Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 16 de 16
Filter
2.
Pediatr Pulmonol ; 59(4): 855-862, 2024 Apr.
Article in English | MEDLINE | ID: mdl-38353403

ABSTRACT

BACKGROUND: Diaphragm dysfunction is associated with poor outcomes in critically ill patients. Ventilator-induced diaphragmatic dysfunction (VIDD), including diaphragm atrophy (DA), is poorly studied in newborns. We aimed to assess VIDD and its associations in newborns. METHODS: Single-center prospective study. Diaphragm thickness was measured at end-inspiration (TDI) and end-expiration (TDE) on the right midaxillary line. DA was defined as decrease in TDE ≥ 10%. Daily measurements were recorded in preterm newborns on invasive mechanical ventilation (IMV) for ≥2 days. Clinical characteristics of patients and extubation failure were recorded. Univariate analysis, logistic regression, and mixed models were performed to describe VIDD and associated factors. RESULTS: We studied 17 patients (median gestational age 270/7 weeks) and 22 IMV cycles (median duration 9 days). Median TDE decreased from 0.118 cm (interquartile range [IQR] 0.094-0.165) on the first IMV day to 0.104 cm (IQR 0.083-0.120) on the last IMV day (p = .092). DA occurred in 11 IMV cycles (50%) from 10 infants early during IMV (median: second IMV day). Mean airway pressure (MAP) and lung ultrasound score (LUS) on the first IMV day were significantly higher in patients who developed DA. DA was more frequent in patients with extubation failure than in those with extubation success within 7 days (83.3 vs. 33.3%, p = .038). CONCLUSIONS: DA, significantly associated with extubation failure, occurred in 58.8% of the study infants on IMV. Higher MAP and LUS at IMV start were associated with DA. Our results suggest a potential role of diaphragm ultrasound to assess DA and predict extubation failure in clinical practice.


Subject(s)
Respiration, Artificial , Ventilator Weaning , Infant , Humans , Infant, Newborn , Respiration, Artificial/adverse effects , Respiration, Artificial/methods , Ventilator Weaning/methods , Prospective Studies , Diaphragm/diagnostic imaging , Airway Extubation/adverse effects , Airway Extubation/methods , Infant, Premature , Atrophy/pathology
4.
Int J Gynaecol Obstet ; 165(3): 1040-1046, 2024 Jun.
Article in English | MEDLINE | ID: mdl-38108543

ABSTRACT

OBJECTIVE: To evaluate whether acute histologic chorioamnionitis (HCA) diagnosed in the placenta may be associated with an increased occurrence of bronchopulmonary dysplasia (BPD) or death among extremely low gestational age neonates (ELGAN). METHODS: This Italian single-center case-control retrospective study involved ELGAN admitted to the neonatal intensive care unit between January 2019 and June 2022. Infants born from pregnant women with acute and severe HCA, identified as stage ≥2 and grade 2 HCA, (HCA-infants) were compared with infants of pregnant women without chorioamnionitis or with stage 1, grade 1 chorioamnionitis (no-HCA-infants). RESULTS: Among 101 eligible ELGAN, 63 infants had complete clinical and histologic data relevant to the study: thirty infants were included in the HCA-infants group and 33 in the no-HCA-infants group. Neonatal and maternal demographic and clinical characteristics were similar between the two groups. Infants born from mothers with acute and severe HCA had significantly higher occurrence of composite BPD or death (18 [60%] vs. 9 [27%]; P = 0.012), as well as higher incidence of severe forms of BPD (6 [30%] vs. 2 [6%]; P = 0.045). In multiple logistic regression analysis, after adjustment for confounding covariates, HCA was an independent risk factor for BPD or death (OR, 4.49; 95% CI: 1.47-13.71). CONCLUSIONS: This is the first study showing that in utero exposure to acute and severe HCA is an independent risk factor for the occurrence of composite BPD or death among ELGAN.


Subject(s)
Bronchopulmonary Dysplasia , Chorioamnionitis , Humans , Female , Bronchopulmonary Dysplasia/epidemiology , Bronchopulmonary Dysplasia/mortality , Chorioamnionitis/epidemiology , Retrospective Studies , Pregnancy , Infant, Newborn , Case-Control Studies , Adult , Italy/epidemiology , Infant, Extremely Premature , Male , Intensive Care Units, Neonatal , Risk Factors , Gestational Age , Infant Mortality
5.
Children (Basel) ; 10(11)2023 Oct 30.
Article in English | MEDLINE | ID: mdl-38002852

ABSTRACT

BACKGROUND: Tactile stimulation manoeuvres stimulate spontaneous breathing in preterm newborns. The aim of this study is to evaluate the effect of early respiratory physiotherapy on the need for mechanical ventilation during the first week of life in preterm infants with respiratory failure. METHODS: This is a monocentric, randomised controlled trial. Preterm infants (gestational age ≤ 30 weeks) not intubated in the delivery room and requiring non-invasive respiratory support at birth were eligible for the study. The intervention group received early respiratory physiotherapy, while the control group received only a daily physiotherapy program (i.e., modifying the infant's posture in accordance with the patient's needs). RESULTS: between October 2019 and March 2021, 133 preterm infants were studied, 68 infants in the study group and 65 in routine care. The study group showed a reduction in the need for mechanical ventilation (not statistically significant) and a statistically significant reduction in hemodynamically significant patent ductus arteriosus with respect to the control group (19/68 (28%) vs. 35/65 (54%), respectively, p = 0.03). CONCLUSIONS: early respiratory physiotherapy in preterm infants requiring non-invasive respiratory support at birth is safe and has proven to be protective against haemodynamically significant PDA.

6.
J Clin Med ; 12(20)2023 Oct 17.
Article in English | MEDLINE | ID: mdl-37892703

ABSTRACT

Intrahepatic cholestasis of pregnancy (ICP) complicates among 0.2-2% of pregnancies and has been associated with adverse perinatal outcomes, including sudden stillbirth, meconium strained fluid, preterm birth, perinatal asphyxia, and transient tachypnea of the newborn. The diagnosis of "bile acids pneumonia" was previously proposed and a causative role of bile acids (BA) was supposed with a possible mechanism of action including surfactant dysfunction, inflammation, and chemical pneumonia. In the last few years, the role of lung ultrasound (LUS) in the diagnosis and management of neonatal respiratory distress syndrome has grown, and LUS scores have been introduced in the literature, as an effective predictor of the need for surfactant treatment among neonates with respiratory distress syndrome. We present four cases of infants born from pregnancies complicated by ICP, who developed respiratory distress syndrome early after birth. Lung ultrasound showed the same pattern for all infants, corresponding to a homogeneous alveolar-interstitial syndrome characterized by a diffuse coalescing B-line pattern (white lung). All infants evaluated require non-invasive respiratory support and in three cases surfactant administration, despite the near-term gestational age, with rapid improvement of respiratory disease and a good clinical outcome.

7.
J Pediatr ; 260: 113517, 2023 09.
Article in English | MEDLINE | ID: mdl-37244573

ABSTRACT

OBJECTIVE: To evaluate the role of cyanoacrylate glue in reducing dislodgement of umbilical venous catheters (UVCs). STUDY DESIGN: This was a single-center, randomized, controlled, nonblinded trial. All infants requiring an UVC according to our local policy were included in the study. Infants with a UVC with a centrally located tip as verified by real-time ultrasound examination were eligible for the study. Primary outcome was the safety and efficacy of securement by cyanoacrylate glue plus cord-anchored suture (SG group) vs securement by suture alone (S group), as measured by reduction in dislodgment of the external tract of the catheter. Secondary outcomes were tip migration, catheter-related bloodstream infection, and catheter-related thrombosis. RESULTS: In the first 48 hours after UVC insertion, dislodgement was significantly higher in the S group than in the SG group (23.1% vs 1.5%; P < .001). The overall dislodgement rate was 24.6% in the S group vs 7.7% in the SG group (P = .016). No differences were found in catheter-related bloodstream infection and catheter-related thrombosis. The incidence of tip migration was similar in both groups (S group 12.2% vs SG group 11.7%). CONCLUSIONS: In our single-center study, cyanoacrylate glue was safe and effective for securement of UVCs, and particularly effective in decreasing early catheter dislodgments. TRIAL REGISTRATION: UMIN-CTR Clinical Trial; Registration number: R000045844.


Subject(s)
Catheter-Related Infections , Catheterization, Central Venous , Catheterization, Peripheral , Sepsis , Thrombosis , Vascular Diseases , Infant , Humans , Cyanoacrylates/therapeutic use , Catheters , Veins , Umbilical Veins
8.
Am J Perinatol ; 2023 May 19.
Article in English | MEDLINE | ID: mdl-37075786

ABSTRACT

OBJECTIVE: During the early weeks of life optimization of nutrition in extremely preterm infants presents a critical opportunity to attenuate the adverse neurological consequences of prematurity and potentially improve neurodevelopmental outcome. We hypothesized that the use of multicomponent lipid emulsion (MLE) in parenteral nutrition (PN) would be related to larger volume of the cerebellum on brain magnetic resonance at term of equivalent age (TEA) in extremely low birth weight (ELBW) infants. STUDY DESIGN: We analyzed the brain magnetic resonance imaging (MRI) at TEA of a cohort of preterm infants with gestational age ≤28 weeks and/or birth weight <1,000 g randomly assigned in our previous trial to receive an MLE or soybean-based lipid emulsion (SLE). The primary outcome of the study was the cerebellar volume (CeV), valued on MRI acquired at TEA. Secondary outcomes included total brain volume (TBV), supratentorial volume, brainstem volume, and CeV corrected for TBV evaluated on MRI acquired at TEA. RESULTS: MRIs at TEA of 34 infants were then analyzed: 17 in the MLE group and 17 in the SLE group. The postmenstrual age (PMA) at which MRIs were performed were comparable between the two study groups. The CeV as well as the PMA-corrected CeV were significantly higher in the MLE group than in the SLE group. No difference was found among the other brain volumes considered. CONCLUSION: Our results suggest that the use of MLE in PN could promote CeV growth in ELBW infants, valued with MRI at TEA. KEY POINTS: · Optimization of nutrition in extremely low birthweight infants.. · Use of multicomponent lipid emulsions in parenteral nutrition.. · Larger cerebellar volume with use of multicomponent lipid emulsion..

9.
Children (Basel) ; 10(3)2023 Mar 10.
Article in English | MEDLINE | ID: mdl-36980093

ABSTRACT

Extremely preterm infants frequently require some form of respiratory assistance to facilitate the cardiopulmonary transition that occurs in the first hours of life. Current resuscitation guidelines identify as a primary determinant of overall newborn survival the establishment, immediately after birth, of adequate lung inflation and ventilation to ensure an adequate functional residual capacity. Any respiratory support provided, however, is an important contributing factor to the development of bronchopulmonary dysplasia. The risks correlated to invasive ventilatory techniques increase inversely with gestational age. Preterm infants are born at an early stage of lung development and are more susceptible to lung injury deriving from mechanical ventilation. Any approach aiming to reduce the global burden of preterm lung disease must implement lung-protective ventilation strategies that begin from the newborn's first breaths in the delivery room. Neonatologists today must be able to manage both invasive and noninvasive forms of respiratory assistance to treat a spectrum of lung diseases ranging from acute to chronic conditions. We searched PubMed for articles on preterm infant respiratory assistance. Our narrative review provides an evidence-based overview on the respiratory management of preterm infants, especially in the acute phase of neonatal respiratory distress syndrome, starting from the delivery room and continuing in the neonatal intensive care unit, including a section regarding exogenous surfactant therapy.

10.
Ital J Pediatr ; 49(1): 35, 2023 Mar 21.
Article in English | MEDLINE | ID: mdl-36945009

ABSTRACT

BACKGROUND: To date, no studies on presepsin values in cord blood of term infants with risk factors for early-onset sepsis (EOS) are available, whereas only one study reported presepsin values in cord blood of preterm infants at risk. In this study, we investigated the presepsin values in cord blood of term and preterm infants with documented risk factors for EOS. METHODS: In this single-center prospective pilot study, we enrolled neonates presenting with documented risk factors for EOS. P-SEP levels were assessed in a blood sample collected from the clamped umbilical cord after the delivery in 93 neonates, using a point-of-care device. The primary outcome of our study was to evaluate the role of cord blood P-SEP in predicting clinical EOS in term and preterm infants. RESULTS: During the study period, we enrolled 93 neonates with risk factors for EOS with a gestational age ranging between 24.6 and 41.6 weeks (median 38.0). The median P-SEP value in all infants was 491 pg/ml (IQR 377 - 729). Median cord P-SEP values were significantly higher in infants with clinical sepsis (909 pg/ml, IQR 586 - 1307) rather than in infants without (467 pg/ml, IQR 369 - 635) (p = 0.010). We found a statistically significant correlation between cord P-SEP value at birth and the later diagnosis of clinical sepsis (Kendall's τ coefficient 0.222, p = 0.002). We identified the maximum Youden's Index (best cut-off point) at 579 pg/ml, corresponding to a sensitivity of 87.5% and a specificity of 71.8% in predicting clinical sepsis. CONCLUSIONS: Maximum Youden's index was 579 pg/ml for clinical EOS using cord P-SEP values. This could be the starting point to realize multicenter studies, confirming the feasibility of dosing P-SEP in cord blood of infants with risk factors of EOS to discriminate those who could develop clinical sepsis and spare the inappropriate use of antibiotics.


Subject(s)
Fetal Blood , Infant, Premature , Lipopolysaccharide Receptors , Neonatal Sepsis , Peptide Fragments , Term Birth , Female , Humans , Infant , Infant, Newborn/blood , Biomarkers/blood , Fetal Blood/chemistry , Infant, Premature/blood , Lipopolysaccharide Receptors/blood , Neonatal Sepsis/blood , Neonatal Sepsis/diagnosis , Peptide Fragments/blood , Pilot Projects , Prospective Studies , Sepsis/blood , Sepsis/diagnosis , Term Birth/blood , Risk Factors
11.
Diagnostics (Basel) ; 13(4)2023 Feb 14.
Article in English | MEDLINE | ID: mdl-36832209

ABSTRACT

MAS is a common cause of neonatal respiratory distress in term and post-term neonates. Meconium staining of the amniotic fluid occurs in about 10-13% of normal pregnancies, and about 4% of these infants develop respiratory distress. In the past, MAS was diagnosed mainly on the basis of history, clinical symptoms, and chest radiography. Several authors have addressed the ultrasonographic assessment of the most common respiratory patterns in neonates. In particular, MAS is characterised by a heterogeneous alveolointerstitial syndrome, subpleural abnormalities with multiple lung consolidations, characterised by a hepatisation aspect. We present six cases of infants with a clinical history of meconium-stained fluid who presented with respiratory distress at birth. Lung ultrasound allowed the diagnosis of MAS in all the studied cases, despite the mild clinical picture. All children had the same ultrasound pattern with diffuse and coalescing B-lines, pleural line anomalies, air bronchograms, and subpleural consolidations with irregular shapes. These patterns were distributed in different areas of the lungs. These signs are specific enough to distinguish between MAS and other causes of neonatal respiratory distress, allowing the clinician to optimise therapeutic management.

12.
Am J Perinatol ; 2023 Jan 24.
Article in English | MEDLINE | ID: mdl-36693387

ABSTRACT

OBJECTIVE: In this study, we evaluated the safety of early discharge (ED) of newborns born to coronavirus disease 2019 (COVID-19)-positive mothers. STUDY DESIGN: All ED newborns from the postpartum wards of the Fondazione Policlinico Gemelli between January 1, 2022, and February 28, 2022, were retrospectively analyzed. Newborns from mothers with COVID-19 and those from uninfected mothers were considered. The primary outcome was to evaluate whether the rate of the composite outcome, which was the percentage of rehospitalization/access in emergency room (RH/ER) within the first week from discharge, differed between neonates born to mother with COVID-19 (COVID-19 group) and those born to uninfected mothers (no COVID-19 group). The secondary outcomes were to assess the quality of feeding and number of outpatient visits in the follow-up clinic between the two cohorts of patients. RESULTS: One hundred and thirty-four newborns in the no COVID-19 group and 26 in the COVID-19 group were analyzed. The rate of RH/ER in the no COVID-19 group was of 6 over 134 newborns (0.045, 95% confidence image [CI]: 0.017-0.095), while in COVID-19 group, it was of 2 over 26 newborns (0.077), which does not differ from the expected rate (1.17 over 26 newborns, 0.045, 95% CI: 0.017-0.095). CONCLUSION: ED for newborns from mothers with COVID-19 could be an actionable safe strategy. KEY POINTS: · We evaluated the feasibility of early discharge (ED) of mothers with COVID-19 and their newborns.. · Rate of rehospitalization between newborns from uninfected mothers and infected ones was comparable.. · ED could be an actionable practice for newborns from mothers with COVID-19..

13.
Diagnostics (Basel) ; 12(8)2022 Aug 07.
Article in English | MEDLINE | ID: mdl-36010259

ABSTRACT

Respiratory distress (RD) is one of the most common causes of admission to the neonatal intensive care unit. Correct diagnosis and timely intervention are crucial. Lung ultrasonography (LU) is a useful diagnostic tool for the neonatologist in the diagnosis of RD; the neonatal lung ultrasonography score (nLUS) can be used in the diagnostic process, but some authors hypothesise that it is also useful for the management of some neonatal RD. The aim of this study is to analyse the changes in nLUS score before (T0) and after (T1) the start of respiratory support with nasal CPAP in neonates over 32 weeks of age with RD. Thirty-three newborns were enrolled in this retrospective study. LU was performed before and after the start of CPAP. The median nLUS scores at T0 and T1 were 9 (IQR 7−12) and 7 (IQR 4−10), respectively, and showed a significant difference (p < 0.001). The magnitude of reduction in nLUS score, expressed as a percentage, was inversely related to the need for subsequent administration of exogenous surfactant. The study suggests the usefulness of the nLUS score in assessing the response to CPAP in neonates over 32 weeks gestational age.

14.
Clin Chem Lab Med ; 60(9): 1486-1491, 2022 08 26.
Article in English | MEDLINE | ID: mdl-35748906

ABSTRACT

OBJECTIVES: Coronavirus disease (COVID-19) can present with various symptoms and can involve multiple organs. Women infected during pregnancy have a higher incidence of obstetrical complications and infants born to "positive" mothers may get the infection with different manifestations. Presepsin seems to be a promising sepsis biomarker in adults and neonates. The aim of this study was to assess if presepsin levels in neonatal cord blood could be influenced by maternal severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection. METHODS: A total of 119 neonates born from women with a confirmed diagnosis of SARS-CoV-2 infection were enrolled and presepsin levels of cord blood samples were collected. All neonates were tested for SARS-CoV-2 infection at birth and after 48-72 h. RESULTS: The median presepsin value in umbilical cord blood samples collected after birth was 455 pg/mL. Presepsin levels were not influenced by maternal symptoms of COVID-19, weight for gestational age, or delivery mode, and did not significantly differ between infants with and without adverse neonatal outcomes. Infants hospitalized for more than 5 days had a significantly higher presepsin level at birth rather than those discharged up to 4 days of life. Three infants with positive nasopharyngeal swab at birth had higher Presepsin levels than two infants tested positive at 48 h. CONCLUSIONS: This is the first study reporting cord presepsin levels in term and preterm infants born to mothers with COVID-19, that appeared to be not influenced by maternal clinical presentation. However, further studies are needed to explain the mechanisms of P-SEP increase in neonates exposed to perinatal maternal SARS-CoV-2 infection or with an indeterminate/possible SARS-CoV-2 infection in the same neonates.


Subject(s)
COVID-19 , Adult , COVID-19/diagnosis , Female , Fetal Blood , Humans , Infant, Newborn , Infant, Premature , Infectious Disease Transmission, Vertical , Lipopolysaccharide Receptors , Peptide Fragments , Pregnancy , SARS-CoV-2
15.
J Hum Lact ; 38(3): 443-451, 2022 08.
Article in English | MEDLINE | ID: mdl-35272513

ABSTRACT

BACKGROUND: The Coronavirus disease 2019 (COVID-19) pandemic emerged in December 2019 and spread rapidly worldwide. So far, evidence regarding the breastfeeding and rooming-in management of mothers with COVID-19 and their newborn infants is scarce. RESEARCH AIMS: 1) To assess the rate of exclusive breastfeeding at discharge among mothers with COVID-19 and their newborn infants managed either using a rooming-in or a separation regimen; and 2) to evaluate different neonatal outcomes, including the need for re-hospitalization related to COVID-19 among newborn infants in the two groups. METHOD: We conducted a retrospective two-group comparative observational study. The sample was participants with COVID-19 and their newborn infants (N = 155 dyads) between March 1, 2020, and April 30, 2021. Two time periods were outlined resulting from the two different clinical practices of mother-infant separation and rooming-in. RESULTS: Within the sample, 145 (93.5%) were asymptomatic. All neonates had documented Severe Acute Respiratory Syndrome Coronavirus 2 (SARS-CoV-2) test results, and six tested positive by reverse transcriptase polymerase chain reaction within 48 hr of life. The rate of exclusive breastfeeding was significantly higher (p < .0001) within the rooming-in group. Length of hospital stay was significantly lower (p = .001) within the rooming-in group. CONCLUSIONS: Protected rooming-in practice has proven to be safe and effective in supporting breastfeeding: None of the infants enrolled were hospitalized due to COVID-19 infection and the rate of exclusive breastfeeding at discharge was increased compared to those infants separated from their mothers.


Subject(s)
COVID-19 , Pandemics , Breast Feeding , COVID-19/epidemiology , Female , Humans , Infant , Infant, Newborn , Pandemics/prevention & control , Retrospective Studies , SARS-CoV-2
16.
Am J Perinatol ; 2022 May 17.
Article in English | MEDLINE | ID: mdl-35263767

ABSTRACT

OBJECTIVE: The extent of vertical transmission (VT) of severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) from mothers their fetuses or neonates is still uncertain. We aimed to determine the incidence of VT. STUDY DESIGN: In this prospective cohort study. All mother diagnosed with SARS-CoV-2 infection at the time of delivery or up to 1 week prior and their neonates, managed in a tertiary referral hospital for pregnancy complicated by coronavirus disease 2019 (COVID-19) in Rome, from April 2 to December 22, 2020, were included. Maternal infection was defined as nasopharyngeal swab test results positive for SARS-CoV-2 reverse transcription-polymerase chain reaction (RT-PCR). Biological samples were collected before, at, and after delivery to test positivity for SARS-CoV-2 RT-PCR and anti-SARS-CoV-2-specific antibodies. RESULTS: The cohort included 95 women and 96 neonates with documented SARS-CoV-2 test results. Four neonates (4.2%) tested positive. The incidence of VT, according to the guidance criteria for diagnosing perinatal SARS-CoV-2 infection, was 5.2%. Neonatal symptoms were due to prematurity or fetal distress: symptomatic infants had lower median (min-max) gestational age, 38.1 (29.3-40.6) versus 39.3 (33.9-41.9) weeks (p = 0.036), and 1-minute and 5-minute Apgar scores, 9 (3-9) versus 9 (7-10) (p = 0.036) and 10 (6-10) versus 10 (8-10) (p = 0.012), respectively, than asymptomatic infants and needed more frequent assistance in the delivery room (22.2 vs 2.5%; p = 0.008). Only six (7.1%) neonates had anti-SARS-CoV-2-specific antibodies, despite the ongoing maternal infection. CONCLUSION: The incidence of VT is low as is the detection of specific anti-SARS-CoV-2 antibodies in cord blood when infection is contracted late in pregnancy. This would suggest poor protection of infants against horizontal transmission of the virus. KEY POINTS: · VT of SARS-CoV-2 from pregnant mothers to fetuses or neonates can be possible.. · In this prospective cohort study, the incidence of VT is found to be 5.2%.. · VT is low but exists..

SELECTION OF CITATIONS
SEARCH DETAIL
...