Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 3 de 3
Filter
Add more filters










Database
Language
Publication year range
1.
Eur Heart J Open ; 2(3): oeac032, 2022 May.
Article in English | MEDLINE | ID: mdl-35919340

ABSTRACT

Aims: Peripheral arterial disease (PAD) is a major public health burden requiring more intensive population screening. Ankle brachial index (ABI) using arm and ankle cuffs is considered as the reference method for the detection of PAD. Although it requires a rigorous methodology by trained operators, it remains time-consuming and more technically difficult in patients with diabetes due to mediacalcosis. Techniques based on the study of hemodynamic, such as the systolic rise time (SRT), appear promising but need to be validated. We retrospectively compared the reliability and accuracy of SRT using a photoplethysmography (PPG) technique to the SRT measured by ultrasound doppler (UD) in PAD patients diagnosed with the ABI (137 patients, 200 lower limbs). Methods and results: There was a significant correlation between SRT measured with UD (SRTud) compared with that with PPG (SRTppg, r = 0.25; P = 0.001). Best correlation was found in patients without diabetes (r = 0.40; P = 0.001). Bland and Altman analysis showed a good agreement between the SRTud and SRTppg. In contrast, there was no significant correlation between UD and PPG in diabetes patients. Furthermore, patients with diabetes exhibited a significant increase of SRTppg (P = 0.02) compared with patients without diabates but not with the SRTud (P = 0.18). The SRTppg was significantly linked to the arterial velocity waveforms, the type of arterial lesion but not vascular surgery revascularization technique. Conclusion: This monocentric pilot study shows that SRT measured with the PPG signal reliably correlates with SRT recorded with UD. The PPG is an easy to use technique in the hand of non-expert with a potential interest for general screening of PAD, especially in diabetes patients, due to its ease to use.

2.
JAMA Dermatol ; 157(2): 202-206, 2021 02 01.
Article in English | MEDLINE | ID: mdl-33237291

ABSTRACT

Importance: Chilblain-like lesions have been reported during the coronavirus 2019 (COVID-19) pandemic. The pathophysiology of such manifestations remains largely unknown. Objective: To perform a systematic clinical, histologic, and biologic assessment in a cohort of patients with chilblain-like lesions occurring during the COVID-19 pandemic. Design, Setting, and Participants: In this prospective case series carried out with a COVID-19 multidisciplinary consultation group at the University Hospital of Nice, France, 40 consecutive patients presenting with chilblain-like lesions were included. Main Outcomes and Measures: Patients underwent a thorough general and dermatologic examination, including skin biopsies, vascular investigations, biologic analyses, interferon-alpha (IFN-α) stimulation and detection, and severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) polymerase chain reaction (PCR) and serologic analysis. Results: Overall, 40 consecutive patients with chilblain-like lesions were included. Most patients were young, with a median (range) age of 22 (12-67) years; 19 were male and 21 were female. The clinical presentation was highly reproducible with chilblain-like lesions mostly on the toes. Bullous and necrotic evolution was observed in 11 patients. Acrocyanosis or cold toes were reported in 19 (47.5%) cases. Criteria compatible with COVID-19 cases were noted in 11 (27.5%) within 6 weeks prior to the eruption. The real-time PCR (rt-PCR) testing results were negative in all cases. Overall, SARS-CoV-2 serology results were positive in 12 patients (30%). D-dimer concentration levels were elevated in 24 (60.0%) cases. Cryoglobulinemia and parvovirus B19 serologic results were negative for all tested patients. The major histologic findings were features of lymphocytic inflammation and vascular damage with thickening of venule walls and pericyte hyperplasia. A significant increase of IFN-α production after in vitro stimulation was observed in the chilblain population compared with patients with mild-severe acute COVID-19. Conclusions and Relevance: Taken together, our results suggest that chilblain-like lesions observed during the COVID-19 pandemic represent manifestations of a viral-induced type I interferonopathy. Trial Registration: ClinicalTrials.gov Identifier: NCT04344119.


Subject(s)
COVID-19/complications , Chilblains/etiology , Adolescent , Adult , Aged , COVID-19/immunology , Chilblains/immunology , Child , Female , Humans , Interferon-alpha/immunology , Male , Middle Aged , Prospective Studies , Young Adult
3.
J Endovasc Ther ; 14(3): 416-20, 2007 Jun.
Article in English | MEDLINE | ID: mdl-17723012

ABSTRACT

PURPOSE: To report a technique for fenestrated stent-graft repair involving a conduit implanted at the origin of a patent aneurysmal common iliac artery (CIA) in a patient with a pararenal aortic aneurysm and iliac artery occlusion. CASE REPORT: A 60-year-old man with multiple comorbidities presented with an 8-cm abdominal aortic aneurysm (AAA) with no infrarenal neck according to computed tomography (CT). Both CIAs were aneurysmal; the left was occluded, as were the left internal and external iliac arteries and the inferior mesenteric artery. Two patent accessory renal arteries were depicted. Because an infrarenal neck was absent, treatment with a fenestrated endograft was performed under general anesthesia. The right CIA was approached via an oblique retroperitoneal incision. A 10-mm polytetrafluoroethylene tube graft was implanted on the origin of the right CIA aneurysm in an end-to-side fashion to facilitate delivery of a Zenith endograft constructed with 2 small fenestrations for the renal arteries, 1 large strut-free fenestration for the superior mesenteric artery, and a scallop for the celiac trunk. The proximal fenestrated body of the Zenith device was introduced via the right iliac artery by direct puncture of the common femoral artery. The conduit was used to cannulate the 3 fenestrations for subsequent deployment and for delivery of the distal Zenith aortomonoiliac device. The procedure was completed successfully, but 12 hours after surgery, the patient developed a significant right retroperitoneal hematoma, which was treated surgically. CT confirmed patency of all visceral arteries and no endoleak. One month after the initial procedure, he had recovered totally and was discharged. CONCLUSION: Iliac conduits could widen the feasibility of fenestrated endografting in patients unfit for open surgery with pararenal aneurysms and challenging iliac anatomy. However, this adjunctive procedure has its own morbidity.


Subject(s)
Aortic Aneurysm, Abdominal/surgery , Blood Vessel Prosthesis Implantation/instrumentation , Blood Vessel Prosthesis , Iliac Aneurysm/surgery , Renal Artery/surgery , Stents , Viscera/blood supply , Anastomosis, Surgical , Aortic Aneurysm, Abdominal/complications , Aortic Aneurysm, Abdominal/diagnostic imaging , Aortic Aneurysm, Abdominal/physiopathology , Arteries/surgery , Humans , Iliac Aneurysm/complications , Iliac Aneurysm/diagnostic imaging , Iliac Aneurysm/physiopathology , Male , Middle Aged , Polytetrafluoroethylene , Prosthesis Design , Renal Artery/diagnostic imaging , Renal Artery/physiopathology , Tomography, X-Ray Computed , Treatment Outcome , Vascular Patency
SELECTION OF CITATIONS
SEARCH DETAIL
...