Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Article in English | MEDLINE | ID: mdl-32580452

ABSTRACT

Artificial stone is increasing in popularity in construction applications, including commercial and residential countertops. Eco-friendliness, durability, and resistance to staining, make artificial stone attractive to consumers. Health concerns have arisen during manufacturing of artificial stone due to increased incidence of silicosis after relatively short exposure. Three artificial stone samples (A, B, and C) and one natural granite sample were subjected to cutting and grinding in a controlled environment. Gravimetric analysis, X-Ray diffraction, and scanning electron microscopy with energy dispersive spectroscopy were employed to determine crystalline silica concentrations and particle morphology of bulk and respirable particles. Silica content of bulk dust from artificial samples A and B was 91%, sample C was <10%, while granite was 31%. Silica percent in the respirable fraction for samples A and B was 53% and 54%, respectively, while sample C was <5% and granite was 8%. Number concentrations for samples A and B were mainly in the nano-fraction, indicating potential for translocation of silica particles to other organs outside of the lungs. Respirable dust concentrations inside the chamber were well above Occupational Safety and Health Administration standards for all materials, indicating that confined-space exposures require ventilation to lower risks of acute silicosis regardless of the nature of the stone.


Subject(s)
Air Pollutants, Occupational , Manufacturing and Industrial Facilities , Occupational Exposure , Silicon Dioxide , Silicosis , Air Pollutants, Occupational/toxicity , Dust , Humans , Inhalation Exposure , Silicon Dioxide/toxicity , Silicosis/epidemiology , Ventilation
2.
J Occup Med Toxicol ; 14: 10, 2019.
Article in English | MEDLINE | ID: mdl-30949228

ABSTRACT

BACKGROUND: Methicillin-resistant Staphylococcus aureus contamination on surfaces including turnout gear had been found throughout a number of fire stations. As such, the outer shell barrier of turnout gear jackets may be an indirect transmission source and proper disinfection is essential to reduce the risk of exposure to fire fighters. Cleaning practices vary considerably among fire stations, and a method to assess disinfection of gear washed in commercial washer/extractors is needed. METHODS: Swatches (1 in. ×  1.5 in.) of the outer shell fabrics, Gemini™, Advance™, and Pioneer™, of turnout gear were inoculated with S. aureus, and washed with an Environmental Protection Agency-registered sanitizer commonly used to wash turnout gear. To initially assess the sanitizer, inoculated swatches were washed in small tubes according to the American Society for Testing Materials E2274 Protocol for evaluating laundry sanitizers. Inoculated swatches were also pinned to turnout gear jackets and washed in a Milnor commercial washer/extractor. Viable S. aureus that remained attached to fabric swatches after washing were recovered and quantified. Scanning Electron Microscopy was used to characterize the stages of S. aureus biofilm formation on the swatches that can result in resistance to disinfection. RESULTS: Disinfection in small tubes for only 10 s reduced the viability of S. aureus on Gemini™, Advance™, and Pioneer™ by 73, 99, and 100%, respectively. In contrast, disinfection of S. aureus-contaminated Gemini™ swatches pinned to turnout gear and washed in the washer/extractor was 99.7% effective. Scanning Electron Microscopy showed that biofilm formation begins as early as 5 h after attachment of S. aureus. CONCLUSION: This sanitizer and, likely, others containing the anti-microbial agent didecyl dimethyl ammonium chloride, is an effective disinfectant of S. aureus. Inclusion of contaminated outer shell swatches in the wash cycle affords a simple and quantitative method to assess sanitization of gear by commercial gear cleaning facilities. This methodology can be extended to assess for other bacterial contaminants. Sanitizer-resistant strains will continue to pose problems, and biofilm formation may affect the cleanliness of the washed turnout gear. Our methodology for assessing effectiveness of disinfection may help reduce the occupational exposure to fire fighters from bacterial contaminants.

3.
J Occup Environ Hyg ; 13(11): D201-7, 2016 11.
Article in English | MEDLINE | ID: mdl-27314444

ABSTRACT

Rock dusting is used to prevent secondary explosions in coal mines, but inhalation of rock dusts can be hazardous if the crystalline silica (e.g., quartz) content in the respirable fraction is high. The objective of this study is to assess the quartz content and physical characteristics of four selected rock dusts, consisting of limestone or marble in both treated (such as treatment with stearic acid or stearates) and untreated forms. Four selected rock dusts (an untreated and treated limestone and an untreated and treated marble) were aerosolized in an aerosol chamber. Respirable size-selective sampling was conducted along with particle size-segregated sampling using a Micro-Orifice Uniform Deposit Impactor. Fourier Transform Infrared spectroscopy and scanning electron microscopy with energy-dispersive X-ray (SEM-EDX) analyses were used to determine quartz mass and particle morphology, respectively. Quartz percentage in the respirable dust fraction of untreated and treated forms of the limestone dust was significantly higher than in bulk samples, but since the bulk percentage was low the enrichment factor would not have resulted in any major change to conclusions regarding the contribution of respirable rock dust to the overall airborne quartz concentration. The quartz percentage in the marble dust (untreated and treated) was very low and the respirable fractions showed no enrichment. The spectra from SEM-EDX analysis for all materials were predominantly from calcium carbonate, clay, and gypsum particles. No free quartz particles were observed. The four rock dusts used in this study are representative of those presented for use in rock dusting, but the conclusions may not be applicable to all available materials.


Subject(s)
Coal Mining , Inhalation Exposure/analysis , Occupational Exposure/analysis , Quartz/analysis , Calcium Carbonate/chemistry , Dust , Humans , Microscopy, Electron, Scanning , Particle Size , Spectroscopy, Fourier Transform Infrared
4.
J Occup Environ Hyg ; 13(2): D16-22, 2016.
Article in English | MEDLINE | ID: mdl-26375614

ABSTRACT

The objective of this article is to compare and characterize nylon, polypropylene (PP), and polyvinyl chloride (PVC) membrane filters that might be used to replace the vinyl/acrylic co-polymer (DM-450) filter currently used in the Mine Safety and Health Administration (MSHA) P-7 method (Quartz Analytical Method) and the National Institute for Occupational Safety and Health (NIOSH) Manual of Analytical Methods 7603 method (QUARTZ in coal mine dust, by IR re-deposition). This effort is necessary because the DM-450 filters are no longer commercially available. There is an impending shortage of DM-450 filters. For example, the MSHA Pittsburgh laboratory alone analyzes annually approximately 15,000 samples according to the MSHA P-7 method that requires DM-450 filters. Membrane filters suitable for on-filter analysis should have high infrared (IR) transmittance in the spectral region 600-1000 cm(-1). Nylon (47 mm, 0.45 µm pore size), PP (47 mm, 0.45 µm pore size), and PVC (47 mm, 5 µm pore size) filters meet this specification. Limits of detection and limits of quantification were determined from Fourier transform infrared spectroscopy (FTIR) measurements of blank filters. The average measured quartz mass and coefficient of variation were determined from test filters spiked with respirable α-quartz following MSHA P-7 and NIOSH 7603 methods. Quartz was also quantified in samples of respirable coal dust on each test filter type using the MSHA and NIOSH analysis methods. The results indicate that PP and PVC filters may replace the DM-450 filters for quartz measurement in coal dust by FTIR. PVC filters of 5 µm pore size seemed to be suitable replacement although their ability to retain small particulates should be checked by further experiment.


Subject(s)
Air Pollutants, Occupational/analysis , Dust/analysis , Environmental Monitoring/instrumentation , Membranes, Artificial , Quartz/analysis , Coal Mining , Filtration/instrumentation , National Institute for Occupational Safety and Health, U.S. , Spectrophotometry, Infrared , United States
SELECTION OF CITATIONS
SEARCH DETAIL
...