Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Bioanalysis ; 10(12): 945-955, 2018 Jun 01.
Article in English | MEDLINE | ID: mdl-29939797

ABSTRACT

There has been an increased use of commercial kits for biomarker measurement, commensurate with the increased demand for biomarkers in drug development. However, in most cases these kits do not meet the quality attributes for use in regulated environment. The process for adaptation of these kits can be frustrating, time consuming and resource intensive. In addition, a lack of harmonized guidance for the validation of biomarker poses a significant challenge in the adaptation of kits in a regulated environment. The purpose of this perspective is to propose a tiered approach to commercial drug development kits with clearly defined quality attributes and to demonstrate how these kits can be adapted to perform analytical validation in a regulated environment.


Subject(s)
Biological Assay/standards , Research Design , Validation Studies as Topic , Biomarkers/analysis , Calibration , Drug Discovery , Guidelines as Topic , Humans , Reference Standards , Reproducibility of Results , Sensitivity and Specificity
2.
Bioanalysis ; 6(18): 2385-90, 2014 Sep.
Article in English | MEDLINE | ID: mdl-25384591

ABSTRACT

The topic of incurred sample stability (ISS) has generated considerable discussion within the bioanalytical community in recent years. The subject was an integral part of the seventh annual Workshop on Recent Issues in Bioanalysis (WRIB) held in Long Beach, CA, USA, in April 2013, and at the Global CRO Council for Bioanalysis (GCC) meeting preceding it. Discussion at both events focused on the use of incurred samples for ISS purposes in light of results from a recent GCC survey completed by member companies. This paper reports the consensus resulting from these discussions and serves as a useful reference for depicting ISS issues and concerns, summarizing the GCC survey results and providing helpful recommendations on ISS in the context of bioanalytical method development and application.


Subject(s)
Clinical Chemistry Tests , Data Collection , Reproducibility of Results
4.
AAPS J ; 16(5): 885-93, 2014 Sep.
Article in English | MEDLINE | ID: mdl-24961918

ABSTRACT

Consensus practices and regulatory guidance for liquid chromatography-mass spectrometry/mass spectrometry (LC-MS/MS) assays of small molecules are more aligned globally than for any of the other bioanalytical techniques addressed by the Global Bioanalysis Consortium. The three Global Bioanalysis Consortium Harmonization Teams provide recommendations and best practices for areas not yet addressed fully by guidances and consensus for small molecule bioanalysis. Recommendations from all three teams are combined in this report for chromatographic run quality, validation, and sample analysis run acceptance.


Subject(s)
Chromatography, Liquid/standards , Tandem Mass Spectrometry/standards , Technology, Pharmaceutical/standards , Benchmarking , Calibration , Consensus , Quality Control , Reference Standards , Reproducibility of Results , Technology, Pharmaceutical/methods
SELECTION OF CITATIONS
SEARCH DETAIL
...