Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 10 de 10
Filter
1.
Front Cardiovasc Med ; 10: 1106420, 2023.
Article in English | MEDLINE | ID: mdl-36865887

ABSTRACT

Surgical ligation and transcatheter occlusion are the mainstream for the treatment of coronary artery fistulas (CAFs). However, these techniques applied to tortuous and aneurysmal CAF, especially those draining into left-heart, have their known drawbacks. We report, a successful percoronary device closure of such CAF, originating from left main coronary artery and draining into left atrium, through a left subaxillary minithoracotomy. Through a puncture on the distal straight course, we occluded CAF exclusively under transesophageal echocardiography guidance. Complete occlusion was achieved. It's a simple, safe, and effective alternative for tortuous, large, and aneurysmal CAFs draining into the left heart.

2.
Cancer Med ; 12(7): 7992-8004, 2023 04.
Article in English | MEDLINE | ID: mdl-36607128

ABSTRACT

OBJECTIVES: This study aims to use the three-dimensional (3D) mixed-reality model of liver, entailing complex intrahepatic systems and to deeply study the anatomical structures and to promote the training, diagnosis and treatment of liver diseases. METHODS: Vascular perfusion human specimens were used for thin-layer frozen milling to obtain liver cross-sections. The 104-megapixel-high-definition cross sectional data set was established and registered to achieve structure identification and manual segmentation. The digital model was reconstructed and data was used to print a 3D hepatic model. The model was combined with HoloLens mixed reality technology to reflect the complex relationships of intrahepatic systems. We simulated 3D patient specific anatomy for identification and preoperative planning, conducted a questionnaire survey, and evaluated the results. RESULTS: The 3D digital model and 1:1 transparent and colored model of liver established truly reflected intrahepatic vessels and their complex relationships. The reconstructed model imported into HoloLens could be accurately matched with the 3D model. Only 7.7% participants could identify accessory hepatic veins. The depth and spatial-relationship of intrahepatic structures were better understandable for 92%. The 100%, 84.6%, 69% and 84% believed the 3D models were useful in planning, safer surgical paths, reducing intraoperative complications and training of young surgeons respectively. CONCLUSIONS: A detailed 3D model can be reconstructed using the higher quality cross-sectional anatomical data set. When combined with 3D printing and HoloLens technology, a novel hybrid-reality navigation-training system for liver surgery is created. Mixed Reality training is a worthy alternative to provide 3D information to clinicians and its possible application in surgery. This conclusion was obtained based on a questionnaire and evaluation. Surgeons with extensive experience in surgical operations perceived in the questionnaire that this technology might be useful in liver surgery, would help in precise preoperative planning, accurate intraoperative identification, and reduction of hepatic injury.


Subject(s)
Augmented Reality , Humans , Hepatectomy/methods , Imaging, Three-Dimensional/methods , Liver/surgery , Anatomy, Cross-Sectional
3.
Ann Thorac Surg ; 115(3): e71-e73, 2023 03.
Article in English | MEDLINE | ID: mdl-35367437

ABSTRACT

The cardiac hemangioma is a relatively rare cardiac tumor. It can occur in different locations in the heart. We describe a patient with a giant cardiac hemangioma encroaching on the right coronary artery who underwent a successful surgical resection. Complete resection of the tumor was achieved without damaging the function of the right coronary artery. Nonetheless, meticulous follow-up is required as recurrence is possible.


Subject(s)
Heart Neoplasms , Hemangioma , Respiratory Tract Neoplasms , Humans , Coronary Vessels/pathology , Hemangioma/surgery , Heart Neoplasms/surgery
4.
Medicine (Baltimore) ; 100(34): e26943, 2021 Aug 27.
Article in English | MEDLINE | ID: mdl-34449459

ABSTRACT

ABSTRACT: Thyroid nodules are one of the most common entities that affect the thyroid gland. Traditionally, their treatment was surgery. Currently, ablation combination with percutaneous procedure became a good option.To analyze safety, efficacy, and describe our experience in microwave-ablation using ultrasound-guidance for benign thyroid nodules.A total of 304 patients with 1180 thyroid nodules (thyroid cystadenoma and nodular goiter) were studied retrospectively. Two hundred sixty-seven patients who underwent microwave-ablation successfully in our hospital were enrolled in this study. The baseline, follow-up nodule volume, thyroid function tests, thyroid antibodies, and posttherapy complications were analyzed. The informed written consent was obtained from patients or guardians. The study was approved by the ethics committee of our hospital.The average age was 50.1 ±â€Š11.7 (21-83 years), 214 were women (80.1%) and 53 (19.9%) were men. The average number of nodules per patient was 4.02 ±â€Š1.8 (1-8), 9.86%, 6.13%, and 84% located in the right thyroid lobe, left lobe, and bilateral, respectively. The average size of the nodules was 5.28 cm2 ±â€Š3.63 (0.09-23.45 cm2). The average ablation time was 11 minutes ±â€Š5.36 (3-20 minutes). The hospitalization period was 24 hours ±â€Š10.16 (7-48 hours). Eighteen complications were reported. Postablation volume reduction rate was 54.74% and 93.3% at 3 and 12 months follow-up respectively (P < .05). The thyroid function tests, pre and postablation showed no significant changes (P > .05).Ultrasound-guided microwave-ablation of thyroid nodules is safe and effective. More clinical trials are needed to define the true use of microwave-ablation.


Subject(s)
Cystadenoma/surgery , Goiter, Nodular/surgery , Radiofrequency Ablation/methods , Adult , Aged , Aged, 80 and over , Female , Humans , Male , Microwaves , Middle Aged , Radiofrequency Ablation/adverse effects , Retrospective Studies , Thyroid Function Tests , Thyroid Gland/surgery , Ultrasonography, Interventional , Young Adult
5.
Int. braz. j. urol ; 47(1): 93-99, Jan.-Feb. 2021. tab, graf
Article in English | LILACS | ID: biblio-1134320

ABSTRACT

ABSTRACT Hypothesis: Endoclip can be used as fiducial marker in urology. Objective: To assess the feasibility, cost effectiveness and reliability of endoclips as novel fiducial markers in precision radiotherapy, as part of a trimodality bladder-preserving treatment (TBPT) of muscle-invasive bladder carcinoma. Materials and Methods: This retrospective study was performed at Weifang People's Hospital (Weifang, China) from January 2015 to June 2018. A total of 15 patients underwent TBPT. Endoclips were applied to healthy edges of the resected bladder wall as novel fiducial markers. Radio-sensitizing chemotherapy and routine precision radiotherapy were given. The number and position of the endoclips during radiotherapy sessions were monitored. Complications and tumor recurrence were analyzed. Results: The mean age (±standard deviation) of the patients was 67±10 years (range 46-79). There were 3 females and 12 males. Forty-nine endoclips were applied in all patients (3.3±0.8). The tumor was completely visibly resected in all patients. The number of endoclips remained the same through the planned last radiotherapy session (3.3±0.8), i.e., none were lost. All endoclips were removed after the last radiotherapy session. The average number of follow-up months was 38.9±13.2 (range 11-52). There were no procedure-related complications at discharge or follow-up. At one-year, overall recurrence-free survival was 93.3%. Two patients had recurrences at 18 months and 10 months after TBPT, respectively, and salvage radical cystectomy was performed with no further recurrences. Another patient died due to metastasis 9 months after the completion of therapy. Conclusions: Endoclips are reliable, safe and cost-effective as novel fiducial markers in precision-radiotherapy post-TBPT.


Subject(s)
Humans , Male , Female , Aged , Urinary Bladder Neoplasms/surgery , Urinary Bladder Neoplasms/radiotherapy , Carcinoma , Urinary Bladder , Cystectomy , China , Feasibility Studies , Reproducibility of Results , Retrospective Studies , Treatment Outcome , Combined Modality Therapy , Fiducial Markers , Middle Aged , Muscles , Neoplasm Invasiveness , Neoplasm Recurrence, Local
6.
Int Braz J Urol ; 47(1): 93-99, 2021.
Article in English | MEDLINE | ID: mdl-32271508

ABSTRACT

HYPOTHESIS: Endoclip can be used as fiducial marker in urology. OBJECTIVE: To assess the feasibility, cost effectiveness and reliability of endoclips as novel fiducial markers in precision radiotherapy, as part of a trimodality bladder-preserving treatment (TBPT) of muscle-invasive bladder carcinoma. MATERIALS AND METHODS: This retrospective study was performed at Weifang People's Hospital (Weifang, China) from January 2015 to June 2018. A total of 15 patients underwent TBPT. Endoclips were applied to healthy edges of the resected bladder wall as novel fiducial markers. Radio-sensitizing chemotherapy and routine precision radiotherapy were given. The number and position of the endoclips during radiotherapy sessions were monitored. Complications and tumor recurrence were analyzed. RESULTS: The mean age (±standard deviation) of the patients was 67±10 years (range 46-79). There were 3 females and 12 males. Forty-nine endoclips were applied in all patients (3.3±0.8). The tumor was completely visibly resected in all patients. The number of endoclips remained the same through the planned last radiotherapy session (3.3±0.8), i.e., none were lost. All endoclips were removed after the last radiotherapy session. The average number of follow-up months was 38.9±13.2 (range 11-52). There were no procedure-related complications at discharge or follow-up. At one-year, overall recurrence-free survival was 93.3%. Two patients had recurrences at 18 months and 10 months after TBPT, respectively, and salvage radical cystectomy was performed with no further recurrences. Another patient died due to metastasis 9 months after the completion of therapy. CONCLUSIONS: Endoclips are reliable, safe and cost-effective as novel fiducial markers in precision-radiotherapy post-TBPT.


Subject(s)
Carcinoma , Urinary Bladder Neoplasms , Aged , China , Combined Modality Therapy , Cystectomy , Feasibility Studies , Female , Fiducial Markers , Humans , Male , Middle Aged , Muscles , Neoplasm Invasiveness , Neoplasm Recurrence, Local , Reproducibility of Results , Retrospective Studies , Treatment Outcome , Urinary Bladder , Urinary Bladder Neoplasms/radiotherapy , Urinary Bladder Neoplasms/surgery
7.
Br J Neurosurg ; 34(2): 154-160, 2020 Apr.
Article in English | MEDLINE | ID: mdl-31975630

ABSTRACT

Objective: Mixed growth hormone (GH) and prolactin (PRL) secreting adenomas are the most common type of plurihormonal pituitary adenomas. We assessed the clinical presentations and impacts of transsphenoidal surgery (TS) on patients with mixed GH and PRL adenomas including surgical outcomes, complications, and prognosis.Method and patients: Twelve patients (7 males, 5 females) were operated in the neurosurgery department of Qilu hospital affiliated to Shandong University, Shandong, China. We analyzed hormone levels of preoperation, postoperation (within 24 h) and at 12-month follow-up and correlated levels with tumor volumes.Results: The remission rate was 66.7% (8/12), the recurrence rate was 16.7% (2/12), the cause-specific mortality was 0 and the overall mortality rate was 16.7% (2/12) due to stroke and myocardial infarction respectively. A significant drop was seen in GH, PRL, and Insulin-like-growth-factor-1 (IGF-1) levels between preoperation and postoperation with mean values from 52.6 to 9.9 ng/ml (p = 0.0015), from 321.6 to 190.9 ng/ml (p = 0.0026) and from 815.7 to 230.6 ng/ml (p = 0.0004), respectively. This drop was more significant between preoperation and follow-up with mean values from 52.6 to 3.0 ng/ml (p = 0.002), from 321.6 to 61.6 ng/ml (p < 0.0001), and from 815.7 to 195.0 ng/ml (p = 0.0001), respectively. However, there was no significant correlation between tumor volume and all of the hormone levels.Conclusions: Most mixed GH and PRL adenomas are aggressive with a high risk of recurrence and mortality.


Subject(s)
Pituitary Neoplasms , Prolactinoma , China , Female , Growth Hormone , Humans , Male , Neoplasm Recurrence, Local/surgery , Pituitary Neoplasms/surgery , Prolactinoma/surgery
8.
J Cardiothorac Surg ; 14(1): 130, 2019 Jul 04.
Article in English | MEDLINE | ID: mdl-31272459

ABSTRACT

BACKGROUND: There are no unanimous reports on different layouts and classifications of multi-hole secundum atrial septal defects (MHASD) and subsequent standardized occlusion techniques. The MHASD can be isolated or cribriform with variable inter-defects distance. In this retrospective study, experience-based classification and two approaches-based occlusion results are presented. METHODS: We retrospectively collected and analyzed data of 150 MHASD patients from 1320 patients who underwent atrial septal defect occlusion in our institute. The MHASD patients were categorized into 4 types; type A, B, C and D and occluded under exclusive transesophageal echocardiographic guidance. According to different types, 122 patients were occluded using peratrial approach and 28 patients via percutaneous approach. In type A, single device implantation is performed to occlude the large hole and squeeze the small one. For type B single or double-device deployment was performed depending on an inter-defects distance. In type C and D, a patent foramen-ovale (PF) device was selectively positioned to the central defect to occlude the central defect and cover the peripheral ones. In peratrial approach, 8 patients underwent inter-defects septal puncture technique to achieve single-device occlusion. The intracardiac manipulation time, procedural time, double device deployment, redeployment rate, residual shunt, and proportions were analyzed between (and within peratrial technique) two techniques. RESULTS: Successful occlusion was achieved in all 150 patients. Single device occlusion was applied in 78/84 type A and 22/37 type B patients (p < 0.05). Double device occlusion was more applicable to type B than A patients (p < 0.01). Sixteen of 21 type C and all type D patients used PF device for a satisfactory occlusion. Redeployment of the device occurred frequently in type B patients than A (p < 0.01). The intracardiac manipulation time and procedural time were shorter in type A than B (p < 0.05). The intracardiac manipulation time was also shortened in type A peratrial than type A percutaneous group (p < 0.05). Complete occlusion rate for all patients at discharge was 70% and rose to 82% at 1 year follow up. CONCLUSIONS: The diverse layouts and classification of MHASDs can help to choose different techniques and proper devices of different kinds to achieve better occlusion results.


Subject(s)
Cardiac Surgical Procedures/methods , Heart Septal Defects, Atrial/classification , Heart Septal Defects, Atrial/surgery , Septal Occluder Device , Adult , Aged , Cardiac Surgical Procedures/instrumentation , Echocardiography, Transesophageal , Female , Follow-Up Studies , Heart Septal Defects, Atrial/diagnostic imaging , Humans , Male , Middle Aged , Retrospective Studies , Treatment Outcome
9.
Ann Thorac Surg ; 105(6): 1710-1716, 2018 06.
Article in English | MEDLINE | ID: mdl-29408247

ABSTRACT

BACKGROUND: The current approaches of transcatheter closure of mitral paravalvular leak (MPVL) have different drawbacks. The challenges come from transseptal puncture, accessing the MPVL site, and the absence of dedicated delivery systems. This study introduces a novel peratrial approach for device closure of different locations of MPVLs using a probe-assisted delivery system under three-dimensional transesophageal echocardiography. METHODS: A 4.0-cm minithoracotomy incision was made in the fourth right interspaces. The right atrium and the interatrial septum were punctured and dilated, followed by a guidewire passing through the septum. A specially designed J-shaped bendable hollow probe was advanced into the left atrium. The steerable probe was adjusted to cross the MPVL and introduced a stiff guidewire into the left ventricle. A 7F short delivery sheath was advanced over the wire through the MPVL into the left ventricle. A proper-sized muscular septal occluder was then selected and deployed. RESULTS: Transesophageal echocardiography revealed complete occlusion in 7 of 8 patients after a follow-up of 6 months to 4 years. Mild residual paravalvular regurgitation occurred in an early patient. In 2 patients with a crescent-shaped MPVL, two guidewires were advanced into the left ventricle across the leak, and double devices were deployed sequentially. All patients' symptoms improved by at least one New York Heart Association functional class. CONCLUSIONS: The peratrial technique can access and close MPVLs at different locations through a right minithoracotomy approach. This technique has the advantages of easy transseptal puncture, easy access to the MPVL site, and no exposure to radiation.


Subject(s)
Anastomotic Leak/surgery , Echocardiography, Transesophageal , Heart Valve Prosthesis Implantation/adverse effects , Mitral Valve Insufficiency/surgery , Septal Occluder Device , Adult , Aged , Anastomotic Leak/diagnostic imaging , Cohort Studies , Female , Heart Valve Prosthesis Implantation/methods , Humans , Male , Middle Aged , Minimally Invasive Surgical Procedures/methods , Mitral Valve Insufficiency/diagnostic imaging , Prognosis , Prosthesis Failure , Reoperation/methods , Retrospective Studies , Risk Assessment , Thoracotomy/methods , Treatment Outcome , Young Adult
10.
J Cardiothorac Surg ; 12(1): 24, 2017 Apr 17.
Article in English | MEDLINE | ID: mdl-28412961

ABSTRACT

BACKGROUND: Device closure of a wide-spaced multi-hole PmVSD is difficult to succeed in percutaneous approach. This study is to evaluate the feasibility, safety and efficacy of perventricular device closure of wide-spaced multi-hole PmVSD using a double-device implanting technique. METHODS: Sixteen patients with wide-spaced multi-hole PmVSD underwent perventricular closure with two devices through an inferior median sternotomy approach under transesophageal echocardiographic guidance. The largest hole and its adjacent small holes were occluded with an optimal-sized device. The far-away residual hole was occluded with the other device using a probe-assisted delivery system. All patients were followed up for a period of 1 to 4 years to determine the residual shunt, atrioventricular block and the adjacent valvular function. RESULTS: The number of the holes of the PmVSD was 2 to 4. The maximum distance between the holes was 5.0 to 10.0 mm (median, 6.4 mm). The diameter of the largest hole was 2.5 to 7.0 mm (median, 3.6 mm). The success rate of double-device closure was 100%. Immediate residual shunts were found in 6 patients (38%), and incomplete right bundle branch block at discharge occurred in 3 cases (19%). Both complications decreased to 6% at 1-year follow-up. Neither of them had a severe device-related complication. CONCLUSIONS: Perventricular closure of a wide-spaced multi-hole PmVSD using a double-device implanting technique is feasible, safe, and efficacious. In multi-hole PmVSDs with the distance between the holes of more than 5 mm, double-device implantation may achieve a complete occlusion.


Subject(s)
Cardiac Catheterization/methods , Cardiac Surgical Procedures/instrumentation , Heart Septal Defects, Ventricular/surgery , Septal Occluder Device , Adolescent , Adult , Child , Child, Preschool , Echocardiography , Equipment Design , Female , Follow-Up Studies , Heart Septal Defects, Ventricular/diagnosis , Humans , Infant , Male , Radiography, Thoracic , Retrospective Studies , Treatment Outcome , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL
...