Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
IEEE Trans Med Imaging ; 34(3): 707-15, 2015 Mar.
Article in English | MEDLINE | ID: mdl-24759983

ABSTRACT

High resistivity gallium arsenide is considered a suitable sensor material for spectroscopic X-ray imaging detectors. These sensors typically have thicknesses between a few hundred µm and 1 mm to ensure a high photon detection efficiency. However, for small pixel sizes down to several tens of µm, an effect called charge sharing reduces a detector's spectroscopic performance. The recently developed Medipix3RX readout chip overcomes this limitation by implementing a charge summing circuit, which allows the reconstruction of the full energy information of a photon interaction in a single pixel. In this work, we present the characterization of the first Medipix3RX detector assembly with a 500 µm thick high resistivity, chromium compensated gallium arsenide sensor. We analyze its properties and demonstrate the functionality of the charge summing mode by means of energy response functions recorded at a synchrotron. Furthermore, the imaging properties of the detector, in terms of its modulation transfer functions and signal-to-noise ratios, are investigated. After more than one decade of attempts to establish gallium arsenide as a sensor material for photon counting detectors, our results represent a breakthrough in obtaining detector-grade material. The sensor we introduce is therefore suitable for high resolution X-ray imaging applications.


Subject(s)
Spectrometry, X-Ray Emission/instrumentation , Spectrometry, X-Ray Emission/methods , Tomography, X-Ray Computed/methods , Arsenicals/pharmacology , Cadmium Compounds/pharmacology , Gallium/pharmacology , Humans , Photons , Principal Component Analysis , Tellurium/pharmacology
2.
Opt Express ; 22(20): 24507-15, 2014 Oct 06.
Article in English | MEDLINE | ID: mdl-25322026

ABSTRACT

The dark-field image obtained in grating-based x-ray phase-contrast imaging can provide information about the objects' microstructures on a scale smaller than the pixel size even with low geometric magnification. In this publication we demonstrate that the dark-field image quality can be enhanced with an energy-resolving pixel detector. Energy-resolved x-ray dark-field images were acquired with a 16-energy-channel photon-counting pixel detector with a 1 mm thick CdTe sensor in a Talbot-Lau x-ray interferometer. A method for contrast-noise-ratio (CNR) enhancement is proposed and validated experimentally. In measurements, a CNR improvement by a factor of 1.14 was obtained. This is equivalent to a possible radiation dose reduction of 23%.

3.
Phys Med Biol ; 59(20): 6195-213, 2014 Oct 21.
Article in English | MEDLINE | ID: mdl-25255737

ABSTRACT

Spectroscopic x-ray imaging based on pixellated semiconductor detectors can be sensitive to charge sharing and K-fluorescence, depending on the sensor material used, its thickness and the pixel pitch employed. As a consequence, spectroscopic resolution is partially lost. In this paper, we study a new detector ASIC, the Medipix3RX, that offers a novel feature called charge summing, which is established by making adjacent pixels communicate with each other. Consequently, single photon interactions resulting in multiple hits are almost completely avoided. We investigate this charge summing mode with respect to those of its imaging properties that are of interest in medical physics and benchmark them against the case without charge summing. In particular, we review its influence on spectroscopic resolution and find that the low energy bias normally present when recording energy spectra is dramatically reduced. Furthermore, we show that charge summing provides a modulation transfer function which is almost independent of the energy threshold setting, which is in contrast to approaches common so far. We demonstrate that this property is directly linked to the detective quantum efficiency, which is found to increase by a factor of three or more when the energy threshold approaches the photon energy and when using charge summing. As a consequence, the contrast-to-noise ratio is found to double at elevated threshold levels and the dynamic range increases for a given counter depth. All these effects are shown to lead to an improved ability to perform material discrimination in spectroscopic CT, using iodine and gadolinium contrast agents. Hence, when compared to conventional photon counting detectors, these benefits carry the potential of substantially reducing the imaging dose a patient is exposed to during diagnostic CT examinations.


Subject(s)
Photoelectron Spectroscopy/methods , Photons , Radiography/methods , Photoelectron Spectroscopy/instrumentation , Radiography/instrumentation , Semiconductors , X-Rays
4.
Phys Med Biol ; 57(21): 6743-59, 2012 Nov 07.
Article in English | MEDLINE | ID: mdl-23032372

ABSTRACT

Spectroscopic x-ray imaging by means of photon counting detectors has received growing interest during the past years. Critical to the image quality of such devices is their pixel pitch and the sensor material employed. This paper describes the imaging properties of Medipix2 MXR multi-chip assemblies bump bonded to 1 mm thick CdTe sensors. Two systems were investigated with pixel pitches of 110 and 165 µm, which are in the order of the mean free path lengths of the characteristic x-rays produced in their sensors. Peak widths were found to be almost constant across the energy range of 10 to 60 keV, with values of 2.3 and 2.2 keV (FWHM) for the two pixel pitches. The average number of pixels responding to a single incoming photon are about 1.85 and 1.45 at 60 keV, amounting to detective quantum efficiencies of 0.77 and 0.84 at a spatial frequency of zero. Energy selective CT acquisitions are presented, and the two pixel pitches' abilities to discriminate between iodine and gadolinium contrast agents are examined. It is shown that the choice of the pixel pitch translates into a minimum contrast agent concentration for which material discrimination is still possible. We finally investigate saturation effects at high x-ray fluxes and conclude with the finding that higher maximum count rates come at the cost of a reduced energy resolution.


Subject(s)
Cadmium Compounds , Tellurium , Tomography, X-Ray Computed/methods , Contrast Media , Image Processing, Computer-Assisted , Phantoms, Imaging , Radiometry , Temperature , Water
SELECTION OF CITATIONS
SEARCH DETAIL
...