Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
Add more filters










Database
Type of study
Publication year range
1.
Eur Heart J ; 44(46): 4847-4858, 2023 Dec 07.
Article in English | MEDLINE | ID: mdl-37832512

ABSTRACT

BACKGROUND AND AIMS: Intra-pocket ultrasound-guided axillary vein puncture (IPUS-AVP) for venous access in implantation of transvenous cardiac implantable electronic devices (CIED) is uncommon due to the lack of clinical evidence supporting this technique. This study investigated the efficacy and early complications of IPUS-AVP compared to the standard method using cephalic vein cutdown (CVC) for CIED implantation. METHODS: ACCESS was an investigator-led, interventional, randomized (1:1 ratio), monocentric, controlled superiority trial. A total of 200 patients undergoing CIED implantation were randomized to IPUS-AVP (n = 101) or CVC (n = 99) as a first assigned route. The primary endpoint was the success rate of insertion of all leads using the first assigned venous access technique. The secondary endpoints were time to venous access, total procedure duration, fluoroscopy time, X-ray exposure, and complications. Complications were monitored during a follow-up period of three months after procedure. RESULTS: IPUS-AVP was significantly superior to CVC for the primary endpoint with 100 (99.0%) vs. 86 (86.9%) procedural successes (P = .001). Cephalic vein cutdown followed by subclavian vein puncture was successful in a total of 95 (96.0%) patients, P = .21 vs. IPUS-AVP. All secondary endpoints were also significantly improved in the IPUS-AVP group with reduction in time to venous access [3.4 vs. 10.6 min, geometric mean ratio (GMR) 0.32 (95% confidence interval, CI, 0.28-0.36), P < .001], total procedure duration [33.8 vs. 46.9 min, GMR 0.72 (95% CI 0.67-0.78), P < .001], fluoroscopy time [2.4 vs. 3.3 min, GMR 0.74 (95% CI 0.63-0.86), P < .001], and X-ray exposure [1083 vs. 1423 mGy.cm², GMR 0.76 (95% CI 0.62-0.93), P = .009]. There was no significant difference in complication rates between groups (P = .68). CONCLUSIONS: IPUS-AVP is superior to CVC in terms of success rate, time to venous access, procedure duration, and radiation exposure. Complication rates were similar between the two groups. Intra-pocket ultrasound-guided axillary vein puncture should be a recommended venous access technique for CIED implantation.


Subject(s)
Pacemaker, Artificial , Venous Cutdown , Humans , Venous Cutdown/methods , Axillary Vein/surgery , Axillary Vein/diagnostic imaging , Punctures , Ultrasonography, Interventional/methods
4.
Chest ; 127(3): 1053-8, 2005 Mar.
Article in English | MEDLINE | ID: mdl-15764794

ABSTRACT

OBJECTIVE: Continuous positive airway pressure (CPAP) by face mask is an effective method of treating severe cardiogenic pulmonary edema (CPE). However, to our knowledge, no study has provided a precise evaluation of the effects of CPAP on cardiac function in patients presenting with CPE and preserved left ventricular (LV) function. DESIGN: Prospective observational clinical study. SETTING: A 14-bed, medical ICU at a university hospital. PATIENTS: Nine consecutive patients presenting with hypoxemic acute CPE. INTERVENTIONS: All patients were selected for 30 min of CPAP with 10 cm H(2)O by mask with fraction of inspired oxygen adjusted for a cutaneous saturation > 90%. Doppler echocardiography was performed before CPAP application and during the last 10 min of breathing with CPAP. Two-tailed, paired t-tests were used to compare data recorded at baseline (oxygen alone) and after CPAP. MEASUREMENTS AND RESULTS: Four patients presented CPE with preserved left ventricular (LV) function (a preserved LV ejection fraction [LVEF] > 45%, and/or aortic velocity time integral > 17 cm in the absence of aortic stenosis or hypertrophic cardiomyopathy). Oxygenation and ventilatory parameters were improved by CPAP in all patients. Hemodynamic monitoring and Doppler echocardiographic analysis demonstrated that in patients with preserved LV systolic function, mean arterial pressure and LV end-diastolic volume were decreased significantly by CPAP (p < 0.04). In patients with LV systolic dysfunction, CPAP improved LVEF (p < 0.05) and decreased LV end-diastolic volume (p = 0.001) significantly. CONCLUSION: CPAP improves oxygenation and ventilatory parameters in all kinds of CPE. In patients with preserved LV contractility, the hemodynamic benefit of CPAP results from a decrease in LV end-diastolic volume (preload).


Subject(s)
Continuous Positive Airway Pressure , Pulmonary Edema/therapy , Ventricular Dysfunction, Left/complications , Acute Disease , Adult , Aged , Aged, 80 and over , Blood Pressure , Continuous Positive Airway Pressure/methods , Echocardiography, Doppler , Female , Humans , Male , Masks , Middle Aged , Oxygen/blood , Pulmonary Edema/etiology , Pulmonary Edema/physiopathology , Pulmonary Ventilation , Ventricular Dysfunction, Left/diagnostic imaging
5.
Rev Prat ; 52(12): 1301-6, 2002 Jun 15.
Article in French | MEDLINE | ID: mdl-12187892

ABSTRACT

Atrial fibrillation occurs because of a complex interaction between an arrhythmogenic substrate, triggers factors and the autonomic nervous system. Underlying fundamental mechanisms are multiple, can cohabit and include schematically: multiple wavelet, stable microreentry, macro single meandering spiral wave reentry and focal atrial fibrillation arising from the pulmonary veins. More over, new concepts have emerged like the atrial fibrillation-induced electrical and structural remodeling which favors its own perpetuation. Experimental studies have shown a complex interaction between anatomical particularities of the atria and the activation fronts dynamic. All this recent progress open new and more efficient therapeutic perspectives for patients enduring atrial fibrillation.


Subject(s)
Atrial Fibrillation/physiopathology , Atrial Fibrillation/therapy , Autonomic Nervous System/physiology , Defibrillators, Implantable , Heart Atria/pathology , Humans
SELECTION OF CITATIONS
SEARCH DETAIL
...