients, respectively. Troponin release within the first 24 h was similar in both the ticagrelor (adjusted mean ±SD of ln AUC 8.85 ± 0.33) and the clopidogrel (8.77 ± 0.34, p = 0.60) arms. Independent predictors for troponin enhancement were acute coronary syndrome presentation, renal failure, elevated C-Reactive protein and multiple lesions treated with RA. CONCLUSION: Troponin release did not differ among treatment arms. Our results suggest that greater platelet inhibition does not affect periprocedural myocardial necrosis in the setting of RA.

3.
Int J Cardiol ; 365: 106-111, 2022 10 15.
Article in English | MEDLINE | ID: mdl-35870637

ABSTRACT

BACKGROUND: Intravascular lithotripsy (IVL) is a promising new technology for disrupting de-novo calcified coronary lesions (DNL) before percutaneous coronary intervention (PCI). We assessed 12-month outcomes of IVL in patients undergoing PCI for DNL or intra stent restenosis (ISR) lesions related to device underexpansion. METHODS: Prospective analysis of patients in the multicentre all-comers French Shock Initiative IVL registry. The primary safety endpoints in this analysis were in-hospital and 12-month major adverse cardiovascular events (MACE: cardiac death, myocardial infarction or target vessel revascularization). The primary effectiveness endpoint was procedural success, defined as <30% residual stenosis without severe angiographic complications. Event rates were analysed for the cohort and for DNL and ISR procedures separately. RESULTS: A total of 220 lesions were treated (76.7% DNL and 23.3% ISR) in 202 patients. Procedural success was achieved in 95.5% of patients (DNL group: 96.5%; ISR group: 92.0%). In-hospital MACE occurred in 6.4% of cases, mainly driven by periprocedural infarctions. The rate of MACE-free survival at 1 year was 86.6% in the overall cohort. Rates of target vessel (TVR) and lesion (TLR) revascularisation were 6.4% and 2.5%, respectively. The 1-year MACE rate was 91.5% in DNL group and 83.8% in ISR group. CONCLUSIONS: In this large all-comers IVL cohort, rates of in-hospital and 1-year MACE were moderate. The safety and efficiency of IVL was comparable in DNL and ISR lesions. A comparative study of the impact of IVL on outcomes appears warranted.


Subject(s)
Coronary Restenosis , Lithotripsy , Percutaneous Coronary Intervention , Constriction, Pathologic , Coronary Angiography/adverse effects , Coronary Restenosis/diagnostic imaging , Coronary Restenosis/epidemiology , Coronary Restenosis/etiology , Humans , Lithotripsy/adverse effects , Stents/adverse effects , Treatment Outcome
4.
JACC Case Rep ; 2(15): 2394-2396, 2020 Dec.
Article in English | MEDLINE | ID: mdl-34317178

ABSTRACT

We report the case of an extended pseudo-subarachnoid hemorrhage (PSAH) related to contrast intracerebral diffusion from blood-brain barrier breakdown on periprocedural percutaneous coronary intervention right corticofrontal ischemic stroke. PSAH is a rare and complex phenomenon, and it is important to differentiate PSAH from subarachnoid hemorrhage to avoid inappropriate treatment with potentially severe consequences. (Level of Difficulty: Beginner.).

5.
Am Heart J ; 214: 97-106, 2019 08.
Article in English | MEDLINE | ID: mdl-31181374

ABSTRACT

The increased use of reperfusion therapy in ST-segment-elevation myocardial infarction (STEMI) patients in the past decades is generally considered the main determinant of improved outcomes. The aim was to assess 20-year trends in profile, management, and one-year outcomes in STEMI patients in relation with use or non-use of reperfusion therapy (primary percutaneous coronary intervention (pPCI) or fibrinolysis). METHODS: We used data from 5 one-month French nationwide registries, conducted 5 years apart from 2005 to 2015, including 8579 STEMI patients (67% with and 33% without reperfusion therapy) admitted to cardiac intensive care units in France. RESULTS: Use of reperfusion therapy increased from 49% in 1995 to 82% in 2015, with a shift from fibrinolysis (37.5% to 6%) to pPCI (12% to 76%). Early use of evidence-based medications gradually increased over the period in both patients with and without reperfusion therapy, although it remained lower at all times in those without reperfusion therapy. One-year mortality decreased in patients with reperfusion therapy (from 11.9% in 1995 to 5.9% in 2010 and 2015, hazard ratio [HR] adjusted on baseline profile 0.40; 95% CI: 0.29-0.54, P < .001) and in those without reperfusion therapy (from 25.0% to 18.2% in 2010 and 8.1% in 2015, HR: 0.33; 95% CI: 0.24-0.47, P < .001). CONCLUSIONS: In STEMI patients, one-year mortality continues to decline, both related to increased use of reperfusion therapy and progress in overall patient management. In patients with reperfusion therapy, mortality has remained stable since 2010, while it has continued to decline in patients without reperfusion therapy.


Subject(s)
Fibrinolytic Agents/therapeutic use , Myocardial Reperfusion/trends , Percutaneous Coronary Intervention/trends , ST Elevation Myocardial Infarction/therapy , Female , France , Humans , Male , Middle Aged , Mortality/trends , Myocardial Reperfusion/mortality , Percutaneous Coronary Intervention/mortality , Registries , ST Elevation Myocardial Infarction/mortality , Sex Factors , Time Factors , Time-to-Treatment/statistics & numerical data , Time-to-Treatment/trends , Treatment Outcome
6.
EuroIntervention ; 13(17): 2047-2050, 2018 04 20.
Article in English | MEDLINE | ID: mdl-28923786

ABSTRACT

AIMS: Long-term data on bioabsorbable polymer-coated everolimus-eluting stents (BP-EES) are limited. The EVOLVE trial compared the safety and efficacy of two dose formulations of the SYNERGY BP-EES with the permanent polymer-coated PROMUS Element EES (PE). METHODS AND RESULTS: The EVOLVE study was a prospective, multicentre, non-inferiority trial that randomised 291 patients with de novo coronary lesions (length: ≤28 mm; diameter: ≥2.25 to ≤3.5 mm) to receive PE (n=98), SYNERGY (n=94), or SYNERGY half-dose (n=99). At five years, there were no significant differences in the rates of TLF or individual components between groups. TLR rates trended lower in both SYNERGY arms than in the PE arm (TLR: 1.1% SYNERGY and 1.0% SYNERGY half-dose vs. 6.1% PE; p=0.07 and p=0.06, respectively). TVR was numerically lower in the SYNERGY arms compared to the PE arm (TVR: 3.3% SYNERGY and 4.2% SYNERGY half-dose vs. 10.2% PE; p=0.06 and p=0.11, respectively). No incidence of stent thrombosis was reported in any arm up to five years. CONCLUSIONS: The EVOLVE trial represents the longest-term follow-up of the SYNERGY stent available to date, demonstrating its continued safety and efficacy for the treatment of selected de novo atherosclerotic lesions up to five years.


Subject(s)
Absorbable Implants/adverse effects , Coronary Artery Disease , Coronary Restenosis , Everolimus/pharmacology , Long Term Adverse Effects , Percutaneous Coronary Intervention , Aged , Coronary Artery Disease/diagnosis , Coronary Artery Disease/surgery , Coronary Restenosis/diagnosis , Coronary Restenosis/epidemiology , Coronary Restenosis/etiology , Drug-Eluting Stents , Female , Follow-Up Studies , Humans , Immunosuppressive Agents/pharmacology , Long Term Adverse Effects/diagnosis , Long Term Adverse Effects/epidemiology , Long Term Adverse Effects/etiology , Male , Middle Aged , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/instrumentation , Percutaneous Coronary Intervention/methods , Polymers/pharmacology , Prosthesis Design , Treatment Outcome
7.
JACC Cardiovasc Interv ; 10(23): 2392-2400, 2017 12 11.
Article in English | MEDLINE | ID: mdl-29217001

ABSTRACT

OBJECTIVES: The authors sought to evaluate the final 5-year safety and effectiveness of the platinum-chromium everolimus-eluting stent (PtCr-EES) in the randomized trial, as well as in 2 single-arm substudies that evaluated PtCr-EES in small vessels (diameter <2.5 mm; n = 94) and long lesions (24 to 34 mm; n = 102). BACKGROUND: In the multicenter, randomized PLATINUM (PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of De Novo Coronary Artery Lesions), the PtCr-EES was noninferior to the cobalt-chromium everolimus-eluting stent (CoCr-EES) at 1 year in 1,530 patients undergoing percutaneous coronary intervention. METHODS: Patients with 1 or 2 de novo coronary artery lesions (reference vessel diameter 2.50 to 4.25 mm, length ≤24 mm) were randomized 1:1 to PtCr-EES versus CoCr-EES. All patients in the substudies received PtCr-EES. The primary endpoint was target lesion failure (TLF), a composite of target vessel-related cardiac death, target vessel-related myocardial infarction, or ischemia-driven target lesion revascularization. RESULTS: In the randomized trial, the 5-year TLF rate was 9.1% for PtCr-EES and 9.3% for CoCr-EES (hazard ratio [HR]: 0.97; p = 0.87). Landmark analysis demonstrated similar TLF rates from discharge to 1 year (HR: 1.12; p = 0.70) and from 1 to 5 years (HR: 0.90; p = 0.63). There were no significant differences in the rates of cardiac death, myocardial infarction, target lesion or vessel revascularization, or stent thrombosis. PtCr-EES had 5-year TLF rates of 7.0% in small vessels and 13.6% in long lesions. CONCLUSIONS: PtCr-EES demonstrated comparable safety and effectiveness to CoCr-EES through 5 years of follow-up, with low rates of stent thrombosis and other adverse events. The 5-year event rates were also acceptable in patients with small vessels and long lesions treated with PtCr-EES. (The PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of De Novo Coronary Artery Lesions [PLATINUM]; NCT00823212; The PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of De Novo Coronary Artery Lesions in Small Vessels [PLATINUM SV]; NCT01498692; The PLATINUM Clinical Trial to Assess the PROMUS Element Stent System for Treatment of Long De Novo Coronary Artery Lesions [PLATINUM LL]; NCT01500434).


Subject(s)
Cardiovascular Agents/administration & dosage , Chromium Alloys , Coronary Artery Disease/therapy , Drug-Eluting Stents , Everolimus/administration & dosage , Percutaneous Coronary Intervention/instrumentation , Platinum , Aged , Asia , Cardiovascular Agents/adverse effects , Coronary Artery Disease/diagnostic imaging , Coronary Artery Disease/mortality , Coronary Thrombosis/etiology , Europe , Everolimus/adverse effects , Female , Humans , Kaplan-Meier Estimate , Male , Middle Aged , Myocardial Infarction/etiology , Percutaneous Coronary Intervention/adverse effects , Percutaneous Coronary Intervention/mortality , Proportional Hazards Models , Prosthesis Design , Risk Factors , Time Factors , Treatment Outcome , United States
8.
Arch Cardiovasc Dis ; 110(6-7): 366-378, 2017.
Article in English | MEDLINE | ID: mdl-28647465

ABSTRACT

BACKGROUND: The FAST-MI programme, consisting of 1-month surveys of patients admitted to hospital for acute myocardial infarction (AMI) in France, has run since 2005. AIM: To gather data on the characteristics, management and outcomes of patients hospitalized for AMI at the end of 2015 in France and to provide comparisons with the previous surveys. METHODS: Consecutive adults with ST-segment elevation myocardial infarction (STEMI) or non-ST-segment-elevation myocardial infarction (NSTEMI) with symptom onset≤48hours were included over a 1-month period, with a possible extension of recruitment for 1 additional month. Patients with AMI following cardiovascular procedures were excluded. In all, 204 centres participated in the survey (114 community hospitals, 40 academic, 48 private clinics, 2 army hospitals), representing 78% of French centres managing AMI patients. Inclusion started from 5 October 2015. Data were collected on-site from source files by external research technicians, using an electronic case record form with automatic quality checks. Centralized biology was organized in voluntary centres to collect RNA and DNA samples, serum and stools. Long-term follow-up was organized centrally with interrogation of municipal registry offices, physicians and by direct contact with the patients or their families. RESULTS: A total of 5291 patients were included over the entire recruitment period, with 3813 included during the first month (STEMI: 49%, NSTEMI: 51%). Mean age was 66±14 years, 29% were≥75 years of age, 28% were women; 80% presented with typical chest pain. In STEMI patients, 6% received intravenous fibrinolysis and 71% underwent primary PCI. The hospital death rate was 2.7% (STEMI: 2.8%, NSTEMI: 2.5%). CONCLUSIONS: Recruitment was in line with expectations and the first data show that management has continued to evolve since the 2010 survey, with continued improvement in hospital outcomes.


Subject(s)
Non-ST Elevated Myocardial Infarction/epidemiology , Registries , Research Design , ST Elevation Myocardial Infarction/epidemiology , Aged , Aged, 80 and over , Cardiovascular Agents/therapeutic use , Comorbidity , Data Accuracy , Female , France/epidemiology , Hospital Mortality , Hospitalization , Humans , Male , Middle Aged , Non-ST Elevated Myocardial Infarction/diagnosis , Non-ST Elevated Myocardial Infarction/mortality , Non-ST Elevated Myocardial Infarction/therapy , Patient Selection , Percutaneous Coronary Intervention , Prospective Studies , Risk Factors , ST Elevation Myocardial Infarction/diagnosis , ST Elevation Myocardial Infarction/mortality , ST Elevation Myocardial Infarction/therapy , Thrombolytic Therapy , Time Factors , Treatment Outcome
9.
Catheter Cardiovasc Interv ; 88(3): 397-406, 2016 Sep.
Article in English | MEDLINE | ID: mdl-27143281

ABSTRACT

Bioresorbable vascular scaffolds have been recently introduced as a novel paradigm for coronary artery disease treatment allowing temporary vessel support and drug delivery without indefinite coronary caging, potentially reducing the long-term limitation of metallic stents. The scientific community has rapidly embraced this concept and bioresorbable devices have been introduced in clinical practice. However, despite the fact that bifurcation lesions represent a large and challenging subset in the field of interventional cardiology, this subgroup of lesions have been avoided in the initial experience with bioresorbable scaffolds and clear recommendations on methodological approaches are lacking. In the present report, we describe the various techniques for bifurcation treatment with bioresorbable scaffolds and the theoretical advantages and disadvantages of this technology in different scenarios, with a glimpse to challenging subsets and possible complications. Therefore, we aim to provide experience based insights and practical guidance for bioresorbable scaffold implantation in bifurcation lesions. © 2016 Wiley Periodicals, Inc.


Subject(s)
Absorbable Implants , Angioplasty, Balloon, Coronary/instrumentation , Coronary Artery Disease/therapy , Stents , Angioplasty, Balloon, Coronary/adverse effects , Angioplasty, Balloon, Coronary/methods , Coronary Angiography , Coronary Artery Disease/diagnostic imaging , Humans , Predictive Value of Tests , Prosthesis Design , Risk Factors , Tomography, Optical Coherence , Treatment Outcome , Ultrasonography, Interventional
11.
JACC Cardiovasc Interv ; 7(10): 1138-45, 2014 Oct.
Article in English | MEDLINE | ID: mdl-25240554

ABSTRACT

OBJECTIVES: The aim of this study was to analyze the incidence, impact, and predictors of cerebrovascular events (CVEs) in patients undergoing transcatheter aortic valve replacement (TAVR). BACKGROUND: Several issues remain unresolved post-TAVR, including CVEs. METHODS: The FRANCE-2 (French Aortic Nation CoreValve and Edwards-2) registry prospectively included all patients who underwent TAVR in France and Monaco from January 2010 to October 2011. A total of 3,191 patients were analyzed. Six-month follow-up data were obtained. Events were adjudicated according to Valve Academic Research Consortium (VARC)-1 definition. RESULTS: Of the cohort, 3.98% experienced a CVE: 55% were major strokes, 14.5% minor strokes, and 30.5% transient ischemic attacks. The mean delay for CVE occurrence was 2 days (interquartile range: 0 to 7 days) with 48.5% of CVEs occurring within 2 days. There was no statistically significant difference in CVE rate with regard to the type of valve (p = 0.899) and the access route (p = 0.128). Patients with a CVE more frequently had new-onset paroxysmal atrial fibrillation (13.6% vs. 7.6%; p = 0.015). During follow-up, the unadjusted mortality rate was higher in patients with a CVE (26% vs. 16.5%; p = 0.002). By multivariate analysis, only advanced age (odds ratio: 1.05; 95% confidence interval: 1.02 to 1.08; p = 0.02) and having 2 valves implanted (odds ratio: 3.13; 95 confidence interval: 1.40 to 7.05; p = 0.006) were associated with a significant risk of CVEs. CONCLUSIONS: CVEs occur frequently after TAVR and are associated with an increased mortality rate. No difference exists in the CVE rate when exploring the type of valve or the access route. Advanced age and multiple valves implanted during the same procedure are predictors of CVE.


Subject(s)
Aortic Valve Stenosis/therapy , Cardiac Catheterization/adverse effects , Heart Valve Prosthesis Implantation/adverse effects , Ischemic Attack, Transient/epidemiology , Stroke/epidemiology , Age Factors , Aged , Aged, 80 and over , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/mortality , Atrial Fibrillation/epidemiology , Cardiac Catheterization/methods , Cardiac Catheterization/mortality , Female , France/epidemiology , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Humans , Incidence , Ischemic Attack, Transient/diagnosis , Ischemic Attack, Transient/mortality , Kaplan-Meier Estimate , Logistic Models , Male , Monaco/epidemiology , Multivariate Analysis , Odds Ratio , Registries , Risk Factors , Severity of Illness Index , Stroke/diagnosis , Stroke/mortality , Time Factors , Treatment Outcome
12.
J Invasive Cardiol ; 25(12): 680-2, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24296390

ABSTRACT

An 85-year-old woman was admitted to our institution for effort dyspnea. She had a history of mitral valve replacement with a 29 mm Carpentier-Edwards bioprosthesis (Edwards Lifesciences). Transthoracic echocardiography (TTE) showed aortic stenosis and senescence of the mitral bioprosthesis. The heart team opted for a transapical transcatheter aortic valve implantation (TAVI) and mitral valve-in-valve implantation (m-ViV). Two Edwards Sapien XT (ESXT) 29 mm devices were selected. To our knowledge, this is the first description of the concomitant transapical implantation of two 29 mm ESXTs for a combination of failed mitral bioprosthesis and native aortic stenosis.


Subject(s)
Aortic Valve Stenosis/surgery , Aortic Valve/surgery , Bioprosthesis/classification , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis/classification , Mitral Valve/surgery , Prosthesis Failure , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve Stenosis/diagnostic imaging , Comorbidity , Echocardiography, Transesophageal , Female , Heart Murmurs/diagnostic imaging , Heart Murmurs/etiology , Heart Murmurs/surgery , Heart Valve Diseases/diagnostic imaging , Heart Valve Diseases/etiology , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation/methods , Humans , Mitral Valve/diagnostic imaging , Prosthesis Failure/adverse effects , Treatment Outcome
13.
J Am Coll Cardiol ; 61(8): 830-6, 2013 Feb 26.
Article in English | MEDLINE | ID: mdl-23333140

ABSTRACT

OBJECTIVES: The aim of this study was to compare outcomes after transfemoral transcatheter aortic valve implantation with the Medtronic CoreValve (MCV) versus the Edwards SAPIEN/SAPIEN XT transcatheter heart valve (ESV) for severe aortic stenosis. BACKGROUND: No large matched comparison study has been conducted so far evaluating both commercially available devices. METHODS: The data from databases of 4 experienced European centers were pooled and analyzed. Due to differences in baseline clinical characteristics, propensity score matching was performed. Study objectives were Valve Academic Research Consortium outcomes at 30 days and 1 year. RESULTS: In total, 793 patients were included: 453 (57.1%) treated with the MCV and 340 (42.9%) with the ESV. After propensity matching, 204 patients were identified in each group. At 30 days, there were no differences in all-cause mortality (MCV, 8.8% vs. ESV, 6.4%; hazard ratio [HR]: 1.422; 95% confidence interval [CI]: 0.677 to 2.984; p = 0.352), cardiovascular mortality (MCV, 6.9% vs. ESV, 6.4%; HR: 1.083; 95% CI: 0.496 to 2.364; p = 0.842), myocardial infarction (MCV, 0.5% vs. ESV, 1.5%; HR: 0.330; 95% CI: 0.034 to 3.200; p = 0.339), stroke (MCV, 2.9% vs. ESV, 1.0%; HR: 3.061; 95% CI: 0.610 to 15.346; p = 0.174), or device success (MCV, 95.6% vs. ESV, 96.6%; HR: 0.770; 95% CI: 0.281 to 2.108; p = 0.611). Additionally, there were no differences in major vascular complications (MCV, 9.3% vs. ESV, 12.3%; HR: 0.735; 95% CI: 0.391 to 1.382; p = 0.340) or life-threatening bleeding (MCV, 13.7% vs. ESV, 8.8%; HR: 1.644; 95% CI: 0.878 to 3.077; p = 0.120). MCV was associated with more permanent pacemakers (22.5% vs. 5.9%; HR: 4.634; 95% CI: 2.373 to 9.050; p < 0.001). At 1 year, there were no differences in all-cause (MCV, 16.2% vs. ESV, 12.3%; HR: 1.374; 95% CI: 0.785 to 2.407; p = 0.266) or cardiovascular (MCV, 8.3% vs. ESV, 7.4%; HR: 1.145; 95% CI: 0.556 to 12.361; p = 0.713) mortality. CONCLUSIONS: No differences between the 2 commercially available transfemoral transcatheter aortic valve implantation devices were observed at the adjusted analysis in Valve Academic Research Consortium outcomes except for the need for permanent pacemakers with the MCV.


Subject(s)
Aortic Valve Stenosis/surgery , Cardiac Catheterization/methods , Heart Valve Prosthesis Implantation , Heart Valve Prosthesis , Postoperative Complications/epidemiology , Prosthesis Design , Vascular Diseases , Aged , Aged, 80 and over , Aortic Valve/surgery , Aortic Valve Stenosis/diagnosis , Aortic Valve Stenosis/physiopathology , Comparative Effectiveness Research , Female , Heart Function Tests , Heart Valve Prosthesis/adverse effects , Heart Valve Prosthesis/statistics & numerical data , Heart Valve Prosthesis Implantation/adverse effects , Heart Valve Prosthesis Implantation/instrumentation , Heart Valve Prosthesis Implantation/methods , Heart Valve Prosthesis Implantation/mortality , Humans , Male , Outcome Assessment, Health Care , Product Surveillance, Postmarketing , Propensity Score , Retrospective Studies , Severity of Illness Index , Survival Analysis , Survival Rate , Vascular Diseases/epidemiology , Vascular Diseases/etiology
14.
EuroIntervention ; 8(5): 556-62, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22995081

ABSTRACT

AIMS: High rates of permanent pacemaker (PPM) implantation are reported after transcatheter aortic valve implantation (TAVI) using the Medtronic CoreValve® system. The Accutrak™ catheter is designed to allow a more predictable landing zone. Little is known about the real clinical impact of this catheter. The aims of this paper were to describe the potential impact of the Accutrak™ catheter on the accuracy of positioning a 26 or 29 mm CoreValve® across the aortic annulus and its impact on the need for a pacemaker. METHODS AND RESULTS: A total of 134 patients were treated with the CoreValve® Accutrak™ system at two French centres (Lille and Toulouse). Mean age was 82.4 ± 4.7 years; logistic EuroSCORE was 24.3 ± 9.5%. Procedural success rate was 99.2%; mean depth of implantation was 4.9 mm. A final position between 0 and 6 mm was achieved in 85.8% of the patients. All-cause mortality at 30 days was 6%. The PPM implantation rate was 10.6%. Due to a limited number of events, we could not identify any predictor of need for a PPM: pre-existing right bundle branch block (RBBB) (OR 2.72 [0.63-11.87], p=ns), use of a 29 mm prosthesis (OR 2.73 [0.33-22.90], p=ns) and left ventricular septal hypertrophy (OR 2.63 [0.08-83.32], p=ns). CONCLUSIONS: In this cohort of patients treated with the CoreValve® Accutrak™ system, the incidence of permanent pacemaker implantation was low, which may be a consequence of an average small implantation depth. The Accutrak™ catheter seems to be helpful in achieving higher and more predictable implants. Operators could standardise their technique to place the CoreValve® prostheses less than 6 mm below the aortic annulus.


Subject(s)
Aortic Valve/surgery , Catheters , Heart Valve Prosthesis Implantation/methods , Pacemaker, Artificial , Aged , Aged, 80 and over , Cardiac Catheterization , Female , Heart Valve Prosthesis Implantation/instrumentation , Humans , Male , Treatment Outcome
15.
Am Heart J ; 164(3): 402-9, 2012 Sep.
Article in English | MEDLINE | ID: mdl-22980308

ABSTRACT

BACKGROUND: Little is known about the impact of bleeding and red blood cells transfusion (RBC) on the outcome post transcatheter aortic valve implantation (TAVI). METHODS: Between November 2005 and August 2011, 943 consecutive patients underwent TAVI. Bleeding was assessed according to the Valve Academic Research Consortium definitions. Patients receiving RBC were compared to those not requiring transfusion. RESULTS: Life-threatening and major bleedings occurred respectively in 13.9% and 20.9% of the patients, significantly more frequently in the RBC cohort. Vascular complications occurred in 23.2% of the patients. Major and minor vascular complications were more frequent in the RBC group: 19.3 vs 5.2%, P < .001; 15.3 vs 9%, P = .003, respectively. Thirty-day all-cause mortality was 7.2%. Of the overall cohort, 38.9% required RBC transfusion; those receiving at least 4 U of RBC had higher 30-day all-cause mortality than those receiving 1 to 4 U of RBC and those not requiring transfusion: 14.4%, vs 6.3% vs 6.3%, respectively, P = .008. By multivariate analysis, transfusion of RBC was associated with an increased 30-day and 1-year mortality. Major stroke and all stages of acute kidney injury were significantly more frequent in the RBC cohort. CONCLUSIONS: Bleeding is frequent after TAVI, mainly driven by vascular complications. RBC transfusion was associated with increased mortality at 1 year and increased risk of major stroke and acute kidney injury. Specific scores are needed to identify the patients at higher risk for TAVI-related bleeding and RBC transfusion.


Subject(s)
Erythrocyte Transfusion/adverse effects , Heart Defects, Congenital/surgery , Heart Valve Diseases/surgery , Heart Valve Prosthesis Implantation , Postoperative Hemorrhage/etiology , Acute Kidney Injury/etiology , Aged , Aged, 80 and over , Aortic Valve/surgery , Bicuspid Aortic Valve Disease , Cardiac Catheterization , Cohort Studies , Female , Heart Defects, Congenital/mortality , Heart Valve Diseases/mortality , Humans , Male , Postoperative Hemorrhage/diagnosis , Postoperative Hemorrhage/therapy , Retrospective Studies , Risk Factors , Stroke/etiology , Treatment Outcome
16.
Arch Cardiovasc Dis ; 105(5): 262-70, 2012 May.
Article in English | MEDLINE | ID: mdl-22709467

ABSTRACT

BACKGROUND: Guidelines emphasize the implementation of local networks with prehospital emergency medical systems to improve the management of patients with ST-segment elevation myocardial infarction (STEMI); they also define the choice of reperfusion strategies and adjunctive treatments. AIM: To assess the compliance of STEMI emergency care with current French guidelines in a large area of France and to identify predictors of compliance with guidelines. METHOD: The RESCA+31 registry was a 2-year, multicentre, prospective, multidisciplinary study, including 512 consecutive patients with STEMI evolving within 12 hours managed by emergency physicians in the prehospital system or emergency department. Data were recorded during the emergency phase and after admission to cardiology. RESULTS: First medical contact (FMC) was prehospital emergency care for 80% of patients; 97% received reperfusion treatment and 98% were admitted to a cardiology intensive care unit (CICU) with a catheterization laboratory. The mortality rate was 5%. Guidelines were complied with in 41% of patients for reperfusion strategies, in 47% for adjunctive treatments and in 23% for both. The only factor independently associated with guideline compliance was FMC by prehospital emergency system. In 52% of cases, emergency physicians underestimated the delay between FMC and admission to a CICU. CONCLUSION: Despite the implementation of a network, compliance with guidelines for reperfusion strategies and adjunctive treatments was insufficient in our area. However, very few patients did not receive reperfusion therapy and the mortality rate was low. Efforts should be made to improve the estimation of delay before primary percutaneous coronary intervention.


Subject(s)
Emergency Service, Hospital/standards , Guideline Adherence/standards , Myocardial Infarction/therapy , Myocardial Reperfusion/standards , Practice Guidelines as Topic/standards , Practice Patterns, Physicians'/standards , Aged , Angioplasty, Balloon, Coronary/standards , Cardiac Catheterization/standards , Chi-Square Distribution , Coronary Care Units/standards , Emergency Medical Services/standards , Female , France , Health Services Research , Humans , Logistic Models , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/mortality , Myocardial Reperfusion/adverse effects , Myocardial Reperfusion/mortality , Odds Ratio , Platelet Aggregation Inhibitors/therapeutic use , Prospective Studies , Registries , Thrombolytic Therapy/standards , Time Factors , Treatment Outcome
17.
EuroIntervention ; 7(9): 1069-76, 2012 Jan.
Article in English | MEDLINE | ID: mdl-21959084

ABSTRACT

AIMS: To compare the outcomes of drug-eluting (DES) vs. bare-metal (BMS) stents for stenting of native aorto-ostial lesions (AOL) and to identify predictors of major adverse cardio and cerebrovascular events (MACCE). METHODS AND RESULTS: A total of 181 patients (182 AOL) who underwent stenting of AOL were retrospectively identified: right-coronary artery in 130 (71.4%), left main in 52 (28.6%). In-hospital event rate was 1.1% (two non-Q-wave myocardial infarctions). Follow-up was possible in 98.3%, median time=23.9 months (IQR 12.1-37.7). Event rates and survival MACCE-free were not significantly different between DES and BMS. After multivariate analysis, only the logistic EuroSCORE >10% predicted MACCE (HR=4.66, 95% CI: 2.38-9.12, p<0.001), whereas the predictors for TLR were age (HR=0.96, 95% CI: 0.92-1.00, p=0.039) and the stented artery (RCA vs. LM, HR=10.2, 95% CI: 1.37-75.45, p=0.024). CONCLUSIONS: AOL stenting can be performed with high success and low complication rates. At follow-up, no significant differences in event rates were found between DES and BMS; EuroSCORE>10% was the only predictor of MACCE.


Subject(s)
Angioplasty/methods , Aortic Diseases/diagnosis , Aortic Diseases/therapy , Drug-Eluting Stents , Metals , Stents , Aged , Aged, 80 and over , Aortic Diseases/mortality , Female , Follow-Up Studies , Humans , Incidence , Longitudinal Studies , Male , Middle Aged , Multivariate Analysis , Myocardial Infarction/epidemiology , Prognosis , Proportional Hazards Models , Retrospective Studies , Stroke/epidemiology , Survival Rate , Treatment Outcome
18.
J Am Coll Cardiol ; 57(16): 1700-8, 2011 Apr 19.
Article in English | MEDLINE | ID: mdl-21470815

ABSTRACT

OBJECTIVES: We sought to evaluate the clinical outcomes with a novel platinum chromium everolimus-eluting stent (PtCr-EES) compared with a predicate cobalt chromium everolimus-eluting stent (CoCr-EES) in patients undergoing percutaneous coronary intervention (PCI). BACKGROUND: Randomized trials have demonstrated an excellent safety and efficacy profile for the CoCr-EES. The PtCr-EES uses the identical antiproliferative agent and polymer but with a novel platinum chromium scaffold designed for enhanced deliverability, vessel conformability, side-branch access, radiopacity, radial strength, and fracture resistance. METHODS: A total of 1,530 patients undergoing PCI of 1 or 2 de novo native lesions were randomized at 132 worldwide sites to CoCr-EES (n = 762) or PtCr-EES (n = 768). The primary endpoint was the 12-month rate of target lesion failure (TLF), the composite of target vessel-related cardiac death, target vessel-related myocardial infarction (MI), or ischemia-driven target lesion revascularization (TLR) in the per-protocol population (patients who received ≥1 assigned study stent), powered for noninferiority. RESULTS: The 12-month rate of TLF in the per-protocol population occurred in 2.9% versus 3.4% of patients assigned to CoCr-EES versus PtCr-EES, respectively (difference: 0.5%, 95% confidence interval: -1.3% to 2.3%, p(noninferiority) = 0.001, p(superiority) = 0.60). By intention-to-treat, there were no significant differences between CoCr-EES and PtCr-EES in the 12-month rates of TLF (3.2% vs. 3.5%, p = 0.72), cardiac death or MI (2.5% vs. 2.0%, p = 0.56), TLR (1.9% vs. 1.9%, p = 0.96), or Academic Research Consortium definite or probable stent thrombosis (0.4% vs. 0.4%, p = 1.00). CONCLUSIONS: In this large-scale, prospective, single-blind randomized trial, a novel PtCr-EES was noninferior to the predicate CoCr-EES for TLF, with nonsignificant differences in measures of safety and efficacy through 12-month follow-up after PCI.


Subject(s)
Coronary Artery Disease/drug therapy , Drug-Eluting Stents/trends , Sirolimus/analogs & derivatives , Aged , Coronary Artery Disease/physiopathology , Coronary Artery Disease/surgery , Drug-Eluting Stents/standards , Everolimus , Female , Follow-Up Studies , Humans , Male , Middle Aged , Prospective Studies , Single-Blind Method , Sirolimus/administration & dosage , Treatment Outcome
19.
Agora (Rio J.) ; 13(2): 293-295, dez. 2010.
Article in Portuguese | LILACS | ID: lil-567295
SELECTION OF CITATIONS
SEARCH DETAIL
...