1.
Sci Rep ; 13(1): 16956, 2023 10 07.
Article in English | MEDLINE | ID: mdl-37805659

ABSTRACT

The aim was to compare measurements of anterior segment biometry parameters using two Scheimpflug tomographies, Pentacam and Sirius to assess the agreement. Prospective cross-sectional observational study. A total of 60 eyes of 30 healthy subjects were included and evaluated with Pentacam followed by Sirius imaging. Corneal indices were performed with two modalities in both eyes including; apical corneal thickness (ACT), corneal thickness at pupil site(PCT), thinnest corneal thickness (TCT), anterior chamber depth (ACD), chamber angle, chamber volume, cornea volume, mean front keratometry (FKm), the radius of corneal curvature at the anterior and posterior surface in steep and flat meridian, anterior astigmatism values, pupil diameter, and horizontal corneal diameter. The Bland-Altman graph and ICC (intra-class correlation were used to establish an agreement and present the similarity of the findings. Most parameters showed perfect agreement. In both devices, the ICC was more than 0.91 in all measurements except for ACD (ICC = 0.820), cylinder axis (ICC = 0.520), TCT(ICC = 0.881), ACT(ICC = 0.672), PCT (ICC = 0.882), chamber angle (ICC = 0.362), pupil diameter(ICC = 0.137). Pentacam yielded higher values that were significant in five parameters including 3.47 µm for TCT, 4.29 µm for PCT, 10.03 mm3 for chamber volume,2.67 mm3 for cornea volume, and 1.49 mm for pupil diameter but there was only a statistically significant difference in cornea volume and pupil diameter (p-value < 0.001). However, in Pentacam only the chamber angle value was 6.44 mm3 lower than Sirius, with a statistically significant difference (p-value < 0.001). Although these two devices had some statistically different results, it seems that they have a good agreement and correlation in most parameters.


Subject(s)
Astigmatism , Cornea , Humans , Prospective Studies , Cross-Sectional Studies , Reproducibility of Results , Cornea/diagnostic imaging , Corneal Topography/methods
2.
Int Ophthalmol ; 43(6): 1877-1888, 2023 Jun.
Article in English | MEDLINE | ID: mdl-36418807

ABSTRACT

PURPOSE: To evaluate the effects of ocular biometric variables on corneal biomechanical properties. METHODS: A total of 102 eyes of 102 participants were enrolled in this cross-sectional study. The axial length (AL) was determined by an IOL master 500 and measurements of corneal biomechanical properties were performed using Corvis ST, integrated with pentacam results. RESULTS: Aging and corneal steepening were associated with less corneal deformability and higher movement of the entire eye. Longer AL corresponded with greater deformability and lower corneal viscous damping properties and less whole eye movement (all P-values < 0.05). In contrast to mean keratometry (Mean K) and corneal diameter, anterior chamber depth (ACD) and AL have a significant effect on corneal biomechanical parameters. Corneal biomechanical index (CBI) was not significantly correlated with any of biometric parameters. Stress-strain index (SSI) was significantly correlated with age (r = 0.470), spherical equivalent (SE) (r = 0.537), AL (r = -0.534) and ACD (r = -0.316) (all P-values < 0.001). CONCLUSIONS: In normal individuals, several parameters such as age, ACD, AL and Mean K have a great impact on corneal biomechanical properties; thereby, these effects should be taken into account prior to interpretation of corneal biomechanics, particularly in older ages and eyes with longer AL and steeper cornea.


Subject(s)
Cornea , Refraction, Ocular , Humans , Cross-Sectional Studies , Aging , Biometry/methods , Biomechanical Phenomena
3.
Saudi J Ophthalmol ; 33(1): 24-27, 2019.
Article in English | MEDLINE | ID: mdl-30930659

ABSTRACT

BACKGROUND: Degenerative biomechanical factors and immunologic processes with effect on collagen and corneal reparative process are known as the main cause of ocular surface dysfunction in mustard gas keratopathy (MGK) and may cause changes in the corneal biomechanical values. Therefore, we evaluate corneal biomechanical properties of these patients. METHODS AND MATERIALS: This case-control study includes 61 chemical warfare victims with MGK. After omission according to our exclusion criteria, 88 eyes of patients with MGK were enrolled as the case group and also a group of 88 normal eyes, which were matched regarding their age and sex in the control group, were enrolled. Measurements of corneal biomechanical properties which reported by ORA and Corvis ST (CST) devices were compared. The SPSS software version 23.0 was used in the statistical analysis. For comparisons between groups, if the data had a normal distribution, were analyzed by Student's t-test and ANOVA, and if the data didn't have a normal distribution, Mann-Whitney U test, and Kruskal-Wallis were used. Furthermore, to identify a relationship between two groups of data Spearman's rank Correlation test was used. P value < 0.05 were considered statistically significant. RESULTS: In the MGK group, A1 length (A1L), A1 velocity (A1V), A2 velocity (A2V), deformation amplitude (DA) and peak distance (PD) were higher than the control group (P < 0.001). However, the corneal hysteresis (CH) (P = 0.003), corneal resistant factor (CRF), non-corrected IOP (IOPnct), corrected IOP based on corneal thickness (IOPpachy), and central corneal thickness (CCT) were lower than the control group (P < 0.001). The visual acuity according to the LogMAR scale and severity of MGK was positively associated with IOPpachy and negatively associated with CH, CRF, CCT and highest concavity radius (Radius). CONCLUSION: Measurement of corneal biomechanical properties may be, have a useful role in the classification, monitoring or diagnosis of MGK.

4.
Ocul Oncol Pathol ; 4(3): 165-169, 2018 Apr.
Article in English | MEDLINE | ID: mdl-29765948

ABSTRACT

Rhabdomyosarcoma (RMS) is the most common malignant tumor of the orbit in children, but it is rarely present at birth. We report a large congenital orbital RMS with intracranial extension in a newborn baby. A newborn baby girl was referred to our hospital due to severe right-eye exophthalmia. Imaging studies showed an orbital mass with intracranial extension. Treatment was started with a course of neoadjuvant chemotherapy followed by right orbital exenteration and intracranial resection of the tumor. Histologic examination of the mass showed undifferentiated malignant small-cell tumor. Immunohistochemical study proved it to be RMS. The patient was categorized as intermediate-risk RMS and chemotherapy was continued accordingly with VAC regimen. In spite of treatment, the infant developed intracranial recurrence at the age of 6 months and died 1 month later. Congenital orbital RMS has a poor prognosis. Reconstruction surgery should be deferred due to high rate of recurrence and low chance of survival. A multidisciplinary approach might increase the survival of these patients.