Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 20 de 41
Filter
Add more filters










Publication year range
1.
J Pharm Biomed Anal ; 248: 116275, 2024 Sep 15.
Article in English | MEDLINE | ID: mdl-38959760

ABSTRACT

In this study we report on efforts to develop an enantioselective method for the detection of the drug of abuse clephedrone (1-(4-chlorophenyl)-2-(methylamino)-1-propanone (4-chloromethcathinone, also known as 4-CMC or para-chloro-methcathinone)) and its phase-1 metabolites in human biological fluids. The major goal is not to only report results, but primarily to emphasize the various challenges encountered when developing a reliable analytical method for the detection and quantification of novel psychoactive substances (NPS) and their metabolites in the matrix of interest. Such challenges start with the lack of chemical stability of some NPS in biological matrices. Additionally, most often metabolites are unavailable in pure form to serve as analytical standards, just as deuterated standards for native drugs and metabolites are frequently not commercially available. Furthermore, if the NPS is chiral, enantiomerically pure standards with known absolute stereochemistry are required, as well as a stereochemical stability of a drug and its metabolites becomes an issue. In addition, the chirality of a NPS significantly increases the number of species to be detected in the sample and thus challenges the development of an adequate separation method. These issues are shortly addressed, and some solutions offered in this manuscript.


Subject(s)
Psychotropic Drugs , Stereoisomerism , Psychotropic Drugs/analysis , Psychotropic Drugs/chemistry , Humans , Propiophenones/chemistry , Propiophenones/analysis , Illicit Drugs/analysis , Illicit Drugs/chemistry , Substance Abuse Detection/methods
2.
J Pharm Biomed Anal ; 249: 116350, 2024 Jul 10.
Article in English | MEDLINE | ID: mdl-39047462

ABSTRACT

The stereochemical stability of the popular drugs of abuse 2-, 3- and 4-chloromethcathinone was studied in the mobile phase used for the isolation of their enantiomers by high-performance liquid chromatography, as well as in various biological matrixes such as whole blood, saliva and urine. For 2-, 3-, and 4-chloromethcathinones the rate constants and half-lives of their first order racemization reaction was assessed. It was found that at 25 °C the racemization rate constant decreases in the order 2-CMC > 3-CMC > 4-CMC while their stereochemical stability in biological matrixes decreases in the order urine > saliva > whole blood. This information must be considered for the adequate storage of purified enantiomers in the collected fractions, as well as in the studies focused on their enantioselective transformation in the human body.

3.
J Chromatogr A ; 1730: 465062, 2024 Aug 16.
Article in English | MEDLINE | ID: mdl-38889581

ABSTRACT

Hydrogen/deuterium (H/D) isotope effects are not unusual in chromatography and such phenomena have been observed in both gas- and liquid-phase separations. Despite the numerous reports on this topic, the understanding of mechanisms and the underlying noncovalent interactions at play remains rather challenging. In our recent study, we reported baseline separation of isotopologoues of some amphetamine (AMP) derivatives on achiral and polysaccharide-based chiral columns, as well as some correlations between the degree of separation of enantiomers and isotopologues on (the same) polysaccharide-based chiral column(s). Following our previous findings on isotope effects in high-performance liquid chromatography, we report herein a comparative study on the isotope effects observed with AMP and methamphetamine (MET). The impact of some pivotal factors such as the number of deuterium atoms part of AMP isotopologues, the structure of its isotopomers, the chemical structure of the achiral and chiral stationary phases used in this study, and the use of methanol- vs acetonitrile-containing mobile phases on the isotope effects was examined and discussed. Quantitative correlations between the observed isotope effects and the enantioselectivity of the chiral columns used are also shortly discussed. Furthermore, considering the chromatographic results as benchmark experimental data, we attempted to elucidate the molecular bases of the observed phenomena using quantum mechanics calculations.


Subject(s)
Amphetamine , Deuterium , Polysaccharides , Chromatography, High Pressure Liquid/methods , Stereoisomerism , Deuterium/chemistry , Amphetamine/chemistry , Amphetamine/isolation & purification , Polysaccharides/chemistry , Polysaccharides/isolation & purification , Methamphetamine/chemistry , Methamphetamine/isolation & purification , Acetonitriles/chemistry , Methanol/chemistry
4.
J Pharm Biomed Anal ; 248: 116293, 2024 Sep 15.
Article in English | MEDLINE | ID: mdl-38901154

ABSTRACT

A method of analysis was developed for the simultaneous chemo- and enantioseparation of 2-, 3-, and 4-chloromethcathinones by high-performance liquid chromatography tandem mass-spectrometry. The fast method enables the reliable identification of positional isomers of chloromethcathinones in biological samples. In addition, the same method can be used for the enantioselective quantitative determination of one of these compounds and its major phase-1 metabolites in biological fluids. The developed method was applied to oral fluid samples collected by police during routine random traffic control in Belgium from January to November, 2023. It was found that 3-CMC was more frequently abused compared to 4-CMC. Although some differences were observed between the concentrations of enantiomers in OF, most likely the drugs were abused in the racemic form. No abuse of 2-CMC was detected at the timepoint of sample collection.


Subject(s)
Saliva , Tandem Mass Spectrometry , Tandem Mass Spectrometry/methods , Chromatography, High Pressure Liquid/methods , Humans , Saliva/chemistry , Stereoisomerism , Propiophenones/chemistry , Propiophenones/analysis , Substance Abuse Detection/methods , Belgium
5.
J Pharm Biomed Anal ; 243: 116076, 2024 Jun 15.
Article in English | MEDLINE | ID: mdl-38430614

ABSTRACT

Recently we published in this journal an enantioselective high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method for the quantitative determination of 3,4-methylenedioxymethamphetamine (MDMA) and its major phase-1 metabolites, 4-hydroxy-3-methoxyamphetamine (HMA), 4-hydroxy-3-methoxymethamphetamine (HMMA) and 3,4-methylenedioxyamphetamine (MDA) in human plasma, sweat, oral fluid and urine. Since we did not achieve simultaneous enantioseparation of all 4 compounds with a single chiral column, two amylose-based chiral columns were used alternatively. Further optimization of the mobile phase in the present study enabled baseline separation of all four pairs of enantiomers on a single Lux AMP column. In addition, by optimization of the column dimension and applied flow-rate it became possible to complete the separation within 6 minutes. These new methods were applied to the analysis of human plasma, oral fluid and urine. While results on the concentration of MDMA and its metabolites in various biological fluids were reported in our recent publication, in the present study an attempt was made to hydrolyze glucuronides in urine samples by using alternatively, hydrochloric acid or glucuronidase and to evaluate the effect of hydrolysis on the concentration and enantiomeric distribution of hydroxy metabolites of MDMA such as HMA and HMMA.


Subject(s)
3,4-Methylenedioxyamphetamine , Lactates , Methamphetamine , N-Methyl-3,4-methylenedioxyamphetamine , Humans , N-Methyl-3,4-methylenedioxyamphetamine/urine , Chromatography, High Pressure Liquid , Tandem Mass Spectrometry , Chromatography, Liquid , Stereoisomerism , 3,4-Methylenedioxyamphetamine/urine
6.
J Chromatogr A ; 1718: 464684, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38350350

ABSTRACT

Adeno-associated virus (AAV) analytical characterization is crucial to the well-defined and reproducible production of human gene therapies utilizing the AAV vector modality. The establishment of analytical methods based upon technology platforms currently widely used by bio-therapeutic manufacturers, namely HPLC, will assist efforts to produce high quality AAV reproducibly and decrease chemical manufacturing and control challenges in method portability and reliability. AAV analysis by size exclusion chromatography (SEC) is currently practiced with columns and mobile phase conditions traditional to SEC of proteins. Here, an improved method to measure multiple AVV critical quality attributes (CQA) rapidly by SEC is explored. The use of short columns made with small particles at high flow rates resulted in up to 80 % reduction in analysis time and 66 % in sample consumption while maintaining reliable quantitation of AAV aggregate or high molecular weight (HMW) content. These results were demonstrated across four different AAV serotypes. Furthermore, critical AAV sample handling learnings are shared.


Subject(s)
Dependovirus , Proteins , Humans , Dependovirus/genetics , Dependovirus/metabolism , Reproducibility of Results , Proteins/metabolism , Chromatography, Gel , Chromatography, High Pressure Liquid , Genetic Vectors
7.
J Chromatogr A ; 1718: 464709, 2024 Mar 15.
Article in English | MEDLINE | ID: mdl-38350352

ABSTRACT

The different behavior of enantiomers of chiral compounds in non-isotropic environments (among them in living organism) is well known. On the other hand, the importance of a kinetic isotope effect in the biomedical field has become evident during past few decades. Thus, separation of both, enantiomers and isotopologues is now critical. Only very few published studies have attempted the simultaneous separation of enantioisotopologues. In this article we report baseline separation of partially deuterated isotopologues of a few amphetamine derivatives in high-performance liquid chromatography (HPLC) using achiral columns. In addition, the simultaneous separations of enantiomers and isotopologues (i.e. enantioisotopologues) were attempted on polysaccharide-based chiral columns. For several compounds the isotope effect was tunable and could be switched from a "normal" to "inverse" by making changes to the mobile-phase composition. A stronger isotope effect was observed in acetonitrile-containing mobile phases compared to methanol-containing ones with both chiral and achiral columns. In a separation system where both "normal" and "inverse" isotope effects were observed the "normal" isotope effect was favored in polar organic solvents while increasing content of the aqueous component in the reversed-phase (RP) mobile phase favored an "inverse" isotope effect. This observation indicates that polar, hydrogen bonding-type noncovalent interactions are involved in the "normal" isotope effect, while apolar hydrophobic-type interactions are mostly responsible for the "inverse" isotope effect.


Subject(s)
Amphetamine , Polysaccharides , Chromatography, High Pressure Liquid/methods , Polysaccharides/chemistry , Solvents/chemistry , Isotopes , Stereoisomerism
8.
Article in English | MEDLINE | ID: mdl-37487291

ABSTRACT

In the present study an enantioselective high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the first time for quantitative determination of the recreational drug of abuse methylone and its major metabolites in oral fluid. The simultaneous chemo- and enantioseparation of methylone and its major metabolites was performed on a polysaccharide-based chiral column based on amylose tris(5-chloro-3-methylphenylcarbamate) as chiral selector (Lux i-Amylose-3) with methanol containing 0.4 % (v/v) aqueous ammonium hydroxide as mobile phase. The time required for enantioselective analysis of methylone and its 2 major metabolites was 15 min. This method was fully validated following the Organization of Scientific Area Committees (OSAC) for Forensic Science guidelines. This method was applied for the enantioselective determination of methylone and its metabolites in oral fluid and enantioselectivity in metabolism and pharmacokinetic of the parent compound and metabolites was observed. While the first enantiomer of methylone was found at higher concentration, both metabolites shown greater concentration for the second enantiomer. The results revealed that MET undergoes an enantioselective biotransformation to its metabolites HMMC and MDC, with S-(-)-MET more rapidly metabolized and eliminated from the body.


Subject(s)
Amylose , Tandem Mass Spectrometry , Chromatography, High Pressure Liquid/methods , Chromatography, Liquid/methods , Tandem Mass Spectrometry/methods , Amylose/chemistry , Stereoisomerism
9.
J Pharm Biomed Anal ; 230: 115384, 2023 Jun 15.
Article in English | MEDLINE | ID: mdl-37044005

ABSTRACT

In the present work an isocratic enantioselective high-performance liquid chromatography-tandem mass spectrometry (LC-MS/MS) method was developed for the separation and quantitative determination of dextro - and levo -methorphan and their pharmacologically relevant metabolites, dextrorphan and levorphanol, respectively, in human blood samples. The separation of enantiomers of methorphan and metabolites was performed on the polysaccharide-based chiral column Lux AMP in combination with acetonitrile and 5 mM aqueous ammonium bicarbonate pH 11 in the ratio 50:50 (%, v/v) as mobile phase with the flow rate 1 mL/min. The mass spectrometer was operated in scheduled multiple reaction monitoring (MRM) mode, with four transitions for each dextromethorpan, levomethorphan, dextrorphan and dextromethorphan-d3 and two transitions for each levorphanol, levorphanol-d3 and dextrorphan-d3. Application of this method to human post-mortem blood samples confirmed cases of severe overdosing with dextromethorphan, levomethorphan, and less commonly with both.


Subject(s)
Dextromethorphan , Dextrorphan , Humans , Dextromethorphan/chemistry , Chromatography, High Pressure Liquid/methods , Chromatography, Liquid , Tandem Mass Spectrometry/methods , Stereoisomerism , Levorphanol
10.
J Chromatogr A ; 1630: 461532, 2020 Sep 12.
Article in English | MEDLINE | ID: mdl-32950816

ABSTRACT

An unusual convex-upward van Deemter curve was observed for the more retained enantiomer of a chiral sulfoxide (2-(benzylsulfinyl)benzamide) on a cellulose tris(4-chloro-3-methylphenylcarbamate)-based chiral stationary phase (CSP), prepared on silica particles of 1000 Å pore size. In contrast, the firstly eluted enantiomer of the same molecule exhibited the traditional convex-downward van Deemter curve. A detailed kinetic and thermodynamic investigation has revealed that this unusual phenomenon, which however has already been observed in chiral chromatography, originates when the adsorption of the compound is very strong and the solid-phase diffusion negligible. Experimentally, the intraparticle diffusion of the more retained enantiomer of the sulfoxide was found to be one order of magnitude smaller than that of the first eluted one. Overall, this translates into very little longitudinal diffusion (b-term of van Deemter curve) accompanied by high solid-liquid mass transfer resistance (c-term). Finally the comparison with another, differently-substituted chiral sulfoxide (whose enantiomers both exhibit traditional van Deemter curve behavior) has allowed to correlate these findings to the specific characteristics of the molecule.

11.
J Chromatogr A ; 1625: 461297, 2020 Aug 16.
Article in English | MEDLINE | ID: mdl-32709340

ABSTRACT

In this study superficially porous silica particles with a nominal pore size of 450 Å and average particle size of 2.6 micrometers was compared to fully porous silica particles with nominal particle size 3 micrometers and nominal pore size 1000 A as carriers for a polysaccharide based chiral selector for the separation of enantiomers in high-performance liquid chromatography. In addition, the effects of chiral selector loading onto the silica support and of column internal dimeter in the case of both, superficially porous and totally porous silica, as well as of the pore size of superficially porous silica on column performance were studied. The dependence of plate height on mobile phase flow rate was also studied and attempts were made for shortening analysis time. The baseline separation of enantiomers of some chiral sulfoxides was obtained within 2.0-4.5 s.


Subject(s)
Chromatography, High Pressure Liquid/methods , Polysaccharides/chemistry , Silicon Dioxide/chemistry , Particle Size , Porosity , Stereoisomerism
12.
J Chromatogr A ; 1624: 461218, 2020 Aug 02.
Article in English | MEDLINE | ID: mdl-32540066

ABSTRACT

In this study, amylose- and cellulose-phenylcarbamate-based chiral columns with different chiral-selector (CS) chemistries were compared to each other for the separation of enantiomers of basic chiral analytes in acetonitrile and aqueous-acetonitrile mobile phases in HPLC. For two chemistries the amylose-based columns with coated and immobilized CSs were also compared. The comparison of CSs containing only electron-donating or electron-withdrawing substituents with those containing both electron-donating and electron-withdrawing substituents showed opposite results for the studied set of chiral analytes in the case of amylose and cellulose derivatives. Along with the chemistry of CS the focus was on the behavior of polysaccharide phenylcarbamates in acetonitrile versus aqueous acetonitrile as eluents. In agreement with earlier results, it was found that in contrast to the commonly accepted view, polysaccharide phenylcarbamates do not behave as typical reversed-phase materials for basic analytes either. In the range of water content in the mobile phase of up to 20-30% v/v the behavior of these CSs is similar to hydrophilic interaction liquid chromatography (HILIC)-type adsorbents. This means that with increasing water content in the mobile phase up to 20-30% v/v, the retention of analytes mostly decreases. The important finding of this study is that the separation efficiency improves for most analytes when switching from pure acetonitrile to aqueous acetonitrile. Therefore, in spite of reduced retention, the separation of enantiomers improves and thus, the HILIC-range of mobile phase composition, offering shorter analysis time and better peak resolution, is advantageous over pure polar-organic solvent mode. Interesting examples of enantiomer elution order (EEO) reversal were observed for some analytes based on the content of water in the mobile phase on Lux Cellulose-1 and Lux Amylose-2 columns.


Subject(s)
Amylose/chemistry , Cellulose/chemistry , Chromatography, High Pressure Liquid/methods , Pharmaceutical Preparations/isolation & purification , Phenylcarbamates/chemistry , Acetonitriles/chemistry , Electrons , Ethanolamines/analysis , Ethanolamines/isolation & purification , Pharmaceutical Preparations/analysis , Propanolamines/analysis , Propanolamines/isolation & purification , Propranolol/analysis , Propranolol/isolation & purification , Stereoisomerism , Water/chemistry
13.
J Chromatogr A ; 1609: 460445, 2020 Jan 04.
Article in English | MEDLINE | ID: mdl-31431357

ABSTRACT

The separation of 14 chiral sulfoxides was systematically studied on 12 cellulose-based chiral columns in acetonitrile and acetonitrile-water mobile phases. Out of all monosubstituted methylphenylcarbamates of cellulose the one having a methyl moiety in position 3 showed more universal chiral resolving ability compared to 2- and 4-substituted derivatives. Out of disubstituted phenylcarbamates of cellulose the ones with methyl substituents showed higher enantiomer resolving ability compared to chloro-substituted ones and substitution in positions 3 of the phenyl moiety was clearly advantageous. From disubstituted derivatives those possessing a combination of methyl- and chloro-substituents were advantageous compared to the ones having dimethyl- or dichloro-substituents. Chiral recognition ability of most chiral selectors towards studied sulfoxides was higher in pure acetonitrile compared to previously studied methanol. The effect of water addition to the mobile phase on analyte retention and enantioseparation was also quite different from that observed with methanol. In particular, with aqueous methanol by increasing the water content in the mobile phase retention increased in most cases and the separation factor improved. In contrast, with aqueous acetonitrile retention and separation factors decreased up to a certain water content in the mobile phase and then started to recover again for most of the studied analytes.


Subject(s)
Acetonitriles/chemistry , Cellulose/chemistry , Chromatography, High Pressure Liquid/methods , Sulfoxides/chemistry , Sulfoxides/isolation & purification , Water/chemistry , Methanol/chemistry , Phenylcarbamates/chemistry , Stereoisomerism
14.
J Chromatogr A ; 1602: 228-236, 2019 Sep 27.
Article in English | MEDLINE | ID: mdl-31126590

ABSTRACT

The separation of enantiomers of some chiral weak acids was studied in HPLC with chiral HPLC columns prepared by coating or covalent immobilization of the same chiral selector, namely amylose tris(3-chloro-5-methylphenylcarbamate) onto silica. After screening some representatives of arylpropionic acid derivatives, coumarins and barbiturates in hydrocarbon-alcohol type mobile phases, we studied the temperature dependence of separation parameters for ketoprofen and naproxen. Instances of reversal of the enantiomer elution order were observed function of column temperature, nature of polar modifier and its content in the mobile phase, as well as between the coated and covalently immobilized versions of the columns made with more-or-less the same chiral selector. Thermodynamic parameters such as Gibb's free energy, the standard molar entropy and the standard molar enthalpy of analyte transfer from the mobile to the stationary phase were calculated in some cases in order to explain the differences observed in the enantiomer separation ability and pattern of coated and covalently immobilized columns.


Subject(s)
Acids/isolation & purification , Carbamates/chemistry , Chemistry Techniques, Analytical/methods , Chromatography, High Pressure Liquid , Silicon Dioxide/chemistry , Entropy , Stereoisomerism , Temperature , Thermodynamics
15.
J Chromatogr A ; 1599: 172-179, 2019 Aug 16.
Article in English | MEDLINE | ID: mdl-31005292

ABSTRACT

This article describes our attempt to re-visit the role of temperature in the separation of enantiomers with polysaccharide-based chiral columns in high-performance liquid chromatography (HPLC). Rarely observed increased retention and separation factors with increasing temperature, as well as temperature dependent reversal of enantiomer elution order are reported for several arylpropionic acid derivatives. Chiral columns with coated and covalently immobilized chiral selectors were compared from the viewpoint of effect of temperature on analyte retention, enantiomer separation and enantiomer elution order. Thermodynamic parameters were calculated for analyte transfer from the liquid phase to the chiral stationary phase and the effect of temperature on chiral selectors was investigated by using differential scanning calorimetry (DSC). DSC results along with chromatographic studies indicate that polysaccharide-based chiral selectors undergo some kind of transition at elevated temperature that is not reversible in the thermodynamic sense of this term.


Subject(s)
Chromatography, High Pressure Liquid , Polysaccharides/chemistry , Propionates/isolation & purification , Temperature , Propionates/analysis , Stereoisomerism
16.
J Chromatogr A ; 1585: 207-212, 2019 Jan 25.
Article in English | MEDLINE | ID: mdl-30497824

ABSTRACT

In this short communication preliminary results are reported on the separation of enantiomers of underivatized amino acids on polysaccharide-based chiral columns in sub/super-critical fluid chromatography (SFC). Racemic mixtures of 14 amino acids were used to evaluate the chiral recognition ability of 8 different polysaccharide-based chiral columns with coated or covalently immobilized chiral selectors. Among the studied columns, the one based on cellulose (3,5-dichlorophenylcarbamate) exhibited the most universal chiral recognition ability providing baseline resolution for the enantiomers of 10 studied amino acids. In addition, the effect of mobile phase composition (in particular, of the amount of additive used), as well as the potential contribution of evaporative light scattering detector (ELSD) to extra column band-broadening was evaluated.


Subject(s)
Amino Acids/chemistry , Amino Acids/isolation & purification , Chemistry Techniques, Analytical/instrumentation , Chemistry Techniques, Analytical/methods , Chromatography, Supercritical Fluid , Polysaccharides/chemistry , Stereoisomerism
17.
J Chromatogr A ; 1571: 132-139, 2018 Oct 12.
Article in English | MEDLINE | ID: mdl-30098733

ABSTRACT

Our earlier studies have demonstrated the applicability of polysaccharide-based chiral selectors in combination with superficially porous (or core-shell) silica (SPS) particles for the preparation of highly efficient chiral stationary phases (CSP). In earlier studies, CSPs were prepared by coating (adsorption) of the chiral selector onto the surface of silica. In this study we report for the first time the CSP obtained by covalent immobilization of a chiral selector onto the surface of SPS particles. The applicability of this CSP for the separation of enantiomers in pure methanol and acetonitrile, as well as in n-hexane/2-propanol mobile phases is shown. The effect of the injected sample amount, mobile phase flow rate and detection frequency on separation performance were studied, as well as high efficiency separation of enantiomers with the analysis time less than 30 s was attempted.


Subject(s)
Cellulose/chemistry , Chromatography, High Pressure Liquid/methods , Silicon Dioxide/chemistry , Benzamides/chemistry , Polysaccharides/chemistry , Porosity , Stereoisomerism
18.
J Chromatogr A ; 1572: 37-43, 2018 Oct 19.
Article in English | MEDLINE | ID: mdl-30139619

ABSTRACT

In this study our preliminary attempt for obtaining fast and highly efficient separations of enantiomers in high-performance liquid chromatography with slightly modified state-of-the-art commercial instrumentation is described. In order to reach this goal after careful selection of chiral analytes, the preparation of chiral stationary phase (CSP), mobile phase composition and column dimensions were optimized. The concept of segmented chiral-achiral column was introduced. As the result of these optimizations baseline separation of enantiomers was achieved with the analysis time between 1-2 s.


Subject(s)
Chemistry Techniques, Analytical/instrumentation , Chemistry Techniques, Analytical/methods , Chromatography, High Pressure Liquid , Stereoisomerism , Time Factors
19.
J Chromatogr A ; 1557: 62-74, 2018 Jul 06.
Article in English | MEDLINE | ID: mdl-29748092

ABSTRACT

The interplay between structural details of chiral analytes and selectors in the separation of 14 chiral sulfoxides was systematically studied on 18 different polysaccharide-based chiral columns. Retention and enantioselectivity of a set of chiral sulfoxides were of primary interest. Several of chiral columns studied exhibited quite powerful chiral recognition ability in pure methanol. With addition of water to the mobile phase retention increased in the most cases and the separation factor improved. However, several exceptions were also noted. Of monosubstituted phenylcarbamates of cellulose as chiral selectors, chlorosubstituted ones did not show better enantiomer resolving ability compared to unsubstituted cellulose tris(phenylcarbamate). Out of disubstituted phenylcarbamates of cellulose the ones with methylsubstituents showed higher enantiomer resolving ability compared to chloro-substituted ones and substitution in positions 3 and 5 of the phenyl moiety was clearly advantageous. From disubstituted derivatives those possessing a combination of methyl- and chloro-substituents were advantageous compared to the ones having dimethyl- or dichloro-substituents. Interesting examples of reversal in enantiomer elution order (EEO) were observed on cellulose tris(4-chloro-3-methylphenylcarbamate)- and cellulose tris(3-chloro-4-methylphenylcarbamate)-based chiral stationary phases (CSPs) function of the water content in the mobile phase.


Subject(s)
Cellulose/chemistry , Chromatography, High Pressure Liquid/methods , Methanol/chemistry , Sulfoxides/isolation & purification , Water/chemistry , Stereoisomerism , Sulfoxides/chemistry
20.
J Chromatogr A ; 1545: 59-66, 2018 Apr 13.
Article in English | MEDLINE | ID: mdl-29502898

ABSTRACT

The present study reports successful separations of enantiomers of selected chiral sulfoxides with very high separation factor in high-performance liquid chromatography by using chiral columns prepared with the chiral selector cellulose tris(4-chloro-3-methylphenylcarbamate). High separation factors were observed in polar organic, as well as in hydrocarbon-alcohol-type mobile phases. The key structural components of the solute for obtaining high chiral recognition are discussed as well as thermodynamic quantities of analyte adsorption on the chiral stationary phase were determined. Experiment aimed at the enantioselective extraction of racemates from solution are also described.


Subject(s)
Cellulose/analogs & derivatives , Chromatography, High Pressure Liquid/methods , Phenylcarbamates/chemistry , Sulfoxides/chemistry , Sulfoxides/isolation & purification , Adsorption , Cellulose/chemistry , Entropy , Stereoisomerism , Temperature , Time Factors
SELECTION OF CITATIONS
SEARCH DETAIL
...